1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Concrete Screwbolts
  6. R-HLX High Performance Concrete Screwbolts
  7. R-HLX Concrete Screw Anchor M14 / 17.4 x 75mm, Hex Flange, Zinc Flake, ETA-23/0707 - cardboard box - 20 pcs.

R-HLX Concrete Screw Anchor M14 / 17.4 x 75mm, Hex Flange, Zinc Flake, ETA-23/0707 - cardboard box - 20 pcs.

Solid walls
New

R-HLX-14X075-HF-ZF

5906675533940

Induction hardened concrete screw anchor with hex head

Define product parameters:

Diameter
Length
Coating
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    20.00 pcs.2.77 kg

  • Bulk pack

    20.00 pcs.2.77 kg

  • Pallet

    5120.00 pcs.709.12 kg

Features

Induction hardened concrete screw anchor with hex head

  • The new thread geometry with additional cutting teeth ensures quick and easy installation, also in reinforced concrete C20/25 - C50/60.
  • Fire resistance R30-R120.
  • R-HLX concrete screws can be used in earthquake-prone zones - seismic category C1 and C2.
  • Special anti-corrosion zinc flake coating for increased corrosion resistance.
  • Possibility of installation near the edge of concrete and at short distances from adjacent screws.
  • Polish production guarantees the highest precision of workmanship and its repeatability.
  • Possibility of disassembly and repeated use after verifying thread wear with a tester.
  • The highest parameters in cracked and uncracked concrete C20/25 - C50/60 confirmed in the ETA.
  • Induction hardening ensures high surface hardness and high core impact strength.

Product video

R-HLX High performed screwbolt

Rawlplug Academy: czym jest i jak działa kotwa mechaniczna?

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Roads and bridges

Sanitary and gas installations

Scaffolding

Seats in public facilities

Steel structures

Storage racks

Balustrades

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole with a hammer drill (1a) ) to the required depth according to the table

2

Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..

3

Screw the concrete screw into the hole with an impact wrench and a suitable impact socket. Tighten until the fixture is clamped to the substrate. Installation with any tangential impact wrench. Finish screwing when the screw head touches the fastened element/substrate. The screw head must not be damaged

4

Possibility to unscrew the fixed anchor to a maximum height of 10mm. In the adjustment process, the permissible thickness of the fastened elements (Tfix) must be observed

5

Finish screwing when the anchor touches the fastened element. The adjustment operation can be performed twice

Installation data
Design data
s1_size68101214
s4_thread_diameter_d_mm7,910,412,714,916,9
s4_hole_diameter_in_substrate_dsub0_sub_mm68101214
s4_hole_diameter_in_fixture_dsubf_sub_mm912141618
s4_wrench_size_sw_mm1013151721
s4_external_diameter_of_washer_d_mm14,218,52126,631,7
s4_max_torque_for_impact_screw_driver_tsubimp_max_sub_nm25035065010001000
s21_standard_embedment_depth
s4_min_hole_depth_in_substrate_hsub0_s_sub_mm658595110125
s4_real_hole_depth_in_substrate_hsub0_sub_mmL+10-tfixL+10-tfixL+10-tfixL+10-tfixL+10-tfix
s4_min_installation_depth_hsubnom_s_sub_mm557085100115
s4_min_substrate_thickness_hsubmin_s_sub_mm80110130155190
s4_min_edge_distance_csubmin_sub_mm35356080100
s4_min_spacing_ssubmin_sub_mm35356080100
s21_reduced_embedment_depth
s4_min_hole_depth_in_substrate_hsub0_r_sub_mm5070859095
s4_real_hole_depth_in_substrate_hsub0_sub_mmL+10-tfixL+10-tfixL+10-tfixL+10-tfixL+10-tfix
s4_min_installation_depth_hsubnom_r_sub_mm4060758085
s4_min_substrate_thickness_hsubmin_r_sub_mm80110120130130
s4_min_edge_distance_csubmin_sub_mm35356080100
s4_min_spacing_ssubmin_sub_mm35356080100
s21_minimum_embedment_depth
s4_min_hole_depth_in_substrate_hsub0_r_sub_mm4560657075
s4_real_hole_depth_in_substrate_hsub0_sub_mmL+10-tfixL+10-tfixL+10-tfixL+10-tfixL+10-tfix
s4_min_installation_depth_hsubnom_r_sub_mm3550556065
s4_min_substrate_thickness_hsubmin_r_sub_mm80110100110110
s4_min_edge_distance_csubmin_sub_mm35356080100
s4_min_spacing_ssubmin_sub_mm35356080100
s1_size68101214
s4_standard_embedment_depth_hsubnom_sub_mm557085100115
s4_reduced_embedment_depth_hsubnom_sub_mm4060758085
s4_minimum_embedment_depth_hsubnom_sub_mm3550556065
s22_mean_ultimate_resistance
s23_tension_load_nsubru_m_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn18,9926,3437,8548,359,56
s4_reduced_embedment_depth__kn11,0919,0330,5933,7536,19
s4_minimum_embedment_depth__kn8,3216,4418,3721,0623,15
s21_cracked_concrete
s4_standard_embedment_depth__kn10,8812,2426,6433,9941,92
s4_reduced_embedment_depth__kn7,1111,5921,5323,7525,47
s4_minimum_embedment_depth__kn4,029,8612,9314,8216,29
s23_shear_load_vsubru_m_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn10,6719,4729,9245,7661,16
s4_reduced_embedment_depth__kn10,6719,4729,9245,7661,16
s4_minimum_embedment_depth__kn8,9516,4418,3742,1246,31
s21_cracked_concrete
s4_standard_embedment_depth__kn10,6719,4729,9245,7661,16
s4_reduced_embedment_depth__kn7,8119,4729,9245,7650,94
s4_minimum_embedment_depth__kn6,311,5712,9329,6432,59
s22_characteristic_resistance
s23_tension_load_nsubrk_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn13,820,627,5835,243,4
s4_reduced_embedment_depth__kn813,8722,2924,626,38
s4_minimum_embedment_depth__kn4,511,913,3915,3516,87
s21_cracked_concrete
s4_standard_embedment_depth__kn3,51119,324,630,39
s4_reduced_embedment_depth__kn2915,617,218,46
s4_minimum_embedment_depth__kn289,3710,711,8
s23_shear_load_vsubrk_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn9,717,727,241,655,6
s4_reduced_embedment_depth__kn8,0817,727,241,652,75
s4_minimum_embedment_depth__kn6,5211,9813,3930,733,75
s21_cracked_concrete
s4_standard_embedment_depth__kn9,717,727,241,655,6
s4_reduced_embedment_depth__kn5,6617,727,234,4436,93
s4_minimum_embedment_depth__kn4,578,399,3721,4923,62
s22_design_resistance
s23_tension_load_nsubrd_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn9,213,7318,3923,4728,93
s4_reduced_embedment_depth__kn5,339,2514,8616,417,58
s4_minimum_embedment_depth__kn37,938,9310,2311,25
s21_cracked_concrete
s4_standard_embedment_depth__kn2,337,3312,8716,420,26
s4_reduced_embedment_depth__kn1,33610,411,4712,31
s4_minimum_embedment_depth__kn1,335,336,257,137,87
s23_shear_load_vsubrd_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn7,7614,1621,7633,2844,48
s4_reduced_embedment_depth__kn5,3914,1621,7632,835,17
s4_minimum_embedment_depth__kn4,357,998,9320,4622,5
s21_cracked_concrete
s4_standard_embedment_depth__kn6,4714,1621,7632,8540,52
s4_reduced_embedment_depth__kn3,7712,9520,8122,9624,62
s4_minimum_embedment_depth__kn3,045,596,2514,3215,75
s22_recommended_load
s23_tension_load_nsubrec_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn6,579,8113,1416,7620,67
s4_reduced_embedment_depth__kn3,816,6110,6211,7112,56
s4_minimum_embedment_depth__kn2,145,676,387,318,03
s21_cracked_concrete
s4_standard_embedment_depth__kn1,675,249,1911,7114,47
s4_reduced_embedment_depth__kn0,954,297,438,198,79
s4_minimum_embedment_depth__kn0,953,814,465,15,62
s23_shear_load_vsubrec_sub
s21_uncracked_concrete
s4_standard_embedment_depth__kn5,5410,1115,5423,7731,77
s4_reduced_embedment_depth__kn3,8510,1115,5423,4325,12
s4_minimum_embedment_depth__kn3,115,716,3814,6216,07
s21_cracked_concrete
s4_standard_embedment_depth__kn4,6210,1115,5423,4728,94
s4_reduced_embedment_depth__kn2,699,2514,8616,417,58
s4_minimum_embedment_depth__kn2,173,994,4610,2311,25
s1_size68101214
s4_nominal_embedment_depth_hsubnom_sub_mm35405550607055758560801006585115
s4_effective_embedment_depth_hsubef_sub_mm263043394356425968466380496692
s23_tension_load
s21_steel_failure
s4_characteristic_resistance_nsubrk_s_sub_kn19,419,419,435,435,435,454,354,354,383,183,183,1111,1111,1111,1
s4_partial_safety_factor_ysubms_sub_1,51,51,51,51,51,51,51,51,51,51,51,51,51,51,5
s21_pullout_failure
s4_characteristic_resistance_in_uncracked_concrete_c20_25_nsubrk_p_ucr_sub_kn4,5813,811,916,320,613,422,327,615,424,635,216,926,443,4
s4_characteristic_resistance_in_cracked_concrete_c20_25_nsubrk_p_cr_sub_kn223,589119,415,619,310,717,224,611,818,530,4
s4_installation_safety_factor_ysubinst_sub_1,01)1,01)1111111111111
s4_increasing_factors_for_concrete_c30_37_psisubc_sub_1,171,171,171,171,171,171,221,221,221,221,221,221,221,221,22
s4_increasing_factors_for_concrete_c40_50_psisubc_sub_1,321,321,321,321,321,321,411,411,411,411,411,411,411,411,41
s4_increasing_factors_for_concrete_c50_60_psisubc_sub_1,421,421,421,421,421,421,551,551,551,551,551,551,551,551,55
s21_concrete_cone_failure
s4_installation_safety_factor_ysubinst_sub_1,01)1,01)1111111111111
s4_factor_for_cracked_concrete_ksubcr_n_sub_7,77,77,77,77,77,77,77,77,77,77,77,77,77,77,7
s4_factor_for_uncracked_concrete_ksubucr_n_sub_111111111111111111111111111111
s4_spacing_ssubcr_n_sub_mm7890129117129168126177204138189240147198276
s4_edge_distance_csubcr_n_sub_mm394564,558,564,5846388,51026994,512073,599138
s21_concrete_splitting_failure
s4_installation_safety_factor_ysubinst_sub_1,01)1,01)1111111111111
s4_spacing_ssubcr_sp_sub_mm8090130120150170120180200140200240150200280
s4_edge_distance_csubcr_sp_sub_mm40456560758560901007010012075100140
s23_shear_load
s21_steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_sub_kn9,79,79,717,717,717,727,227,227,241,641,641,655,655,655,6
s4_ductility_factor_ksub7_sub_111111111111111
s4_characteristic_resistance_with_lever_arm_msubrk_s_sub_nm16,116,116,139,839,839,875,875,875,8143,4143,4143,4221,7221,7221,7
s4_partial_safety_factor_ysubms_sub_1,251,251,251,251,251,251,251,251,251,251,251,251,251,251,25
s21_concrete_pryout_failure
s4_factor_k_111122122222222
s4_installation_safety_factor_ysubinst_sub_111111111111111
s21_concrete_edge_failure
s4_effective_length_of_anchor_lsubf_sub_mm35405550607055758560801006585115
s4_anchor_diameter_dsubnom_sub_mm666888101010121212141414
s4_installation_safety_factor_ysubinst_sub_111111111111111
s24_sup1_sup_holes_without_cleaning_ysubinst_sub__1_2
s1_size68101214
s23_r_for_ei__30_min
s4_nominal_embedment_depth_hsubnom_sub_mm35405550607055758560801006585115
s23_tension_load
s21_steel_failure
s4_characteristic_resistance_nsubrk_s_sub_kn1,81,81,83,83,83,86,66,66,611,411,411,415,215,215,2
s21_pullout_failure
s4_characteristic_resistance_nsubrk_p_sub_kn0,50,50,822,22,72,33,94,82,64,36,12,94,67,6
s23_shear_load
s21_steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_sub_kn1,81,81,83,83,83,86,66,66,611,411,411,415,215,215,2
s4_characteristic_resistance_with_lever_arm_msubrk_s_sub_nm1,51,51,54,34,34,39,39,39,319,719,719,730,430,430,4
s23_r_for_ei__60_min
s4_nominal_embedment_depth_hsubnom_sub_mm35405550607055758560801006585115
s23_tension_load
s21_steel_failure
s4_characteristic_resistance_nsubrk_s_sub_kn1,41,41,42,92,92,95558,58,58,511,411,411,4
s21_pullout_failure
s4_characteristic_resistance_nsubrk_p_sub_kn0,50,50,822,22,72,33,94,82,64,36,12,94,67,6
s23_shear_load
s21_steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_sub_kn1,41,41,42,92,92,95558,58,58,511,411,411,4
s4_characteristic_resistance_with_lever_arm_msubrk_s_sub_nm1,21,21,23,33,33,377714,814,814,822,922,922,9
s23_r_for_ei__90_min
s4_nominal_embedment_depth_hsubnom_sub_mm35405550607055758560801006585115
s23_tension_load
s21_steel_failure
s4_characteristic_resistance_nsubrk_s_sub_kn1112223,43,43,45,75,75,77,67,67,6
s21_pullout_failure
s4_characteristic_resistance_nsubrk_p_sub_kn0,50,50,822,22,72,33,94,82,64,36,12,94,67,6
s23_shear_load
s21_steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_sub_kn1112223,43,43,45,75,75,77,67,67,6
s4_characteristic_resistance_with_lever_arm_msubrk_s_sub_nm0,80,80,82,32,32,34,84,84,89,99,99,915,315,315,3
s23_r_for_ei__120_min
s4_nominal_embedment_depth_hsubnom_sub_mm35405550607055758560801006585115
s23_tension_load
s21_steel_failure
s4_characteristic_resistance_nsubrk_s_sub_kn0,80,80,81,61,61,62,62,62,64,34,34,35,75,75,7
s21_pullout_failure
s4_characteristic_resistance_nsubrk_p_sub_kn0,40,40,71,61,82,21,83,13,82,13,44,92,33,66
s23_shear_load
s21_steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_sub_kn0,80,80,81,61,61,62,62,62,64,34,34,35,75,75,7
s4_characteristic_resistance_with_lever_arm_msubrk_s_sub_nm0,70,70,71,81,81,83,73,73,77,47,47,411,511,511,5
s1_size68101214
s4_nominal_embedment_depth_hsubnom_sub_mm405550607055758560801006585115
s22_seismic_category_c1
s21_tension_load__steel_failure
s4_characteristic_resistance_nsubrk_s_c1_sub_kn19,419,435,435,435,454,354,354,383,183,183,1111,1111,1111,1
s21_tension_load__pullout_failure
s4_characteristic_resistance_seismic_c1_nsubrk_p_c1_sub_kn23,57,68,610,58,614,417,87,612,217,58,413,121,6
s21_shear_load__steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_c1_sub_kn4,74,710,610,610,618,718,718,728,728,728,738,338,338,3
s22_seismic_category_c2
s21_tension_load__steel_failure
s4_characteristic_resistance_nsubrk_s_c2_sub_kn----35,4--54,3--83,1--111,1
s21_tension_load__pullout_failure
s4_characteristic_resistance_seismic_c2_nsubrk_p_c2_sub_kn----2--8,5--13,3--19,3
s21_shear_load__steel_failure
s4_characteristic_resistance_without_lever_arm_vsubrk_s_c2_sub_kn----3,6--8--22,3--21,6

Approvals and publications

Technical library

(14)

Technical assessments(4)

ETA-23/0707 (2025-01-24) - Cracked and uncracked concrete

R-HLX - Concrete screw for use in cracked and uncracked concrete

ETA-24/1104 (2025-06-03) - Non-structural systems

Concrete screw for use in concrete for redundant non-structural systems

KOT-2020/1559

ITB-KOT-2020/1559

ETA26_0257_PL

ETA 26-0257 (2026-06-28)

Declarations(4)

DoP-23/0707 R-HLX (ETA-23/0707)

DoP-23/0707 R-HLX (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

DoP-24/1104-R-HLX (ETA-24/1104 - Non-structural systems)

R-HLX - Cpncrete screw for use in concrete for redundant non-structural systems.

KDWU_ITB_KOT_2020_1559_2020_12_10w1_WBT

KDWU-2020-1559-2-WBT

DoP-26/0257-R-HLX (ETA 26/0257)

DoP-26/0257-R-HLX

Certificates(5)

1488-CPR-1100/W (ETA-23/0707)

CPR (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)

CPR - ETA-24/1104 (2025-06-03) - Non-structural systems

EPD-R-HLX (2025-11-27)

Type III Environmental Declaration Certificate

020_UWB_1270_Z

020-UWB-1270/Z

1488_CPR_1261_W_PL

1488-CPR-1261/W

Documents(1)

VDS CEA 4001 (2025-03-05)

Pipe hanger components for automatic sprinkler systems

Catalogues and product cards

(7)

Product cards(3)

Product card

Product card R-HLX hollow-core slab

Product card R-HLX concrete-to-concrete connections

Catalogues(4)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

KATALOG_DROGI_I_MOSTY_PL

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP