1. Mainpage
  2. Epoxy bonded anchor R-KEX-II 3:1 - plastic cartouche - 385 ml

Epoxy bonded anchor R-KEX-II 3:1 - plastic cartouche - 385 ml

Solid walls

R-KEX-II-385

5906675028538

High-quality bonded anchor based on epoxy resin, approved for cracked concrete, as well as reinforced and unreinforced concrete

Define product parameters:

Bonded anchors version
Packaging and quantity
Weight and bulk packaging
  • Unit Pack Quantity

    6.71 kg

  • Bulk Pack Quantity

    6.71 kg

  • Pallet Quantity

    389.00 kg

Features

High-quality bonded anchor based on epoxy resin, approved for cracked concrete, as well as reinforced and unreinforced concrete

  • Approved for use with post-installed rebars concrete (EAD 330087-01-0601).
  • Approved for use in non-cracked concrete (EAD 330499-02-0601), working life up to 100 years.
  • Seismic approval for categories C1 and C2.
  • The extended open time allows bar insertion to the required depth even at high temperatures. The short curing time enables continuation of work on the same day.
  • Extended working time ensures easy installation.
  • Suitable for use in dry and wet substrates including under water.
  • High parameter stability at elevated temperatures.

Product video

rawlplug_rkexii_pure_e

Montaz_kotwy_chemicznej_obciazanie_ukladu

Czymjestkotwachemicznaijakjeju_ywa__

Rawlplug_Academy_jaki_otwor_pod_kotwe_chemiczna

Rawlplug_Academy_jak_wyczyscic_otwor_pod_kotwe_chemiczna

RKEM_II_Zapowiedz_jak_zamontowac_bojler_za_pomoca_kotwy_chemicznej

Rawlplug_Academy_bledy_montazu_kotwy_chemicznej

R_KEM_II_jak_zamontowa_bojler

Jak_kotw_chemiczn_wybra__

Jakprawid_owou_y_kotwychemicznej_

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Reinforced concrete

Reinforced concrete

Unreinforced concrete

Unreinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Anchoring glued in with reinforcing bars

Anchoring glued in with threaded rods

Concrete structures

Elevators and escalators

Roads and bridges

Steel structures

Full list of variations

Bonded anchors version
Packaging and quantity
Index
EAN
Catalog price for PC. net

Installation guide

Installation manual

Installation step by step

1

Drill a hole of appropriate diameter and depth.

2

Blow out the dust at least 4 times with the hand pump.

3

Remove drill cuttings in the hole using the brush four times.

4

Blow out the dust at least 4 times with the hand pump.

5

Insert cartridge into the gun and attach the nozzle.

6

​When beginning dispensing from a new cartouche, discard approximately 10 cm of resin to ensure thorough mixing of the components.

7

Fill the hole 70% with resin (follow the assembly instructions specific to the type of resin).

8

Immediately insert the rebar, slowly and with slight twisting motion. Remove any excess resin around the hole before it sets and leave it undisturbed until the curing time elapses.

9

Leave the anchor undisturbed unitl the curing time elapses.

10

Tighten to the recommended torque.

Approvals and publications

Technical library

(18)

Declarations(1)

DoP-13/0585 R-KEX-II (ETA-13/0585 - Rebar connections)

R-KEX II - Post-installed rebar connections with mortat

Certificates(1)

EPD_R-KEX-II

Documents(16)

ETA-21/0244 (2023-09-27) - Concrete

R-KEX II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

1488-CPR-0944/W (ETA-21/0244 - Concrete)

CPR - (ETA-21/0244 - Concrete) - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

DoP-21/0244 R-KEX-II (ETA-21/0244 - Concrete)

R-KEX II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

ETA-13/0585 (2023-09-25) - Rebar connections

R-KEX II - Post-installed rebar connections with mortar

1488-CPR-0737/W (ETA-13/0585 - Rebar connections)

CPR - (ETA-13/0585 - Rebar connections) - R-KEX II - Post-installed rebar connections with mortar

UKTA-0836-22/6132 - Concrete

UKTA-0836-22/6132 (2022-09-26) - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

UK 0836-CPR-23/P6744 - Concrete

UK 0836-CPR-23/P6744 (2023-02-23) - Bonded fasteners for use in concrete

UKTA-DoP-22/6132-R-KEXII - Concrete

UKTA-DoP-22/6132-R-KEXII - Bonded fasteners for use in concrete

UKTA-0836-22/6109 - Rebar connections

UKTA-0836-22/6109 (2022-05-31) - Post-installed rebar connections with injection mortar

UK 0836-CPR-23/P6743 - Rebar connections

UK 0836-CPR-23/P6743 - Post-installed rebar connections with injection mortar

UKTA-DoP-22/6109-R-KEXII - Rebar connections

UKTA-DoP-22/6109-R-KEXII - Post-installed rebar connections with injection mortar

KOT_2018_0134

IBDiM-KOT-2018/0134w2

KDWU_2018_0134_1

KDWU-2018-0134-2-SYSTEM RAWLPLUG

Hygienic certyficate - R-KEX II

B-BK-60111-0669/2023

VOC specification - R_KEXII

SDS R-KEX-II (2023-03-01)

MSDS

Catalogues and product cards

(6)

Product cards(4)

Product card

Product card

Product card

Product card

Catalogues(2)

Specification Design Guide

General Catalogue EN - PDF

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP