1. Mainpage
  2. FX-L Hammer-in fixing with countersunk 8x100 mm - plastic bag - 50 pcs.

FX-L Hammer-in fixing with countersunk 8x100 mm - plastic bag - 50 pcs.

Solid walls

FKT-HAM050

5906675115603

Rawlplug

The hammer fixing for fast, simple, cost-effective installations

Define product parameters:

Diameter
Length
Packaging and quantity

We will prepare this product for you after you add it to your cart and place your order. The estimated lead time is 28 days

Related products

Features

The hammer fixing for fast, simple, cost-effective installations

  • The extensive range of product lengths and diameters with countersunk head type ensures availability of the correct fixing for every scenario
  • The extensive range of lengths and diameters mushroom head type plug ensures availability of the correct fixing for every scenario
  • Mushroom head
  • Combination of PZ recess and the helical thread makes removal of the nail possible, facilitating disassembly when necessary.
  • Nylon material for best quality
  • The extensive range of product lengths, diameters and head types ensures availability of the correct fixing for every scenario.
  • Designed for push-through installation.
  • Cylinder head prevents plug slipping into over-sized holes and allows fix thin elements
  • Rapid hammer-set installation reduces the time required and allows for cost-effective, high-volume installation.

Substrates

Concrete

Concrete

Aerated concrete

Aerated concrete

Solid brick

Solid brick

Lightweight concrete block

Lightweight concrete block

Solid sand-lime brick

Solid sand-lime brick

Hollow lightweight concrete block

Hollow lightweight concrete block

Hollow sand-lime brick

Hollow sand-lime brick

Approved surfaces

Applications

Electrical Installations

Frames, profiles, slats

Plasterboard systems

Plinths and finishing profiles

Profiled and cover sheets

Sanitary and gas installations

Services

Design Consulting

Design Consulting

Fleet of Power Tools

Fleet of Power Tools

Training at the Rawlplug Academy center

Training at the Rawlplug Academy center

Designing POS Displays

Designing POS Displays

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Blow out the dust at least 4 times with the hand pump.

3

Insert FX plug into the hole through fixture.

4

Hammer the nail into the plastic sleeve until fixing is secure and flush with the fixture.

5

The sleeve of the expansion plug is correctly attached.

6

Drill a hole to the required diameter and depth for rebar size being used.

7

Blow out the dust at least 4 times with the hand pump.

8

Place the screw in the sleeve through the fastened element.

9

Hammer the nail into the plastic sleeve until fixing is secure and flush with the fixture.

10

Pin is correctly fastened.

11

Drill a hole to the required diameter and depth for rebar size being used.

12

Blow out the dust at least 4 times with the hand pump.

13

Place the screw in the sleeve through the fastened element.

14

Hammer the nail into the plastic sleeve until fixing is secure and flush with the fixture.

15

Pin is correctly fastened.

Installation data

Approvals and publications

Technical library and approvals

Choose document:

ETA-13/0088

1488-CPR-0288/Z

DoP-13/0088 FX

KOT-2019/0762

020-UWB-0978/Z

KDWU-2019-0762-FX

Product card and catalogues

Choose product catalog:

Specification Design Guide

General catalogue - PDF

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2024 Koelner Rawlplug IP