1. Mainpage
  2. Products
  3. Fixings
  4. Roofing fixings
  5. Roofing sleeves with screws
  6. Telescopic sleeve with round plate R-GOK-II 50x085 mm PP + WX-48T060 - cardboard box - 300 pcs.

Telescopic sleeve with round plate R-GOK-II 50x085 mm PP + WX-48T060 - cardboard box - 300 pcs.

Steel

R-GOKII085WX48T060

5906675658674

Rawlplug

Pre-assembled telescopic fastening system for trapezoid sheet substrate

Define product parameters:

Length
Screw length
Packaging and quantity

We will prepare this product for you after you add it to your cart and place your order. The estimated lead time is 35 days

Features

Pre-assembled telescopic fastening system for trapezoid sheet substrate

  • High impact - resistant material used ensures constant mechanical properties over the lifetime of a roof. Also, retains its properties over a wide temperature range.
  • The lenticular shape of the plate ensures a firm pressure on the membrane and no possibility of dragging and deforming the plate during assembly.
  • The lower part of the connector telescope has been designed in the shape of a cone with an optimum angle of inclination which significantly affects the speed of its installation.
  • Internal sleeve design allows pre-assembly with any Rawlplug roofing screw, shortening installation.
  • Hardened screw's thread surface. High quality anti-corrosion coating guarantees resistance of 15 Kesternich cycles.
  • The shape and type of screw's thread is designed specifically for concrete substrate.
  • Reduced drilling point prevents the holes in thin metal sheets from being recalibrated.
  • The reduced diameter makes it easier to pierce the membrane and install in dense materials such as PIR / PUR and mineral wool.
  • Pre-assembled sleeve with a screw shortens the assembly time, additionally it has a security in the form of a locking O-ring, which prevents the screw from slipping out.
  • Guarantees the highest load capacity of the roof construction for both static and dynamic loads in accordance.

Substrates

Metal sheet & profiles

Metal sheet & profiles

Approved surfaces

Applications

Flat roofs

Full list of variations

Services

Installation guide

Installation manual

Installation step by step

1

Place the plastic sleeve R-GOK-II with the R-WX screw in the insulating material.

2

Using a driver, screw in the R-GOK-II connector with the R-WX screw until the appropriate depth is achieved.

3

Properly mounted sleeve R-GOK-II with R-WX screw.

Design data
SizeØ4.8Ø6.0
Thread diameterd[mm]
4,86,0
Min. substrate thickness - Steel sheethmin = t[mm]
0,630,63
Max. drilling capacitytI + tII[mm]
1,51,5
Min. edge distancecmin[mm]
4040
Min. spacingsmin[mm]
5050
Wrench size-[mm]
T25T25
SKUplastic_sleeve_lenght_L_mmplastic_sleeve_plate_diameter_D_mmr_wx_screw_diameter_d_2_mmr_wx_screw_length_L_2_mm85504,85050
85504,86060
105504,85050
105504,86060
105504,87070
105504,88080
135504,85050
135504,86060
135504,87070
165504,85050
165504,870
165504,880
185504,850
185504,860
185504,870
185504,880
185504,8100
225504,850
225504,860
225504,870
35504,860
Type of fixingR-WX-T 4,8R-WX-T 6,0
TENSION LOAD
CHARACTERISTIC RESISTANCE - STEEL DECK S280GD
Thickness of steel substructure tII = 0,63mmNRk[kN]
0,741,21
Thickness of steel substructure tII = 0,75mmNRk[kN]
1,001,34
Thickness of steel substructure tII = 0,88mmNRk[kN]
1,081,45
Thickness of steel substructure tII = 1,00mmNRk[kN]
1,501,88
Thickness of steel substructure tII = 1,25mmNRk[kN]
1,861,88
Thickness of steel substructure tII = 1,50mmNRk[kN]
1,881,88
Partial safety factorγM[-]
1,331,33
CHARACTERISTIC RESISTANCE - STEEL DECK S320GD
Thickness of steel substructure tII = 0,63mmNRk[kN]
0,801,31
Thickness of steel substructure tII = 0,75mmNRk[kN]
1,081,45
Thickness of steel substructure tII = 0,88mmNRk[kN]
1,171,57
Thickness of steel substructure tII = 1,00mmNRk[kN]
1,621,88
Thickness of steel substructure tII = 1,25mmNRk[kN]
1,881,88
Thickness of steel substructure tII = 1,50mmNRk[kN]
1,881,88
Partial safety factorγM[-]
1,331,33
CHARACTERISTIC RESISTANCE - STEEL DECK S350GD
Thickness of steel substructure tII = 0,63mmNRk[kN]
0,871,41
Thickness of steel substructure tII = 0,75mmNRk[kN]
1,161,56
Thickness of steel substructure tII = 0,88mmNRk[kN]
1,261,69
Thickness of steel substructure tII = 1,00mmNRk[kN]
1,741,88
Thickness of steel substructure tII = 1,25mmNRk[kN]
1,881,88
Thickness of steel substructure tII = 1,50mmNRk[kN]
1,881,88
Partial safety factorγM[-]
1,331,33

Approvals and publications

Technical library

(7)

Technical assessments(2)

ITB_KOT_2022_2206_2022_08_22_R_GOKII_R_POK_R_POW

ITB-KOT-2022/2206

ETA-23/0198

ETA-23/0198

Declarations(3)

KDWU-2022-2206-GOK-II

KDWU-2022-2206-GOK-II

KDWU_R_WX

KDWU-2022-2206-R-WX

DoP-23/0198-R-GOK-II

DoP-23/0198-R-GOK-II

Certificates(1)

1488-CPR-0697/Z

CPR

Documents(1)

FM approval PR465265 (2026-02-23)

R-GOK-II + R-WBT / R-WO / R-WX - Fasteners for flexible roof waterproofing systems

Catalogues and product cards

(4)

Product cards(1)

R-GOK-II + R-WX - Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP