1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Concrete Screwbolts
  6. R-HLX High Performance Concrete Screwbolts
  7. R-HLX Concrete Screw Anchor M10 / 12.4 x 200mm, Hex Flange, Zinc Flake, ETA-23/0707 - cardboard box - 20 pcs.

R-HLX Concrete Screw Anchor M10 / 12.4 x 200mm, Hex Flange, Zinc Flake, ETA-23/0707 - cardboard box - 20 pcs.

Solid walls
New

R-HLX-10X200-HF-ZF

5906675533889

Induction hardened concrete screw anchor with hex head

Define product parameters:

Diameter
Length
Coating
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    20.00 pcs.2.91 kg

  • Bulk pack

    20.00 pcs.2.91 kg

  • Pallet

    6000.00 pcs.873.00 kg

Features

Induction hardened concrete screw anchor with hex head

  • The new thread geometry with additional cutting teeth ensures quick and easy installation, also in reinforced concrete C20/25 - C50/60.
  • Fire resistance R30-R120.
  • R-HLX concrete screws can be used in earthquake-prone zones - seismic category C1 and C2.
  • Special anti-corrosion zinc flake coating for increased corrosion resistance.
  • Possibility of installation near the edge of concrete and at short distances from adjacent screws.
  • Polish production guarantees the highest precision of workmanship and its repeatability.
  • Possibility of disassembly and repeated use after verifying thread wear with a tester.
  • The highest parameters in cracked and uncracked concrete C20/25 - C50/60 confirmed in the ETA.
  • Induction hardening ensures high surface hardness and high core impact strength.

Product video

R-HLX High performed screwbolt

Rawlplug Academy: czym jest i jak działa kotwa mechaniczna?

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Roads and bridges

Sanitary and gas installations

Scaffolding

Seats in public facilities

Steel structures

Storage racks

Balustrades

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole with a hammer drill (1a) ) to the required depth according to the table

2

Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..

3

Screw the concrete screw into the hole with an impact wrench and a suitable impact socket. Tighten until the fixture is clamped to the substrate. Installation with any tangential impact wrench. Finish screwing when the screw head touches the fastened element/substrate. The screw head must not be damaged

4

Possibility to unscrew the fixed anchor to a maximum height of 10mm. In the adjustment process, the permissible thickness of the fastened elements (Tfix) must be observed

5

Finish screwing when the anchor touches the fastened element. The adjustment operation can be performed twice

Installation data
Design data
Size68101214
Thread diameterd[mm]
7,910,412,714,916,9
Hole diameter in substrated0[mm]
68101214
Hole diameter in fixturedf[mm]
912141618
Wrench sizeSw[mm]
1013151721
External diameter of washerd[mm]
14,218,52126,631,7
Max. torque for impact screw driverTimp,max[Nm]
25035065010001000
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
658595110125
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfixL+10-tfixL+10-tfixL+10-tfix
Min. installation depthhnom,s[mm]
557085100115
Min. substrate thicknesshmin,s[mm]
80110130155190
Min. edge distancecmin[mm]
35356080100
Min. spacingsmin[mm]
35356080100
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
5070859095
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfixL+10-tfixL+10-tfixL+10-tfix
Min. installation depthhnom,r[mm]
4060758085
Min. substrate thicknesshmin,r[mm]
80110120130130
Min. edge distancecmin[mm]
35356080100
Min. spacingsmin[mm]
35356080100
MINIMUM EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
4560657075
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfixL+10-tfixL+10-tfixL+10-tfix
Min. installation depthhnom,r[mm]
3550556065
Min. substrate thicknesshmin,r[mm]
80110100110110
Min. edge distancecmin[mm]
35356080100
Min. spacingsmin[mm]
35356080100
Size68101214
Nominal ultimate tensile strengthfuk[N/mm2]
800800800800800
Nominal yield strengthfyk[N/mm2]
640640640640640
Cross sectional area As[mm2]
24,644,267,9103,9138,9
Elastic section modulusWel[mm3]
17,2441,4275,97149,31230,97
Characteristic bending resistanceM0Rk,s[Nm]
16,639,875,8143,3221,7
Design bending resistanceM[Nm]
13,231,860,6114,7177,4
Size68101214
Standard embedment depthhnom[mm]
557085100115
Reduced embedment depthhnom[mm]
4060758085
Minimum embedment depthhnom[mm]
3550556065
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
UNCRACKED CONCRETE
Standard embedment depth-[kN]
18,9926,3437,8548,359,56
Reduced embedment depth-[kN]
11,0919,0330,5933,7536,19
Minimum embedment depth-[kN]
8,3216,4418,3721,0623,15
CRACKED CONCRETE
Standard embedment depth-[kN]
10,8812,2426,6433,9941,92
Reduced embedment depth-[kN]
7,1111,5921,5323,7525,47
Minimum embedment depth-[kN]
4,029,8612,9314,8216,29
SHEAR LOAD VRu,m
UNCRACKED CONCRETE
Standard embedment depth-[kN]
10,6719,4729,9245,7661,16
Reduced embedment depth-[kN]
10,6719,4729,9245,7661,16
Minimum embedment depth-[kN]
8,9516,4418,3742,1246,31
CRACKED CONCRETE
Standard embedment depth-[kN]
10,6719,4729,9245,7661,16
Reduced embedment depth-[kN]
7,8119,4729,9245,7650,94
Minimum embedment depth-[kN]
6,311,5712,9329,6432,59
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
UNCRACKED CONCRETE
Standard embedment depth-[kN]
13,820,627,5835,243,4
Reduced embedment depth-[kN]
813,8722,2924,626,38
Minimum embedment depth-[kN]
4,511,913,3915,3516,87
CRACKED CONCRETE
Standard embedment depth-[kN]
3,51119,324,630,39
Reduced embedment depth-[kN]
2915,617,218,46
Minimum embedment depth-[kN]
289,3710,711,8
SHEAR LOAD VRk
UNCRACKED CONCRETE
Standard embedment depth-[kN]
9,717,727,241,655,6
Reduced embedment depth-[kN]
8,0817,727,241,652,75
Minimum embedment depth-[kN]
6,5211,9813,3930,733,75
CRACKED CONCRETE
Standard embedment depth-[kN]
9,717,727,241,655,6
Reduced embedment depth-[kN]
5,6617,727,234,4436,93
Minimum embedment depth-[kN]
4,578,399,3721,4923,62
DESIGN RESISTANCE
TENSION LOAD NRd
UNCRACKED CONCRETE
Standard embedment depth-[kN]
9,213,7318,3923,4728,93
Reduced embedment depth-[kN]
5,339,2514,8616,417,58
Minimum embedment depth-[kN]
37,938,9310,2311,25
CRACKED CONCRETE
Standard embedment depth-[kN]
2,337,3312,8716,420,26
Reduced embedment depth-[kN]
1,33610,411,4712,31
Minimum embedment depth-[kN]
1,335,336,257,137,87
SHEAR LOAD VRd
UNCRACKED CONCRETE
Standard embedment depth-[kN]
7,7614,1621,7633,2844,48
Reduced embedment depth-[kN]
5,3914,1621,7632,835,17
Minimum embedment depth-[kN]
4,357,998,9320,4622,5
CRACKED CONCRETE
Standard embedment depth-[kN]
6,4714,1621,7632,8540,52
Reduced embedment depth-[kN]
3,7712,9520,8122,9624,62
Minimum embedment depth-[kN]
3,045,596,2514,3215,75
RECOMMENDED LOAD
TENSION LOAD Nrec
UNCRACKED CONCRETE
Standard embedment depth-[kN]
6,579,8113,1416,7620,67
Reduced embedment depth-[kN]
3,816,6110,6211,7112,56
Minimum embedment depth-[kN]
2,145,676,387,318,03
CRACKED CONCRETE
Standard embedment depth-[kN]
1,675,249,1911,7114,47
Reduced embedment depth-[kN]
0,954,297,438,198,79
Minimum embedment depth-[kN]
0,953,814,465,15,62
SHEAR LOAD Vrec
UNCRACKED CONCRETE
Standard embedment depth-[kN]
5,5410,1115,5423,7731,77
Reduced embedment depth-[kN]
3,8510,1115,5423,4325,12
Minimum embedment depth-[kN]
3,115,716,3814,6216,07
CRACKED CONCRETE
Standard embedment depth-[kN]
4,6210,1115,5423,4728,94
Reduced embedment depth-[kN]
2,699,2514,8616,417,58
Minimum embedment depth-[kN]
2,173,994,4610,2311,25
Size68101214
Nominal embedment depthhnom[mm]
35405550607055758560801006585115
Effective embedment depthhef[mm]
263043394356425968466380496692
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
19,419,419,435,435,435,454,354,354,383,183,183,1111,1111,1111,1
Partial safety factorγMS[-]
1,51,51,51,51,51,51,51,51,51,51,51,51,51,51,5
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
4,5813,811,916,320,613,422,327,615,424,635,216,926,443,4
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN]
223,589119,415,619,310,717,224,611,818,530,4
Installation safety factorγinst[-]
1,01)1,01)1111111111111
Increasing factors for concrete C30/37Ψc[-]
1,171,171,171,171,171,171,221,221,221,221,221,221,221,221,22
Increasing factors for concrete C40/50Ψc[-]
1,321,321,321,321,321,321,411,411,411,411,411,411,411,411,41
Increasing factors for concrete C50/60Ψc[-]
1,421,421,421,421,421,421,551,551,551,551,551,551,551,551,55
CONCRETE CONE FAILURE
Installation safety factorγinst[-]
1,01)1,01)1111111111111
Factor for cracked concretekcr,N[-]
7,77,77,77,77,77,77,77,77,77,77,77,77,77,77,7
Factor for uncracked concretekucr,N[-]
111111111111111111111111111111
Spacingscr,N[mm]
7890129117129168126177204138189240147198276
Edge distanceccr,N[mm]
394564,558,564,5846388,51026994,512073,599138
CONCRETE SPLITTING FAILURE
Installation safety factorγinst[-]
1,01)1,01)1111111111111
Spacingscr,sp[mm]
8090130120150170120180200140200240150200280
Edge distanceccr,sp[mm]
40456560758560901007010012075100140
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
9,79,79,717,717,717,727,227,227,241,641,641,655,655,655,6
Ductility factork7[-]
111111111111111
Characteristic resistance with lever armMRk,s[Nm]
16,116,116,139,839,839,875,875,875,8143,4143,4143,4221,7221,7221,7
Partial safety factorγMS[-]
1,251,251,251,251,251,251,251,251,251,251,251,251,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
111122122222222
Installation safety factorγinst[-]
111111111111111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
35405550607055758560801006585115
Anchor diameterdnom[mm]
666888101010121212141414
Installation safety factorγinst[-]
111111111111111
1) Holes without cleaning γinst = 1,2
Size68101214
R (for EI) = 30 min
Nominal embedment depthhnom[mm]
35405550607055758560801006585115
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,81,81,83,83,83,86,66,66,611,411,411,415,215,215,2
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,822,22,72,33,94,82,64,36,12,94,67,6
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,81,81,83,83,83,86,66,66,611,411,411,415,215,215,2
Characteristic resistance with lever armMRk,s[Nm]
1,51,51,54,34,34,39,39,39,319,719,719,730,430,430,4
R (for EI) = 60 min
Nominal embedment depthhnom[mm]
35405550607055758560801006585115
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,41,41,42,92,92,95558,58,58,511,411,411,4
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,822,22,72,33,94,82,64,36,12,94,67,6
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,41,41,42,92,92,95558,58,58,511,411,411,4
Characteristic resistance with lever armMRk,s[Nm]
1,21,21,23,33,33,377714,814,814,822,922,922,9
R (for EI) = 90 min
Nominal embedment depthhnom[mm]
35405550607055758560801006585115
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1112223,43,43,45,75,75,77,67,67,6
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,822,22,72,33,94,82,64,36,12,94,67,6
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1112223,43,43,45,75,75,77,67,67,6
Characteristic resistance with lever armMRk,s[Nm]
0,80,80,82,32,32,34,84,84,89,99,99,915,315,315,3
R (for EI) = 120 min
Nominal embedment depthhnom[mm]
35405550607055758560801006585115
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,80,80,81,61,61,62,62,62,64,34,34,35,75,75,7
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,40,40,71,61,82,21,83,13,82,13,44,92,33,66
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,80,80,81,61,61,62,62,62,64,34,34,35,75,75,7
Characteristic resistance with lever armMRk,s[Nm]
0,70,70,71,81,81,83,73,73,77,47,47,411,511,511,5
Size68101214
Nominal embedment depthhnom[mm]
405550607055758560801006585115
SEISMIC CATEGORY C1
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C1[kN]
19,419,435,435,435,454,354,354,383,183,183,1111,1111,1111,1
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistance seismic C1NRk,p,C1[kN]
23,57,68,610,58,614,417,87,612,217,58,413,121,6
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C1[kN]
4,74,710,610,610,618,718,718,728,728,728,738,338,338,3
SEISMIC CATEGORY C2
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C2[kN]
----35,4--54,3--83,1--111,1
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistance seismic C2NRk,p,C2[kN]
----2--8,5--13,3--19,3
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C2[kN]
----3,6--8--22,3--21,6

Approvals and publications

Technical library

(14)

Technical assessments(4)

ETA-23/0707 (2025-01-24) - Cracked and uncracked concrete

R-HLX - Concrete screw for use in cracked and uncracked concrete

ETA-24/1104 (2025-06-03) - Non-structural systems

Concrete screw for use in concrete for redundant non-structural systems

KOT-2020/1559

ITB-KOT-2020/1559

ETA26_0257_PL

ETA 26-0257 (2026-06-28)

Declarations(4)

DoP-23/0707 R-HLX (ETA-23/0707)

DoP-23/0707 R-HLX (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

DoP-24/1104-R-HLX (ETA-24/1104 - Non-structural systems)

R-HLX - Cpncrete screw for use in concrete for redundant non-structural systems.

KDWU_ITB_KOT_2020_1559_2020_12_10w1_WBT

KDWU-2020-1559-2-WBT

DoP-26/0257-R-HLX (ETA 26/0257)

DoP-26/0257-R-HLX

Certificates(5)

1488-CPR-1100/W (ETA-23/0707)

CPR (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)

CPR - ETA-24/1104 (2025-06-03) - Non-structural systems

EPD-R-HLX (2025-11-27)

Type III Environmental Declaration Certificate

020_UWB_1270_Z

020-UWB-1270/Z

1488_CPR_1261_W_PL

1488-CPR-1261/W

Documents(1)

VDS CEA 4001 (2025-03-05)

Pipe hanger components for automatic sprinkler systems

Catalogues and product cards

(7)

Product cards(3)

Product card

Product card R-HLX hollow-core slab

Product card R-HLX concrete-to-concrete connections

Catalogues(4)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

KATALOG_DROGI_I_MOSTY_PL

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP