1. Mainpage
  2. Universal hammer-in facade fixing R-TFIX-8M 8x175 mm with metal nail - paper box - 200 pcs.

Universal hammer-in facade fixing R-TFIX-8M 8x175 mm with metal nail - paper box - 200 pcs.

Universal

R-TFIX-8M-175

5906675269450

Versatile hammer-in facade fixing with steel nail recommended for ETICS.

Define product parameters:

Length
Packaging and quantity

Catalog price for bx:

PLN513.80

net | VAT 23

Contact with us and check out our terms of cooperation

Related products

Rebardrill SDS Plus drill bits 8x150x210 mm - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

Rebardrill SDS Plus drill bits 8x200x260 mm - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

Insulation retaining plate R-KWL 140 mm, polyamide - paper box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

KWL Insulation retaining plate 110 mm, PP - paper box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

Dead blow hammer 0,6 kg - label - 1 pc.

Hammer with a special system that absorbs the impact energy

Brickdrill SDS PLUS non-impact drill bits 8.0x260 m - plastic hanger - 1 pc.

Drill bits for non-impact drilling in ceramic materials

KWL Insulation retaining plate 90 mm, PP - paper box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, white - paper box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Counterbore plastic cutter for EPS and mineral wool 63x10 mm - paper box - 1 pc.

Cutter accessory for counterbored installation of TFIX hammer-in facade insulation fixings

R-TFIX-CAP Mineral wool cap 63x10 mm - paper box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, grey - paper box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Insulation retaining plate R-KWL 90 mm, polyamide - paper box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

Features

Versatile hammer-in facade fixing with steel nail recommended for ETICS.

  • Quick and easy installation in all substrates (categories A, B, C, D, E).
  • Unique sleeve compression zone for precision installations.
  • Reduced point thermal transmittance to 0.001 W/K for sizes 135-295 mm and to 0.002 W/K for sizes 95-115 mm.
  • Pre-assembled components of the fixing allow you to save time.
  • Highest loads with anchoring zone reduced in length to 25 mm.
  • Excellent plate stiffness (value 1.0 kN/mm) ensures smooth elevation surface and stable insulation system.
  • Increased head diameter enabling centric hammer driving for improvedinstallation comfort.

Product video

R-TFIX-8M: countersunk installation in EPS (R-KFS-63/10)

R-TFIX-8M: montaż powierzchniowy w wełnie mineralnej

R-TFIX-8M: montaż powierzchniowy w styropianie

R-TFIX-8M: countersunk installation in EPS (R-KFS-63)

Montaż wbijanego kołka fasadowego R-TFIX-8M – instruktaż Rawlplug

R-TFIX-8M hammer-in facade fixing installation – Rawlplug tutorial

Substrates

Concrete C12/15-C50/60 (Use category A)

Concrete C12/15-C50/60 (Use category A)

External wall panel of concrete C16/20 – C50/60 (Use category A)

External wall panel of concrete C16/20 – C50/60 (Use category A)

Solid brick (Use category B)

Solid brick (Use category B)

Solid sand-lime brick (Use category B)

Solid sand-lime brick (Use category B)

Hollow brick (Use category C)

Hollow brick (Use category C)

Vertically-perforated clay block (Use category C)

Vertically-perforated clay block (Use category C)

Hollow sand-lime brick (Use category C)

Hollow sand-lime brick (Use category C)

Hollow lightweight concrete block (Use category D)

Hollow lightweight concrete block (Use category D)

Autoclaved aerated concrete (Use Category E)

Autoclaved aerated concrete (Use Category E)

Lightweight concrete block (Use category C)

Lightweight concrete block (Use category C)

Approved surfaces

Applications

Facades - thermal insulation systems

Substitutes

Services

E-learning training

E-learning training

Design Consulting

Design Consulting

EasyFix

EasyFix

Training at the Rawlplug Academy center

Training at the Rawlplug Academy center

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Clean drilled hole 3 times.

3

Insert the fixing into the drilled hole.

4

Drive the pin into the expansion sleeve until the pin, the pin plate and thermal insulation are aligned on one surface.

5

Correctly fastened R-TFIX-8M pin.

Approvals and publications

Technical library and approvals

Choose document:

ETA-17/0592

1488-CPR-0545/Z

DoP-17/0592-R-TFIX-8M

UKTA-22/6290_R-TFIX-8M

UKTA-DoP-22/6290-R-TFIX-8M

KOT-2021/1550

020_UWB-1064/Z

Product card and catalogues

Choose product card:

Product card

Choose product catalog:

Specification Design Guide

Product Catalogue

Leaflet R_TFIX_8M

© 2024 Koelner Rawlplug IP