| R-OCFC 4,8 x L | | | | |
Thickness of metal member or sheetingtI[mm] | 0,40 | 0,50 | 0,63 | 0,75 | 1,00 |
| TENSION LOAD |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCFC 4,8 without washer) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,64 | 0,64 | 0,64 | 0,64 | 0,64 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,67 | 0,67 | 0,67 | 0,67 | 0,67 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,93 | 0,93 | 0,93 | 0,93 | 0,93 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,18 | 1,43 | 1,43 | 1,43 | 1,43 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,18 | 1,39 | 1,67 | 1,81 | 1,81 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCFC 4,8 with washer ≥ Ø14) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,64 | 0,64 | 0,64 | 0,64 | 0,64 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,67 | 0,67 | 0,67 | 0,67 | 0,67 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,93 | 0,93 | 0,93 | 0,93 | 0,93 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,43 | 1,43 | 1,43 | 1,43 | 1,43 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,45 | 1,81 | 1,81 | 1,81 | 1,81 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCFC 4,8 without washer) |
Characteristic resistanceNRk,I,k[kN] | 1,18 | 1,39 | 1,67 | 2,07 | 3,56 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCFC 4,8 with washer ≥ Ø14) |
Characteristic resistanceNRk,I,k[kN] | 1,45 | 2,04 | 2,52 | 2,65 | 2,65 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - PULL-OUT FAILURE (screw R-OCFC 4,8 without or with washer ≥ Ø14) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,64 | 0,64 | 0,64 | 0,64 | 0,64 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,67 | 0,67 | 0,67 | 0,67 | 0,67 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,93 | 0,93 | 0,93 | 0,93 | 0,93 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,43 | 1,43 | 1,43 | 1,43 | 1,43 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,81 | 1,81 | 1,81 | 1,81 | 1,81 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| SHEAR LOAD |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCFC 4,8 without or with washer ≥ Ø14) |
Thickness of steel substructure tII = 0,40mmVRk[kN] | 0,71 | 0,71 | 0,71 | 0,71 | 0,71 |
Thickness of steel substructure tII = 0,50mmVRk[kN] | 0,71 | 0,81 | 0,81 | 0,81 | 0,81 |
Thickness of steel substructure tII = 0,63mmVRk[kN] | 0,71 | 0,81 | 1,26 | 1,26 | 1,26 |
Thickness of steel substructure tII = 0,75mmVRk[kN] | 0,71 | 0,81 | 1,26 | 1,51 | 1,51 |
Thickness of steel substructure tII = 1,00mmVRk[kN] | 0,71 | 0,81 | 1,26 | 1,51 | 1,72 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| 1) min (NRk,I,k ; NRk,II,k) | | | | | |