1. Mainpage
  2. Universal hammer-in facade fixing R-TFIX-8M 8x235 mm with metal nail - cardboard box - 100 pcs.

Universal hammer-in facade fixing R-TFIX-8M 8x235 mm with metal nail - cardboard box - 100 pcs.

Universal
Bestseller

R-TFIX-8M-235

5906675269481

Versatile hammer-in facade fixing with steel nail recommended for ETICS.

Define product parameters:

Length
Packaging and quantity

Related products

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, white - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Rebardrill SDS Plus drill bits 8x250x310 mm - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

Insulation retaining plate R-KWL 140 mm, polyamide - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

R-TFIX-CAP Mineral wool cap 63x10 mm - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Insulation retaining plate R-KWL 90 mm, polyamide - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, grey - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Aggressor SDS Plus drill bits 8x250x310 mm - plastic hanger - 1 pc.

Drill bits SDS plus for fast drilling in concrete

Counterbore plastic cutter for EPS and mineral wool 63x10 mm - cardboard box - 1 pc.

Cutter accessory for counterbored installation of TFIX hammer-in facade insulation fixings

18 V RawlHAMMER 2.0J 20mm Cordless rotary hammer drill, Set with RawlCASE, 2 batteries 5.0Ah and 6.5 A RawlCHARGER - plastic case - 1 pc.

18V SDS plus Cordless hammer drill "RawlHammer"

Brickdrill SDS PLUS non-impact drill bits 8.0x310 m - plastic hanger - 1 pc.

Drill bits for non-impact drilling in ceramic materials

Dead blow hammer 0,6 kg - label - 1 pc.

Hammer with a special system that absorbs the impact energy

Counterbore cutter for EPS and mineral wool 63x10 mm - cardboard box - 1 pc.

Cutter accessory for counterbored installation of TFIX hammer-in facade insulation fixings

Features

Versatile hammer-in facade fixing with steel nail recommended for ETICS.

  • Quick and easy installation in all substrates (categories A, B, C, D, E).
  • Unique sleeve compression zone for precision installations.
  • Reduced point thermal transmittance to 0.001 W/K for sizes 135-295 mm and to 0.002 W/K for sizes 95-115 mm.
  • Pre-assembled components of the fixing allow you to save time.
  • Highest loads with anchoring zone reduced in length to 25 mm.
  • Excellent plate stiffness (value 1.0 kN/mm) ensures smooth elevation surface and stable insulation system.
  • Increased head diameter enabling centric hammer driving for improvedinstallation comfort.

Product video

R-TFIX-8M: countersunk installation in EPS (R-KFS-63/10)

R-TFIX-8M: montaż powierzchniowy w wełnie mineralnej

R-TFIX-8M: montaż powierzchniowy w styropianie

R-TFIX-8M: countersunk installation in EPS (R-KFS-63)

Montaż wbijanego kołka fasadowego R-TFIX-8M – instruktaż Rawlplug

R-TFIX-8M hammer-in facade fixing installation – Rawlplug tutorial

Substrates

Concrete C12/15-C50/60 (Use category A)

Concrete C12/15-C50/60 (Use category A)

External wall panel of concrete C16/20 – C50/60 (Use category A)

External wall panel of concrete C16/20 – C50/60 (Use category A)

Solid brick (Use category B)

Solid brick (Use category B)

Solid sand-lime brick (Use category B)

Solid sand-lime brick (Use category B)

Hollow brick (Use category C)

Hollow brick (Use category C)

Vertically-perforated clay block (Use category C)

Vertically-perforated clay block (Use category C)

Hollow sand-lime brick (Use category C)

Hollow sand-lime brick (Use category C)

Hollow lightweight concrete block (Use category D)

Hollow lightweight concrete block (Use category D)

Autoclaved aerated concrete (Use Category E)

Autoclaved aerated concrete (Use Category E)

Lightweight concrete block (Use category C)

Lightweight concrete block (Use category C)

Approved surfaces

Applications

Facades - thermal insulation systems

Substitutes

Services

E-learning training

E-learning training

Learn more
Design Consulting

Design Consulting

EasyFix

EasyFix

Training at the Rawlplug Academy center

Training at the Rawlplug Academy center

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Clean drilled hole 3 times.

3

Insert the fixing into the drilled hole.

4

Drive the pin into the expansion sleeve until the pin, the pin plate and thermal insulation are aligned on one surface.

5

Correctly fastened R-TFIX-8M pin.

Approvals and publications

Technical library and approvals

Choose document:

ETA-17/0592

1488-CPR-0545/Z

DoP-17/0592-R-TFIX-8M

UKTA-22/6290_R-TFIX-8M

UKTA-DoP-22/6290-R-TFIX-8M

KOT-2021/1550

020_UWB-1064/Z

Product card and catalogues

Choose product card:

Product card

Choose product catalog:

Specification Design Guide

General catalogue - PDF

Leaflet R_TFIX_8M

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2024 Koelner Rawlplug IP