| Type of fixing | R-WX-T 4,8 | R-WX-T 6,0 |
| TENSION LOAD |
| CHARACTERISTIC RESISTANCE - STEEL DECK S280GD |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,74 | 1,21 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,00 | 1,34 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,08 | 1,45 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,50 | 1,88 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | 1,86 | 1,88 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | 1,88 | 1,88 |
Partial safety factorγM[-] | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - STEEL DECK S320GD |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,80 | 1,31 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,08 | 1,45 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,17 | 1,57 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,62 | 1,88 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | 1,88 | 1,88 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | 1,88 | 1,88 |
Partial safety factorγM[-] | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - STEEL DECK S350GD |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,87 | 1,41 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,16 | 1,56 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,26 | 1,69 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,74 | 1,88 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | 1,88 | 1,88 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | 1,88 | 1,88 |
Partial safety factorγM[-] | 1,33 | 1,33 |