Throughbolt anchor with corrosion-resistant coating for cracked and non-cracked concrete

Define product parameters:

Diameter
Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    50.00 pcs.2.37 kg

  • Bulk pack

    50.00 pcs.2.37 kg

  • Pallet

    8000.00 pcs.379.36 kg

Features

Throughbolt anchor with corrosion-resistant coating for cracked and non-cracked concrete

  • Anchors can be used in earthquake risk zones - seismic category C1 and C2.
  • Design of R-HPTII allows drilling and installing directly through the fixture and helps to reduce installation time.
  • New generation of throughbolt with unique corrosion-resistant coating.
  • Fire resistant.
  • For applications requiring fire resistance up to 120 minutes.
  • Highest quality ensures maximum load capability.
  • Embedment depth markings help to ensure precise installation of the anchor.
  • High performance in cracked and non-cracked concrete confirmed by ETA Option 1.
  • Suitable for reduced embedment to avoid contact with reinforcement.

Product video

rawlplug_rhptiizf_zinc

Rawlplug Academy: czym jest i jak działa kotwa mechaniczna?

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Balustrades

Brackets

Elevators and escalators

Gates

Steel structures

Storage racks

Ventilated facades

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Blow out the dust at least 4 times with the hand pump.

3

Insert the anchor into the hole through the fastening element and tap it with a hammer to the appropriate depth

4

Using a torque wrench, tighten the nut to the required torque

5

The anchor is installed correctly

Installation data
Design data
SizeM8M10M12M16M20
Thread diameterd[mm]
810121620
Hole diameter in substrated0[mm]
810121620
Hole diameter in fixturedf[mm]
911131822
Installation torqueTinst[Nm]
102040100180
Wrench sizeSw[mm]
1317192430
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
657990110129
Min. installation depthhnom,s[mm]
556980100119
Min. substrate thicknesshmin,s[mm]
100120140170200
Min. spacing (Uncracked concrete)smin,s[mm]
507090160180
Min. spacing (Cracked concrete)smin,s[mm]
507090160180
Min. edge distance (Uncracked concrete)cmin,s[mm]
40506585100
Min. edge distance (Cracked concrete)cmin,s[mm]
40456590100
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
50597090110
Min. installation depthhnom,r[mm]
401)491)6080100
Min. substrate thicknesshmin,r[mm]
100100100130160
Min. spacing (Uncracked concrete)smin,r[mm]
5575150190300
Min. spacing (Cracked concrete)smin,r[mm]
5575150190300
Min. edge distance (Uncracked concrete)cmin,r[mm]
456070100160
Min. edge distance (Cracked concrete)cmin,r[mm]
405080110120
1) Use restricted to anchoring statically indeterminate structural components
SizeM8M10M12M16M20
Nominal ultimate tensile strengthfuk[N/mm2]
620620620620620
Nominal yield strengthfyk[N/mm2]
531531531531531
Cross sectional area As[mm2]
25,540,760,1106,6162,9
Elastic section modulusWel[mm3]
34,368,3119,6229,5588,3
Characteristic bending resistanceM0Rk,s[Nm]
224579200389
Design bending resistanceM[Nm]
17,63663,2160311,2
SizeM8M10M12M16M20
Standard embedment depthhef[mm]
4759688599
Reduced embedment depthhef[mm]
321)391)486580
MEAN ULTIMATE RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRu,m[kN]
12,420,627,745,564,8
Reduced embedment depthNRu,m[kN]
9,613,617,634,547,1
CRACKED CONCRETE
Standard embedment depthNRu,m[kN]
7,512,519,927,341,9
Reduced embedment depthNRu,m[kN]
4,88,612,826,832,7
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRu,m[kN]
12,219,22851,580,9
Reduced embedment depthVRu,m[kN]
10,116,4422,4551,580,9
CRACKED CONCRETE
Standard embedment depthVRu,m[kN]
12,219,22851,580,9
Reduced embedment depthVRu,m[kN]
8,611,5715,849,7866,66
CHARACTERISTIC RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRk[kN]
912203548,46
Reduced embedment depthNRk[kN]
7,591225,7835,2
CRACKED CONCRETE
Standard embedment depthNRk[kN]
59122030
Reduced embedment depthNRk[kN]
3691624,64
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRk[kN]
9,115,723,747,160,6
Reduced embedment depthVRk[kN]
8,911,9816,3647,160,6
CRACKED CONCRETE
Standard embedment depthVRk[kN]
9,115,6123,747,160,6
Reduced embedment depthVRk[kN]
6,238,3911,4536,0949,28
DESIGN RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRd[kN]
5813,3323,3332,3
Reduced embedment depthNRd[kN]
4,175817,1923,47
CRACKED CONCRETE
Standard embedment depthNRd[kN]
2,786813,3320
Reduced embedment depthNRd[kN]
1,673,33610,6716,43
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRd[kN]
7,2812,5618,9637,6848,48
Reduced embedment depthVRd[kN]
5,947,9910,9134,3746,93
CRACKED CONCRETE
Standard embedment depthVRd[kN]
7,2810,418,9635,9845,23
Reduced embedment depthVRd[kN]
4,165,597,6324,0632,85
RECOMMENDED LOAD
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNrec[kN]
3,575,719,5216,6623,07
Reduced embedment depthNrec[kN]
2,983,575,7112,2816,76
CRACKED CONCRETE
Standard embedment depthNrec[kN]
1,994,295,719,5214,29
Reduced embedment depthNrec[kN]
1,192,384,297,6211,74
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVrec[kN]
5,28,9713,5426,9134,63
Reduced embedment depthVrec[kN]
4,245,717,7924,5533,52
CRACKED CONCRETE
Standard embedment depthVrec[kN]
5,27,4313,5425,732,31
Reduced embedment depthVrec[kN]
2,973,995,4517,1923,46
1) Use restricted to anchoring statically indeterminate structural components
SizeM8M10M12M16M20
Nominal embedment depthhnom[mm]
401)55491)69608080100100119
Effective embedment depthhef[mm]
321)47391)59486865858099
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
111117,517,525,825,845,845,87070
Partial safety factorγMS[-]
1,41,41,41,41,41,41,41,41,41,4
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
7,599121220-35--
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN]
35699121620-30
Installation safety factorγinst[-]
1,21,21,21111111
Increasing factors for concrete C30/37Ψc[-]
1,21,121,161,221,2211,111,141,121,07
Increasing factors for concrete C40/50Ψc[-]
1,41,221,331,441,4411,221,281,261,14
Increasing factors for concrete C50/60Ψc[-]
1,61,331,51,671,6711,331,431,391,21
CONCRETE CONE FAILURE
Installation safety factorγinst[-]
1,21,21,21111111
Factor for uncracked concretekucr,N[-]
11111111111111111111
Factor for cracked concretekcr,N[-]
7,77,77,77,77,77,77,77,77,77,7
Spacingscr,N[mm]
96141117177144204195255240297
Edge distanceccr,N[mm]
487159897210298128120149
CONCRETE SPLITTING FAILURE
Spacingscr,N[mm]
170220200300250340320430410530
Edge distanceccr,N[mm]
85110100150125170160215205265
Installation safety factorγinst[-]
1,21,21,21111111
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armV0Rk,s[kN]
9,19,115,715,723,723,747,147,160,660,6
Ductility factork7[-]
0,80,80,80,80,80,80,80,80,80,8
Characteristic resistance with lever armMRk,s[Nm]
222245457979200200389389
Partial safety factorγMS[-]
1,251,251,251,251,251,251,251,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
1111122222
Installation safety factorγinst[-]
1111111111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
32473959486865858099
Anchor diameterdnom[mm]
881010121216162020
Installation safety factorγinst[-]
1111111111
1) Use restricted to anchoring statically indeterminate structural components
(-) failure is not decisive
SizeM8M10M12M16M20
Effective embedment depthhef[mm]
321)47391)59486865858099
R (for EI) = 30 min
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,40,40,90,91,71,73,13,14,94,9
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,81,31,52,32,3345--
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,40,40,90,91,71,73,13,14,94,9
Characteristic resistance with lever armMRk,s[Nm]
0,40,41,11,12,62,66,76,71313
R (for EI) = 60 min
Effective embedment depthhef[mm]
321)47391)59486865858099
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,30,30,80,81,31,32,42,43,73,7
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,81,31,52,32,3345--
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,30,30,80,81,31,32,42,43,73,7
Characteristic resistance with lever armMRk,s[Nm]
0,30,31122559,79,7
R (for EI) = 90 min
Effective embedment depthhef[mm]
321)47391)59486865858099
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,30,30,60,61,11,1223,23,2
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,81,31,52,32,3345--
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,30,30,60,61,11,1223,23,2
Characteristic resistance with lever armMRk,s[Nm]
0,30,30,70,71,71,74,34,38,48,4
R (for EI) = 120 min
Effective embedment depthhef[mm]
321)47391)59486865858099
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,20,20,50,50,80,81,61,62,52,5
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,611,21,81,82,43,24--
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,20,20,50,50,80,81,61,62,52,5
Characteristic resistance with lever armMRk,s[Nm]
0,20,20,60,61,31,33,33,36,56,5
1) Use restricted to anchoring statically indeterminate structural components
* In absence of other national regulations the partial safety factor for resistance under fire exposure. γM,fi = 1,0 is recommended
SizeM10M12M16
Effective embedment depthhef[mm]
596885
SEISMIC CATEGORY C2
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C2[kN]
17,525,845,8
Partial safety factorγMsN,seisC2[-]
1,41,41,4
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistanceNRk,p,C2[kN]
3,4710,9
Installation safety factorγinst[-]
111
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C2[kN]
9,211,128,2
Partial safety factorγMsV,seisC2[-]
1,251,251,25

Approvals and publications

Technical library

(6)

Technical assessments(2)

ETA-17/0184 (2023-11-09)

R-HPTII-ZF - Torque controlled expansion anchor for use in cracked and uncracked concrete

UKTA-22/6202 (2022-11-11)

Torque controlled expansion anchor for use in cracked and uncracked concrete.

Declarations(2)

DoP-17/0184 R-HPTII-ZF (ETA-17/0184)

DoP-17/0184 R-HPTII-ZF (ETA-17/0184 - 2023-11-09) - Torque controlled expansion anchor for use in cracked and uncracked concrete

UKTA-DoP-22/6202 R-HPTII-ZF (2022-11-11)

R-HPTII-ZF - Expansion anchor for use in cracked and uncracked concrete.

Certificates(2)

1488-CPR-0629/W (ETA-17/0184)

CPR (ETA-17/0184 - 2023-11-09) - Torque controlled expansion anchor for use in cracked and uncracked concrete.

UK 0836-CPR-23/P6741 (2023-02-23)

UK 0836-CPR-23/P6741

Catalogues and product cards

(4)

Product cards(1)

Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP