1. Mainpage
  2. R-LX Concrete Screw Anchor M6 / 7.5 x 40mm, Pan Head, Zinc Plated - cardboard box - 100 pcs.

Solid walls

R-LX-06X040-P-ZP

5906675034546

Zinc Plated Concrete Screw Anchor

Define product parameters:

Diameter
Length
Coating
Packaging and quantity
Weight and bulk packaging

Related products

Features

Zinc Plated Concrete Screw Anchor

  • Non-expansion functioning ensures low risk of damage to base material and makes R-LX ideal for installation near edges and adjacent anchors.
  • Completely removable with possibility of reuse.
  • Suitable for standard and reduced embedment depth.
  • High performance in both uncracked and cracked concrete.
  • Time-efficient through-fixing installation with streamlined procedure - simply drill and drive.
  • Unique design with patented threadform ensures high performance for relatively small hole diameter.
  • Excellent product for temporary fixing.
  • Oversize head for fixtures with elongated holes.
  • Different head types for any application.

kotwa_mechaniczna_01

Mechanical concrete screw anchor – Rawlplug's instruction

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Hollow-core slab C30/37-C50/60

Hollow-core slab C30/37-C50/60

High-density natural stone

High-density natural stone

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Approved surfaces

Balustrades

Concrete structures

Formwork

Gates

Scaffolding

Seats in public facilities

Storage racks

Temporary fixings

Diameter
Length
Coating
Packaging and quantity
Index
EAN
Catalog price for PAC. net

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Blow out the dust at least 4 times with the hand pump.

3

Tighten to specified installation torque.

4

After installation a further turning of the screw must not be possible. The head of the screw must be in contact with the substrate and is not damaged.

Installation data

Technical library

(4)

Technical assessments(1)

ETA-17/0806

Documents(3)

ETA 17/0783

DoP-17/0783 R-LX

UKTA-22/6346

Catalogues and product cards

(4)

Product cards(1)

Product cart

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN - PDF