1. Mainpage
  2. R-TFIX-8M Universal Hammer-In Façade Fixing with Plastic Overmoulded Nail 8 x 115mm - cardboard box - 200 pcs.

R-TFIX-8M Universal Hammer-In Façade Fixing with Plastic Overmoulded Nail 8 x 115mm - cardboard box - 200 pcs.

Universal
New

R-TFIX-8M-115

5906675269429

Versatile hammer-in facade fixing with steel nail recommended for ETICS.

Define product parameters:

Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    200.00 pcs.5.15 kg

  • Bulk pack

    200.00 pcs.5.51 kg

  • Pallet

    8000.00 pcs.220.60 kg

Related products

Insulation retaining plate R-KWL 140 mm, polyamide - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

Rawlplug SDS Plus Rebar Drill Bit 8.0 x 150 x 210mm, PGM Approved - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

Rawlplug SDS Plus Rebar Drill Bit 8.0 x 200 x 260mm, PGM Approved - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, white - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

KWL - 90mm Insulation Retaining PP Plate - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

R-TFIX CAP For Mineral Wool, 63/10 Brown - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Insulation retaining plate R-KWL 90 mm, polyamide - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

Brickdrill SDS PLUS non-impact drill bits 8.0x260 m - plastic hanger - 1 pc.

Drill bits for non-impact drilling in ceramic materials

Dead blow hammer 0,6 kg - label - 1 pc.

Hammer with a special system that absorbs the impact energy

R-TFIX CAP For EPS, 63/10mm grey - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Counterbore cutter for EPS and mineral wool 63x10 mm - cardboard box - 1 pc.

Cutter accessory for counterbored installation of TFIX hammer-in facade insulation fixings

Counterbore plastic cutter for EPS and mineral wool 63x10 mm - cardboard box - 1 pc.

Cutter accessory for counterbored installation of TFIX hammer-in facade insulation fixings

Features

Versatile hammer-in facade fixing with steel nail recommended for ETICS.

  • Quick and easy installation in all substrates (categories A, B, C, D, E).
  • Unique sleeve compression zone for precision installations.
  • Reduced point thermal transmittance to 0.001 W/K for sizes 135-295 mm and to 0.002 W/K for sizes 95-115 mm.
  • Pre-assembled components of the fixing allow you to save time.
  • Highest loads with anchoring zone reduced in length to 25 mm.
  • Excellent plate stiffness (value 1.0 kN/mm) ensures smooth elevation surface and stable insulation system.
  • Increased head diameter enabling centric hammer driving for improvedinstallation comfort.

Product video

R-TFIX-8M: countersunk installation in EPS (R-KFS-63/10)

R-TFIX-8M: montaż powierzchniowy w wełnie mineralnej

R-TFIX-8M: montaż powierzchniowy w styropianie EPS

R-TFIX-8M: countersunk installation in EPS (R-KFS-63)

Montaż wbijanego kołka fasadowego R-TFIX-8M – instruktaż Rawlplug

R-TFIX-8M hammer-in facade fixing installation – Rawlplug tutorial

Rawlplug Academy: jaki łącznik fasadowy wybrać

Krok po kroku: jak montować kołki fasadowe z trzpieniem wbijanym

Substrates

Concrete C12/15-C50/60 (A)

Concrete C12/15-C50/60 (A)

External wall panel of concrete C16/20 – C50/60 (A)

External wall panel of concrete C16/20 – C50/60 (A)

Solid brick (B)

Solid brick (B)

Solid sand-lime brick (B)

Solid sand-lime brick (B)

Hollow brick (C)

Hollow brick (C)

Hollow sand-lime brick (C)

Hollow sand-lime brick (C)

Lightweight concrete block (C)

Lightweight concrete block (C)

Hollow lightweight concrete block (D)

Hollow lightweight concrete block (D)

Autoclaved aerated concrete (E)

Autoclaved aerated concrete (E)

Vertically-perforated clay block (C)

Vertically-perforated clay block (C)

Approved surfaces

Applications

Facades - thermal insulation systems

Full list of variations

Length
Type of package
Pieces. per pack.
Index
EAN
Catalog price for pack. net

Substitutes

Expert advice

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Clean drilled hole 3 times.

3

Insert the fixing into the drilled hole.

4

Drive the pin into the expansion sleeve until the pin, the pin plate and thermal insulation are aligned on one surface.

5

Correctly fastened R-TFIX-8M pin.

Installation data

Approvals and publications

Technical library

(7)

Technical assessments(3)

ETA-17/0592

UKTA_R_TFIX_8M_0836_22_6290i1

KOT-2021/1550

Declarations(2)

DoP_new_R_TFIX_8M

UKTA-DoP-22/6290-R-TFIX-8M

Certificates(2)

1488_CPR_0545_Z_new

020_UWB-1064/Z

Catalogues and product cards

(1)

Product cards(1)

Product card

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2025 Koelner Rawlplug IP