1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Througbolts
  6. Throughbolts XPT
  7. R-XPTIIA4 Throughbolt M10 x 80mm, A4 Stainless Steel - cardboard box - 50 pcs.

R-XPTIIA4 Throughbolt M10 x 80mm, A4 Stainless Steel - cardboard box - 50 pcs.

Solid walls

R-XPTIIA4-10080/20

5906675047300

Stainless steel throughbolt for non-cracked concrete

Define product parameters:

Diameter
Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    50.00 pcs.2.74 kg

  • Bulk pack

    50.00 pcs.2.74 kg

  • Pallet

    8000.00 pcs.438.40 kg

Features

Stainless steel throughbolt for non-cracked concrete

  • Stainless steel anchor for the highest corrosion resistance.
  • Highest quality ensures maximum load capability.
  • Embedment depth markings help to ensure precise installation of the anchor.
  • Simple through-installation (drilling and installation through fixed material).
  • High performance in non-cracked concrete confirmed by ETA Option 7.
  • Suitable for reduced embedment to avoid contact with reinforcement.

Product video

rawlplug_rxpt_throughb

Substrates

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Balustrades

Handrails

Poles and road signs

Profiled and cover sheets

Steel structures

Storage racks

Ventilated facades

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Blow out the dust at least 4 times with the hand pump.

3

Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached.

4

Tighten to the recommended torque.

5

The anchor is properly fixed in the concrete base.

Installation data
Design data
SizeM6M8M10M12M16M20M24
Thread diameterd[mm]
681012162024
Hole diameter in substrated0[mm]
681012162024
Hole diameter in fixturedf[mm]
791113182226
Installation torqueTinst[Nm]
5153050100150230
Wrench sizeSw[mm]
10131719243036
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
55657990110140155
Min. installation depthhnom,s[mm]
50556980100120135
Min. substrate thicknesshmin,s[mm]
100100120140170210230
Min. edge distancecmin[mm]
5050608590160200
For spacing distancess ≥[mm]
-100125110200--
Min. spacingsmin[mm]
456590110170170180
For edge distancesc ≥[mm]
-658085120--
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
4050597090120140
Min. installation depthhnom,r[mm]
3040496080100120
Min. substrate thicknesshmin,r[mm]
100100100100130210230
Min. edge distancecmin[mm]
455080100120125160
For spacing distancess ≥[mm]
-100150190190--
Min. spacingsmin[mm]
4065115150190160190
For edge distancesc ≥[mm]
-65110120120--
SizeM6M8M10M12M16M20M24
Nominal ultimate tensile strengthfuk[N/mm2]
800600600550550500500
Nominal yield strengthfyk[N/mm2]
600480480440440210210
Cross sectional area As[mm2]
14,225,540,760,1106,6162,9234,5
Elastic section modulusWel[mm3]
13,131,262,3109276,4539,9940,9
Characteristic bending resistanceM0Rk,s[Nm]
12,6224572180323,9564,5
Design bending resistanceM[Nm]
9,417,63657,6144136,1237,2
SizeM6M8M10M12M16M20M24
Standard embedment depthhnom[mm]
50556980100120135
Reduced embedment depthhnom[mm]
3040496080100120
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD VRu,m
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD VRk
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
DESIGN RESISTANCE
TENSION LOAD NRd
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD VRd
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
RECOMMENDED LOAD
TENSION LOAD Nrec
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD Vrec
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SizeM6M8M10M12M16M20M24
Effective embedment depthhef[mm]
224232473959486865858510597112
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
11,8311,8321,221,233,633,644,844,882,682,6114,03114,03164,16164,16
Partial safety factorγMS[-]
1,61,61,51,51,51,51,51,51,51,52,862,862,862,86
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
1,57,57,591216-25--12201625
Installation safety factorγinst[-]
1,681,681,21,21,2111111,681,681,681,68
Increasing factors for concrete C30/37Ψc[-]
1,221,221,171,221,221,221,221,221,221,221,221,221,221,22
Increasing factors for concrete C40/50Ψc[-]
1,411,411,321,411,411,411,411,411,411,411,411,411,411,41
Increasing factors for concrete C50/60Ψc[-]
1,551,551,421,551,551,551,551,551,551,551,551,551,551,55
CONCRETE CONE FAILURE
Factor for uncracked concretekucr,N[-]
1111111111111111111111111111
Installation safety factorγinst[-]
1,681,681,21,21,2111111,681,681,681,68
Spacingscr,N[mm]
6612696141117177144204195255255315291336
Edge distanceccr,N[mm]
3363487159897210298128128168146168
CONCRETE SPLITTING FAILURE
Spacingscr,N[mm]
100210160240200300250340320430430560500580
Edge distanceccr,N[mm]
5510580120100150125170160215215280250290
Installation safety factorγinst[-]
1,681,681,21,21,2111111,681,681,681,68
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armV0Rk,s[kN]
8,048,0411,711,718,518,524,624,645,445,461,2561,2588,2588,25
Ductility factork7[-]
0,80,80,80,80,80,80,80,80,80,80,80,80,80,8
Characteristic resistance with lever armMRk,s[Nm]
12,6212,62222245457272180180323,9323,9564,5564,5
Partial safety factorγMS[-]
1,331,331,251,251,251,251,251,251,251,252,382,382,382,38
CONCRETE PRY-OUT FAILURE
Factork[-]
11111112221111
Installation safety factorγinst[-]
1,21,21,21,21,21,21,21,21,21,22222
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
224232473959486865858510597112
Anchor diameterdnom[mm]
668810101212161620202424
Installation safety factorγinst[-]
111,21,21,2111111111

Approvals and publications

Technical library

(6)

Technical assessments(2)

ETA-17/0782 (2017-09-21)

R-XPTII-A4 - Torque controlled expansion anchor for use in uncracked concrete.

UKTA-22/6204 (2022-11-11)

R-XPTII-A4 - Torque controlled expansion anchor for use in uncracked concrete.

Declarations(2)

DoP-17/0782 R-XPTII-A4 - ETA-17/0782 (2017-09-21)

R-XPTII-A4 - Torque controlled expansion anchor for use in uncracked concrete.

UKTA-DoP-22/6204-R-XPTII-A4 - UKTA-22/6204 (2022-11-11)

R-XPTII-A4 - Torque controlled expansion anchor for use in uncracked concrete.

Certificates(2)

1488-CPR-0633/W - ETA-17/0782 (2017-09-21)

R-XPTII-A4 - Torque controlled expansion anchor for use in uncracked concrete.

UK 0836-CPR-23/P6735 - UKTA-22/6204 (2022-11-11)

R-XPTII-A4 - Torque controlled expansion anchor for use in uncracked concrete.

Catalogues and product cards

(4)

Product cards(1)

Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP