1. Mainpage
  2. KI-10 Hammer-in facade fixing with plastic pin 10x180 mm - cardboard box - 250 pcs.

Universal

R-KI-180

5906675258225

Rawlplug

Hammer-in facade fixing with reinforced plastic nail

Define product parameters:

Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    250.00 pcs.4.50 kg

  • Bulk pack

    250.00 pcs.4.50 kg

  • Pallet

    7500.00 pcs.135.00 kg

Related products

Features

Hammer-in facade fixing with reinforced plastic nail

  • Installation in all base materials (categories A,B,C,D,E).
  • The plastic nail reduces heat transmission (value 0.0 W/K).
  • Plastic nail reinforced with glass fibre allows fast and trouble-free installation with correct expansion of the plug.
  • Expansion zone designed for low embedment depths, reducing the amount of drilling required.
  • Can be used with additional KWL insulation holding plate, available in 90, 110 and 140 mm flange sizes (recommended for soft insulation materials such as mineral wool).
  • Optimal product parameters enable cost-saving solutions.
  • Optimum plate stiffness (0,5 kN/mm), ensures stability and excellent pull-over values.

Concrete ≥ C12/15 (Use category A)

Concrete ≥ C12/15 (Use category A)

Solid brick (B)

Solid brick (B)

Solid sand-lime brick (B)

Solid sand-lime brick (B)

Vertically-perforated clay block (C)

Vertically-perforated clay block (C)

Hollow sand-lime brick (C)

Hollow sand-lime brick (C)

Lightweight concrete block

Lightweight concrete block

Hollow lightweight concrete block (D)

Hollow lightweight concrete block (D)

Lightweight concrete

Lightweight concrete

Aerated concrete block (D)

Aerated concrete block (D)

Approved surfaces

Ventilated facades

Facades - thermal insulation systems

Length
Packaging and quantity
Index
EAN
Catalog price for pack. net

Installation manual

Installation step by step

1

Drill a hole of required diameter and depth.

2

Lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached.

3

Lightly tap the plastic nail into the plastic sleeve until fixing is secure and flush with insulation material. Embedment depth of min 25 mm in masonry, 40 mm in perforated materials and 60 mm in lightweight concrete block and aerated concrete.

4

In soft insulation panels the fixing should be combined with insulation retaining plates KWL 90, 110, 140 mm.

Installation data

Technical library

(5)

Technical assessments(2)

ETA-07/0291 (2022-04-19)

UKTA-22/6369 (2022-11-11)

Declarations(2)

DoP-07/0291 KI-10 (ETA-07/0291)

UKTA-DoP-22/6369-KI-10 (2023-10-02)

Certificates(1)

1488-CPR-0368/Z (ETA-07/0291)

Catalogues and product cards

(3)

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27 - PDF