1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Concrete Screwbolts
  6. R-HLX High Performance Concrete Screwbolts
  7. Zinc plated internally threaded M6 concrete screw anchor R-HLX-I-ZP 6x35 mm - cardboard box - 100 pcs.

Zinc plated internally threaded M6 concrete screw anchor R-HLX-I-ZP 6x35 mm - cardboard box - 100 pcs.

Solid walls
New

R-HLX-06X35-I06-ZP

5906675557175

Hardened induction concrete screw with internal threaded head

Define product parameters:

Diameter
Length
Coating
Thread
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.2.38 kg

  • Bulk pack

    100.00 pcs.2.38 kg

  • Pallet

    38400.00 pcs.913.92 kg

Features

Hardened induction concrete screw with internal threaded head

  • The new thread geometry with additional cutting teeth ensures quick and easy installation, also in reinforced concrete C20/25 - C50/60.
  • Fire resistance R30-R120.
  • R-HLX concrete screws can be used in earthquake-prone zones - seismic category C1 and C2.
  • The internal thread allows for the use of standard metric screws or threaded rods, and for surface flush removal and reuse of the fixing point. This provides great flexibility.
  • Possibility of installation near the edge of concrete and at short distances from adjacent screws.
  • Polish production guarantees the highest precision of workmanship and its repeatability.
  • Possibility of disassembly and repeated use after verifying thread wear with a tester.
  • The highest parameters in cracked and uncracked concrete C20/25 - C50/60 confirmed in the ETA.
  • Induction hardening ensures high surface hardness and high core impact strength.

Product video

R-HLX High performed screwbolt

Innowacyjny_wkret_do_betonu_hartowany_indukcyjnie_RHLX_Rawlplug_KROTKI

Rawlplug Academy: czym jest i jak działa kotwa mechaniczna?

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Hollow-core slab C30/37-C50/60

Hollow-core slab C30/37-C50/60

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Balustrades

Formwork

Gates

Scaffolding

Seats in public facilities

Storage racks

Temporary fixings

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole with a hammer drill (1a) ) to the required depth according to the table

2

Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..

3

Screw the concrete screw into the hole using an impact wrench and the appropriate impact socket.

Installation data
Design data
Size68
Thread diameterd[mm]
7,910,4
Hole diameter in substrated0[mm]
68
Wrench sizeSw[mm]
1315
Internal threaddi[mm]
M6/M8/M10M12
Max. torque for impact screw driverTimp,max[Nm]
250350
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
6585
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfix
Min. installation depthhnom,s[mm]
5570
Min. substrate thicknesshmin,s[mm]
80110
Min. edge distancecmin[mm]
3535
Min. spacingsmin[mm]
3535
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
5070
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfix
Min. installation depthhnom,r[mm]
4060
Min. substrate thicknesshmin,r[mm]
80110
Min. edge distancecmin[mm]
3535
Min. spacingsmin[mm]
3535
MINIMUM EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
4560
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfix
Min. installation depthhnom,r[mm]
3550
Min. substrate thicknesshmin,r[mm]
80110
Min. edge distancecmin[mm]
3535
Min. spacingsmin[mm]
3535
Size68
Nominal ultimate tensile strengthfuk[N/mm2]
800800
Nominal yield strengthfyk[N/mm2]
640640
Cross sectional area As[mm2]
24,644,2
Elastic section modulusWel[mm3]
17,2441,42
Characteristic bending resistanceM0Rk,s[Nm]
16,639,8
Design bending resistanceM[Nm]
13,231,8
Size68
Standard embedment depthhnom[mm]
5570
Reduced embedment depthhnom[mm]
4060
Minimum embedment depthhnom[mm]
3550
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
UNCRACKED CONCRETE
Standard embedment depth-[kN]
18,9926,34
Reduced embedment depth-[kN]
11,0919,03
Minimum embedment depth-[kN]
8,3216,44
CRACKED CONCRETE
Standard embedment depth-[kN]
10,8812,24
Reduced embedment depth-[kN]
7,1111,59
Minimum embedment depth-[kN]
4,029,86
SHEAR LOAD VRu,m
UNCRACKED CONCRETE
Standard embedment depth-[kN]
10,6719,47
Reduced embedment depth-[kN]
10,6719,47
Minimum embedment depth-[kN]
8,9516,44
CRACKED CONCRETE
Standard embedment depth-[kN]
10,6719,47
Reduced embedment depth-[kN]
7,8119,47
Minimum embedment depth-[kN]
6,311,57
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
UNCRACKED CONCRETE
Standard embedment depth-[kN]
13,820,6
Reduced embedment depth-[kN]
813,87
Minimum embedment depth-[kN]
4,511,9
CRACKED CONCRETE
Standard embedment depth-[kN]
3,511
Reduced embedment depth-[kN]
29
Minimum embedment depth-[kN]
28
SHEAR LOAD VRk
UNCRACKED CONCRETE
Standard embedment depth-[kN]
9,717,7
Reduced embedment depth-[kN]
8,0817,7
Minimum embedment depth-[kN]
6,5211,98
CRACKED CONCRETE
Standard embedment depth-[kN]
9,717,7
Reduced embedment depth-[kN]
5,6617,7
Minimum embedment depth-[kN]
4,578,39
DESIGN RESISTANCE
TENSION LOAD NRd
UNCRACKED CONCRETE
Standard embedment depth-[kN]
9,213,73
Reduced embedment depth-[kN]
5,339,25
Minimum embedment depth-[kN]
37,93
CRACKED CONCRETE
Standard embedment depth-[kN]
2,337,33
Reduced embedment depth-[kN]
1,336
Minimum embedment depth-[kN]
1,335,33
SHEAR LOAD VRd
UNCRACKED CONCRETE
Standard embedment depth-[kN]
7,7614,16
Reduced embedment depth-[kN]
5,3914,16
Minimum embedment depth-[kN]
4,357,99
CRACKED CONCRETE
Standard embedment depth-[kN]
6,4714,16
Reduced embedment depth-[kN]
3,7712,95
Minimum embedment depth-[kN]
3,045,59
RECOMMENDED LOAD
TENSION LOAD Nrec
UNCRACKED CONCRETE
Standard embedment depth-[kN]
6,579,81
Reduced embedment depth-[kN]
3,816,61
Minimum embedment depth-[kN]
2,145,67
CRACKED CONCRETE
Standard embedment depth-[kN]
1,675,24
Reduced embedment depth-[kN]
0,954,29
Minimum embedment depth-[kN]
0,953,81
SHEAR LOAD Vrec
UNCRACKED CONCRETE
Standard embedment depth-[kN]
5,5410,11
Reduced embedment depth-[kN]
3,8510,11
Minimum embedment depth-[kN]
3,115,71
CRACKED CONCRETE
Standard embedment depth-[kN]
4,6210,11
Reduced embedment depth-[kN]
2,699,25
Minimum embedment depth-[kN]
2,173,99
Size68
Nominal embedment depthhnom[mm]
354055506070
Effective embedment depthhef[mm]
263043394356
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
19,419,419,435,435,435,4
Partial safety factorγMS[-]
1,51,51,51,51,51,5
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
4,5813,811,916,320,6
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN]
223,58911
Installation safety factorγinst[-]
1,01)1,01)1111
Increasing factors for concrete C30/37Ψc[-]
1,171,171,171,171,171,17
Increasing factors for concrete C40/50Ψc[-]
1,321,321,321,321,321,32
Increasing factors for concrete C50/60Ψc[-]
1,421,421,421,421,421,42
CONCRETE CONE FAILURE
Installation safety factorγinst[-]
1,01)1,01)1111
Factor for cracked concretekcr,N[-]
7,77,77,77,77,77,7
Factor for uncracked concretekucr,N[-]
111111111111
Spacingscr,N[mm]
7890129117129168
Edge distanceccr,N[mm]
394564,558,564,584
CONCRETE SPLITTING FAILURE
Installation safety factorγinst[-]
1,01)1,01)1111
Spacingscr,sp[mm]
8090130120150170
Edge distanceccr,sp[mm]
404565607585
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
9,79,79,717,717,717,7
Ductility factork7[-]
111111
Characteristic resistance with lever armMRk,s[Nm]
16,116,116,139,839,839,8
Partial safety factorγMS[-]
1,251,251,251,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
111122
Installation safety factorγinst[-]
111111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
354055506070
Anchor diameterdnom[mm]
666888
Installation safety factorγinst[-]
111111
1) Holes without cleaning γinst = 1,2
Size68
R (for EI) = 30 min
Nominal embedment depthhnom[mm]
354055506070
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,81,81,83,83,83,8
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,822,22,7
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,81,81,83,83,83,8
Characteristic resistance with lever armMRk,s[Nm]
1,51,51,54,34,34,3
R (for EI) = 60 min
Nominal embedment depthhnom[mm]
354055506070
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,41,41,42,92,92,9
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,822,22,7
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,41,41,42,92,92,9
Characteristic resistance with lever armMRk,s[Nm]
1,21,21,23,33,33,3
R (for EI) = 90 min
Nominal embedment depthhnom[mm]
354055506070
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
111222
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,822,22,7
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
111222
Characteristic resistance with lever armMRk,s[Nm]
0,80,80,82,32,32,3
R (for EI) = 120 min
Nominal embedment depthhnom[mm]
354055506070
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,80,80,81,61,61,6
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,40,40,71,61,82,2
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,80,80,81,61,61,6
Characteristic resistance with lever armMRk,s[Nm]
0,70,70,71,81,81,8
Size68
Nominal embedment depthhnom[mm]
4055506070
SEISMIC CATEGORY C1
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C1[kN]
19,419,435,435,435,4
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistance seismic C1NRk,p,C1[kN]
23,57,68,610,5
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C1[kN]
4,74,710,610,610,6
SEISMIC CATEGORY C2
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C2[kN]
----35,4
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistance seismic C2NRk,p,C2[kN]
----2
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C2[kN]
----3,6

Approvals and publications

Technical library

(8)

Technical assessments(2)

ETA-23/0707 (2025-01-24) - Cracked and uncracked concrete

R-HLX - Concrete screw for use in cracked and uncracked concrete

ETA-24/1104 (2025-06-03) - Non-structural systems

Concrete screw for use in concrete for redundant non-structural systems

Declarations(2)

DoP-23/0707 R-HLX (ETA-23/0707)

DoP-23/0707 R-HLX (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

DoP-24/1104-R-HLX (ETA-24/1104 - Non-structural systems)

R-HLX - Cpncrete screw for use in concrete for redundant non-structural systems.

Certificates(3)

1488-CPR-1100/W (ETA-23/0707)

CPR (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)

CPR - ETA-24/1104 (2025-06-03) - Non-structural systems

EPD-R-HLX (2025-11-27)

Type III Environmental Declaration Certificate

Documents(1)

VDS CEA 4001 (2025-03-05)

Pipe hanger components for automatic sprinkler systems

Catalogues and product cards

(5)

Product cards(2)

Product card

Product card R-HLX hollow-core slab

Catalogues(3)

Catalogue Offer (overview) - EN

General Catalogue EN 2026/27

Specification Design Guide

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP