1. Mainpage
  2. Products
  3. Fixings
  4. Roofing fixings
  5. Roofing screws
  6. Roofing Screws for Concrete
  7. R-WBT Screws for concrete and timber T25 6.1x90 mm zinc flak coating - cardboard box - 100 pcs.

R-WBT Screws for concrete and timber T25 6.1x90 mm zinc flak coating - cardboard box - 100 pcs.

Solid walls

R-WBT-61090

5906675101309

Rawlplug

Screw for concrete substrates TX25 head. Shape and type of the thread specially design to allow connecting to concrete and wood.

Define product parameters:

Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.1.34 kg

  • Bulk pack

    1600.00 pcs.21.77 kg

  • Pallet

    38400.00 pcs.522.55 kg

Features

Screw for concrete substrates TX25 head. Shape and type of the thread specially design to allow connecting to concrete and wood.

  • Surface-hardened thread – provides high wear resistance while maintaining the flexibility of the shank.
  • High quality anti-corrosion coating guarantees resistance of 15 Kesternich cycles.
  • Shape and type of the thread specially design to allow connecting to concrete and wood.
  • The drill point is designed to provide a fast and hassle-free installation. Sharp point of the drill prevents movement of the surface of the fixture.
  • Pre-assembly with other component is possible before installation.

Substrates

Concrete

Concrete

Concrete slab

Concrete slab

Timber

Timber

Approved surfaces

Applications

Flat roofs

Full list of variations

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole of required diameter and depth.

2

Place the plastic sleeve with the R-WBT screw in the insulating material.

3

Using drilling machine, drive the R-WBT screw into substrate until fixing depth is reached.

4

Properly mounted sleeve with R-WX screw.

Design data
s1_sizeØ6.1
s4_thread_diameter_d_mm6,1
s4_hole_diameter_in_substrate_dsub0_sub_mm5
s4_min_substrate_thickness_hsubmin_sub_mm100
s4_min_hole_depth_in_substrate_hsub0_sub_mm35
s4_installation_depth_hsubnom_sub_mm30
s4_min_edge_distance_csubmin_sub_mm40
s4_min_spacing_ssubmin_sub_mm50
s4_wrench_size__mmT25
SKUscrew_diameter_d_mmscrew_length_L_mm6.150
6.175
6.190
6.1100
6.1120
6.1140
6.1160
6.1180
6.1200
6.1220
6.1240
6.1260
6.1300
s1_fixing_typeR-WBT
s21_uncracked_concrete_c20_25
s4_effective_embedment_depth_hsubef_sub_mm30
s22_tension__load
s21_characteristic_resistance__pullout_failure
s4_characteristic_load_nsubrk_sub_kn3,08
s4_partial_safety_factor_ysubm_sub_2,52
s21_steel_sheet_or_pullthrough_failure
s4_thickness_of_metal_sheeting_tsubi_sub__0_40_nsubrk_i_k_sub_mm0,47
s4_thickness_of_metal_sheeting_tsubi_sub__0_50_nsubrk_i_k_sub_mm0,82
s4_thickness_of_metal_sheeting_tsubi_sub__0_63_nsubrk_i_k_sub_mm1,11
s4_thickness_of_metal_sheeting_tsubi_sub__0_75_nsubrk_i_k_sub_mm1,26
s4_thickness_of_metal_sheeting_tsubi_sub__0_88_nsubrk_i_k_sub_mm1,31
s4_thickness_of_metal_sheeting_tsubi_sub___1_00_nsubrk_i_k_sub_mm1,41
s4_partial_safety_factor_ysubm_sub_1,33
s22_shear__load
s21_characteristic_resistance_
s4_characteristic_load_vsubrk_sub_kn2,31
s4_partial_safety_factor_ysubm_sub_1,33
s21_steel_sheet_or_pullthrough_failure
s4_thickness_of_metal_sheeting_tsubi_sub__0_40_vsubrk_sub_mm0,86
s4_thickness_of_metal_sheeting_tsubi_sub__0_50_vsubrk_sub_mm1,57
s4_thickness_of_metal_sheeting_tsubi_sub__0_63_vsubrk_sub_mm1,76
s4_thickness_of_metal_sheeting_tsubi_sub__0_75_vsubrk_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub__0_88_vsubrk_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub___1_00_vsubrk_sub_mm1)
s4_partial_safety_factor_ysubm_sub_1,33
s24_sup1_sup_pullout_failure
s1_fixing_typeR-WBT
s21_cracked_concrete_c20_25
s4_effective_embedment_depth_hsubef_sub_mm30
s22_tension__load
s21_characteristic_resistance__pullout_failure
s4_characteristic_load_nsubrk_sub_kn1,02
s4_partial_safety_factor_ysubm_sub_2,52
s21_steel_sheet_or_pullthrough_failure
s4_thickness_of_metal_sheeting_tsubi_sub__0_40_nsubrk_i_k_sub_mm0,47
s4_thickness_of_metal_sheeting_tsubi_sub__0_50_nsubrk_i_k_sub_mm0,82
s4_thickness_of_metal_sheeting_tsubi_sub__0_63_nsubrk_i_k_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub__0_75_nsubrk_i_k_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub__0_88_nsubrk_i_k_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub___1_00_nsubrk_i_k_sub_mm1)
s4_partial_safety_factor_ysubm_sub_1,33
s22_shear__load
s21_characteristic_resistance_
s4_characteristic_load_vsubrk_sub_kn1,02
s4_partial_safety_factor_ysubm_sub_1,33
s21_steel_sheet_or_pullthrough_failure
s4_thickness_of_metal_sheeting_tsubi_sub__0_40_vsubrk_sub_mm0,86
s4_thickness_of_metal_sheeting_tsubi_sub__0_50_vsubrk_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub__0_63_vsubrk_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub__0_75_vsubrk_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub__0_88_vsubrk_sub_mm1)
s4_thickness_of_metal_sheeting_tsubi_sub___1_00_vsubrk_sub_mm1)
s4_partial_safety_factor_ysubm_sub_1,33
s24_sup1_sup_pullout_failure
s1_fixing_typeR-WBT
s21_concrete_c20_25
s4_effective_embedment_depth_hsubef_sub_mm30
s22_tension__load
s21_characteristic_resistance__pullout_failure
s4_characteristic_fire_resistance_r30_fsup0_supsubrk_fi30_sub_kn0,25
s4_characteristic_fire_resistance_r60_fsup0_supsubrk_fi60_sub_kn0,25
s4_characteristic_fire_resistance_r90_fsup0_supsubrk_fi90_sub_kn0,25
s4_characteristic_fire_resistance_r120_fsup0_supsubrk_fi120_sub_kn0,20
s4_spacing__ssubcr_fi_sub_mm120
s4_edge_distance__csubcr_fi_sub_mm60

Approvals and publications

Technical library

(14)

Technical assessments(5)

ETA-23/0198

ETA-23/0198

UKTA-0836-22/6338

UKTA-22/6338

ITB_KOT_2022_2206_2022_08_22_R_GOKII_R_POK_R_POW

ITB-KOT-2022/2206

ITB-KOT-2018-0489_2025-06-12w4 - WBT - (non structural usage)

ITB-KOT-2018-0489w4

KOT-2020/1559

ITB-KOT-2020/1559

Declarations(5)

DoP-23/0198-R-GOK-II

DoP-23/0198-R-GOK-II

UKTA-DoP-22/6338-R-WBT

UKTA-DoP-22/6338-R-WBT

KDWU_R_WBT

KDWU-2022-2206-R-WBT

KDWU_ITB_KOT_2018_0489_2021_09_29w3_WBT

KDWU-2018-0489-4-WBT

KDWU_ITB_KOT_2020_1559_2020_12_10w1_WBT

KDWU-2020-1559-2-WBT

Certificates(3)

1488-CPR-0697/Z

CPR

020_UWB_2419_Z

020-UWB-2419/Z

020_UWB_1270_Z

020-UWB-1270/Z

Documents(1)

FM approval PR465265 (2026-02-23)

R-GOK-II + R-WBT / R-WO / R-WX - Fasteners for flexible roof waterproofing systems

Catalogues and product cards

(4)

Product cards(1)

R-WBT - Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP