1. Mainpage
  2. KI-10N Long expansion zone Hammer-in facade fixing with metal pin 10x180 mm - cardboard box - 250 pcs.

Universal

KI-180N

5906675218342

Koelner

Hammer-in facade fixing long expansion zone 60 mm for high performance in masonry, as well as lightweight and aerated concrete

Define product parameters:

Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    250.00 pcs.10.42 kg

  • Bulk pack

    250.00 pcs.10.42 kg

  • Pallet

    6000.00 pcs.250.18 kg

Related products

Features

Hammer-in facade fixing long expansion zone 60 mm for high performance in masonry, as well as lightweight and aerated concrete

  • Can be used with additional KWL insulation holding plate, available in 90, 110 and 140 mm flange sizes (recommended for soft insulation materials such as mineral wool).
  • Plate stiffness (value 0.5 kN/mm) ensures smooth elevation surface and stable insulation system.
  • Reduction of thermal bridge formation (value 0,003 W/K), through the integration of an impact-resistant plastic overmoulding on the nail head.
  • Steel nail allows fast and trouble-free installation with correct expansion of the plug.
  • Approved for use in base material categories B, C, D, and E.
  • Easy installation with best performance in lightweight base materials.

Solid brick (B)

Solid brick (B)

Hollow brick (C)

Hollow brick (C)

Vertically-perforated clay block (C)

Vertically-perforated clay block (C)

Lightweight concrete block (C)

Lightweight concrete block (C)

Lightweight concrete

Lightweight concrete

Aerated concrete block (D)

Aerated concrete block (D)

Autoclaved aerated concrete (E)

Autoclaved aerated concrete (E)

Approved surfaces

Facades - thermal insulation systems

Length
Packaging and quantity
Index
EAN
Catalog price for pack. net

Installation manual

Installation step by step

1

Drill a hole of required diameter and depth. Drilling depth of min 70 mm in approved materials.

2

Blow out dust at least 4 times with a hand pump.

3

Lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached.

4

Lightly tap the plastic nail into the plastic sleeve until fixing is secure and flush with insulation material. Embedment depth of min 60 mm in approved materials.

5

In soft insulation panels the fixing should be combined with insulation retaining plates KWL 90, 110, 140 mm.

Installation data

Technical library

(8)

Technical assessments(3)

ETA-07/0221 (2022-04-12)

KOT-2021/1550 (2021-03-09)

UKTA-22/6343 (2022-11-11)

Declarations(3)

DoP-07/0221 KI-10N (ETA-07/0221)

KDWU-2021-1550-KI10 N-2026-03-09

UKTA-DoP-22/6343-KI-10N (2023-10-02)

Certificates(2)

1488-CPR-0368/Z (ETA-07/0291)

020_UWB-1064/Z (KOT-2021/1550-1)

Catalogues and product cards

(2)

Product cards(1)

Product cart

Catalogues(1)

Catalogue