1. Mainpage
  2. Products
  3. Fixings
  4. Roofing fixings
  5. Roofing sleeves with screws
  6. Telescopic sleeve with round plate R-GOK-II 50x185 mm PP + WX-48T080 - cardboard box - 100 pcs.

Telescopic sleeve with round plate R-GOK-II 50x185 mm PP + WX-48T080 - cardboard box - 100 pcs.

Steel

R-GOKII185WX48T080

5906675530352

Rawlplug

Pre-assembled telescopic fastening system for trapezoid sheet substrate

Define product parameters:

Length
Screw length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.3.43 kg

  • Bulk pack

    100.00 pcs.3.43 kg

  • Pallet

    5600.00 pcs.192.19 kg

We will prepare this product for you after you add it to your cart and place your order. The estimated lead time is 7 days

Features

Pre-assembled telescopic fastening system for trapezoid sheet substrate

  • High impact - resistant material used ensures constant mechanical properties over the lifetime of a roof. Also, retains its properties over a wide temperature range.
  • The lenticular shape of the plate ensures a firm pressure on the membrane and no possibility of dragging and deforming the plate during assembly.
  • The lower part of the connector telescope has been designed in the shape of a cone with an optimum angle of inclination which significantly affects the speed of its installation.
  • Internal sleeve design allows pre-assembly with any Rawlplug roofing screw, shortening installation.
  • Hardened screw's thread surface. High quality anti-corrosion coating guarantees resistance of 15 Kesternich cycles.
  • The shape and type of screw's thread is designed specifically for concrete substrate.
  • Reduced drilling point prevents the holes in thin metal sheets from being recalibrated.
  • The reduced diameter makes it easier to pierce the membrane and install in dense materials such as PIR / PUR and mineral wool.
  • Pre-assembled sleeve with a screw shortens the assembly time, additionally it has a security in the form of a locking O-ring, which prevents the screw from slipping out.
  • Guarantees the highest load capacity of the roof construction for both static and dynamic loads in accordance.

Substrates

Metal sheet & profiles

Metal sheet & profiles

Approved surfaces

Applications

Flat roofs

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Place the plastic sleeve R-GOK-II with the R-WX screw in the insulating material.

2

Using a driver, screw in the R-GOK-II connector with the R-WX screw until the appropriate depth is achieved.

3

Properly mounted sleeve R-GOK-II with R-WX screw.

Design data
SizeØ4.8Ø6.0
Thread diameterd[mm]
4,86,0
Min. substrate thickness - Steel sheethmin = t[mm]
0,630,63
Max. drilling capacitytI + tII[mm]
1,51,5
Min. edge distancecmin[mm]
4040
Min. spacingsmin[mm]
5050
Wrench size-[mm]
T25T25
SKUplastic_sleeve_lenght_L_mmplastic_sleeve_plate_diameter_D_mmr_wx_screw_diameter_d_2_mmr_wx_screw_length_L_2_mm85504,85050
85504,86060
105504,85050
105504,86060
105504,87070
105504,88080
135504,85050
135504,86060
135504,87070
165504,85050
165504,870
165504,880
185504,850
185504,860
185504,870
185504,880
185504,8100
225504,850
225504,860
225504,870
35504,860
Type of fixingR-WX-T 4,8R-WX-T 6,0
TENSION LOAD
CHARACTERISTIC RESISTANCE - STEEL DECK S280GD
Thickness of steel substructure tII = 0,63mmNRk[kN]
0,741,21
Thickness of steel substructure tII = 0,75mmNRk[kN]
1,001,34
Thickness of steel substructure tII = 0,88mmNRk[kN]
1,081,45
Thickness of steel substructure tII = 1,00mmNRk[kN]
1,501,88
Thickness of steel substructure tII = 1,25mmNRk[kN]
1,861,88
Thickness of steel substructure tII = 1,50mmNRk[kN]
1,881,88
Partial safety factorγM[-]
1,331,33
CHARACTERISTIC RESISTANCE - STEEL DECK S320GD
Thickness of steel substructure tII = 0,63mmNRk[kN]
0,801,31
Thickness of steel substructure tII = 0,75mmNRk[kN]
1,081,45
Thickness of steel substructure tII = 0,88mmNRk[kN]
1,171,57
Thickness of steel substructure tII = 1,00mmNRk[kN]
1,621,88
Thickness of steel substructure tII = 1,25mmNRk[kN]
1,881,88
Thickness of steel substructure tII = 1,50mmNRk[kN]
1,881,88
Partial safety factorγM[-]
1,331,33
CHARACTERISTIC RESISTANCE - STEEL DECK S350GD
Thickness of steel substructure tII = 0,63mmNRk[kN]
0,871,41
Thickness of steel substructure tII = 0,75mmNRk[kN]
1,161,56
Thickness of steel substructure tII = 0,88mmNRk[kN]
1,261,69
Thickness of steel substructure tII = 1,00mmNRk[kN]
1,741,88
Thickness of steel substructure tII = 1,25mmNRk[kN]
1,881,88
Thickness of steel substructure tII = 1,50mmNRk[kN]
1,881,88
Partial safety factorγM[-]
1,331,33

Approvals and publications

Technical library

(7)

Technical assessments(2)

ITB_KOT_2022_2206_2022_08_22_R_GOKII_R_POK_R_POW

ITB-KOT-2022/2206

ETA-23/0198

ETA-23/0198

Declarations(3)

KDWU-2022-2206-GOK-II

KDWU-2022-2206-GOK-II

KDWU_R_WX

KDWU-2022-2206-R-WX

DoP-23/0198-R-GOK-II

DoP-23/0198-R-GOK-II

Certificates(1)

1488-CPR-0697/Z

CPR

Documents(1)

FM approval PR465265 (2026-02-23)

R-GOK-II + R-WBT / R-WO / R-WX - Fasteners for flexible roof waterproofing systems

Catalogues and product cards

(4)

Product cards(1)

R-GOK-II + R-WX - Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP