1. Mainpage
  2. Concrete screw in zinc flake with hexagonal head, induction hardened R-HLX-HF-ZF 8/10.4x100 mm - cardboard box - 100 pcs.

Concrete screw in zinc flake with hexagonal head, induction hardened R-HLX-HF-ZF 8/10.4x100 mm - cardboard box - 100 pcs.

Solid walls

R-HLX-08X100-HF-ZF

5906675556390

Induction hardened concrete screw anchor with hex head

Define product parameters:

Diameter
Length
Coating
Packaging and quantity
Weight and bulk packaging
  • Unit Pack Quantity

    4.97 kg

  • Bulk Pack Quantity

    4.97 kg

  • Pallet Quantity

    954.24 kg

Related products

Features

Induction hardened concrete screw anchor with hex head

  • The new thread geometry with additional cutting teeth ensures quick and easy installation, also in reinforced concrete C20/25 - C50/60.
  • Fire resistance R30-R120.
  • R-HLX concrete screws can be used in earthquake-prone zones - seismic category C1 and C2.
  • Special anti-corrosion zinc flake coating for increased corrosion resistance.
  • Possibility of installation near the edge of concrete and at short distances from adjacent screws.
  • Polish production guarantees the highest precision of workmanship and its repeatability.
  • Possibility of disassembly and repeated use after verifying thread wear with a tester.
  • The highest parameters in cracked and uncracked concrete C20/25 - C50/60 confirmed in the ETA.
  • Induction hardening ensures high surface hardness and high core impact strength.

Product video

Innowacyjny_wkret_do_betonu_hartowany_indukcyjnie_RHLX_Rawlplug_DLUGI

Rawlplug_Academy_czym_jest_i_jak_dziala_kotwa_mechaniczna

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Poles and road signs

Roads and bridges

Sanitary and gas installations

Scaffolding

Seats in public facilities

Steel structures

Storage racks

Full list of variations

Coating
Diameter
Length
Diameter
Length
Coating
Type of package
Pieces. per pack.
Index
EAN
10 mm100 mmZF - flake zinc

Cardboard box

50R-HLX-10X100-HF-ZF5906675533841

Contact with us and check out our terms of cooperation

12 mm150 mmZF - flake zinc

Cardboard box

50R-HLX-12X150-HF-ZF5906675533933

Contact with us and check out our terms of cooperation

12 mm110 mmZF - flake zinc

Cardboard box

50R-HLX-12X110-HF-ZF5906675533919

Contact with us and check out our terms of cooperation

10 mm80 mmZF - flake zinc

Cardboard box

50R-HLX-10X080-HF-ZF5906675533827

Contact with us and check out our terms of cooperation

10 mm70 mmZF - flake zinc

Cardboard box

50R-HLX-10X070-HF-ZF5906675533810

Contact with us and check out our terms of cooperation

12 mm70 mmZF - flake zinc

Cardboard box

50R-HLX-12X070-HF-ZF5906675533896

Contact with us and check out our terms of cooperation

12 mm90 mmZF - flake zinc

Cardboard box

50R-HLX-12X090-HF-ZF5906675533902

Contact with us and check out our terms of cooperation

10 mm120 mmZF - flake zinc

Cardboard box

25R-HLX-10X120-HF-ZF5906675533858

Contact with us and check out our terms of cooperation

8 mm100 mmZF - flake zinc

Cardboard box

100R-HLX-08X100-HF-ZF5906675556390

Contact with us and check out our terms of cooperation

8 mm75 mmZF - flake zinc

Cardboard box

100R-HLX-08X075-HF-ZF5906675556376

Contact with us and check out our terms of cooperation

Substitutes

Services

Rawlplug Academy

Rawlplug Academy

Design Consulting

Design Consulting

Design tools

Design tools

EasyFix

EasyFix

Installation guide

Installation manual

Installation step by step

1

Drill the hole with a hammer drill (1a) ) to the required depth according to the table

2

Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..

3

Screw the concrete screw into the hole with an impact wrench and a suitable impact socket. Tighten until the fixture is clamped to the substrate. Installation with any tangential impact wrench. Finish screwing when the screw head touches the fastened element/substrate. The screw head must not be damaged

4

Possibility to unscrew the fixed anchor to a maximum height of 10mm. In the adjustment process, the permissible thickness of the fastened elements (Tfix) must be observed

5

Finish screwing when the anchor touches the fastened element. The adjustment operation can be performed twice

Installation data

Approvals and publications

Technical library

(7)

Documents(7)

ETA-23/0707 (2025-01-24)

1488-CPR-1100/W (ETA-23/0707)

DoP-23/0707 R-HLX (ETA-23/0707)

VDS CEA 4001 (2025-03-05)

ETA-24/1104 (2025-06-03) - Non-structural systems

1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)

DoP-24/1104-R-HLX (ETA-24/1104 - Non-structural systems)

Catalogues and product cards

(1)

Product cards(1)

Product card

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2025 Koelner Rawlplug IP