1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Concrete Screwbolts
  6. R-HLX High Performance Concrete Screwbolts
  7. Zinc flake pan-head induction hardened concrete screw anchor R-HLX-P-ZF 6x40 mm - cardboard box - 100 pcs.

Zinc flake pan-head induction hardened concrete screw anchor R-HLX-P-ZF 6x40 mm - cardboard box - 100 pcs.

Solid walls
New

R-HLX-06X040-P-ZF

5906675645131

Pan-Head Induction Hardened Concrete Screw Anchor

Define product parameters:

Diameter
Length
Coating
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.1.31 kg

  • Bulk pack

    100.00 pcs.1.31 kg

  • Pallet

    38400.00 pcs.503.04 kg

Features

Pan-Head Induction Hardened Concrete Screw Anchor

  • Completely removable with possibility of reuse.
  • Suitable for standard and reduced embedment depth.
  • High performance in both uncracked and cracked concrete.
  • Unique design with patented threadform ensures high performance for relatively small hole diameter.
  • Time-efficient through-fixing installation with streamlined procedure - simply drill and drive.
  • Excellent product for temporary fixing.
  • Oversize head for fixtures with elongated holes.

Product video

R-HLX High performed screwbolt

Innowacyjny_wkret_do_betonu_hartowany_indukcyjnie_RHLX_Rawlplug_KROTKI

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Hollow-core slab C30/37-C50/60

Hollow-core slab C30/37-C50/60

Approved surfaces

Applications

Balustrades

Concrete structures

Formwork

Gates

Scaffolding

Seats in public facilities

Storage racks

Temporary fixings

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole with a hammer drill (1a) ) to the required depth according to the table

2

Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..

3

Tighten to the mounted element.

4

After the anchor is installed, it must not be possible to screw it in further. The screw head must be flush with the attached element and must not be damaged.

Design data
Size6
Thread diameterd[mm]
7,97,97,9
Hole diameter in substrated0[mm]
666
Hole diameter in fixturedf[mm]
999
External diameter of washerdw[mm]
14,614,614,6
Nominal embedment depthhnom[mm]
354055
Min. hole depth in substrateh0,min[mm]
455065
Real hole depth in substrateh0[mm]
L+10-tfixL+10-tfixL+10-tfix
Min. substrate thicknesshmin[mm]
808080
Min. edge distancecmin[mm]
353535
Min. spacingsmin[mm]
353535
Wrench sizeT[mm]
T30T30T30
Max. torque for impact screw driverTimp,max[Nm]
250250250
Size6
Nominal ultimate tensile strengthfuk[N/mm2]
800
Nominal yield strengthfyk[N/mm2]
640
Cross sectional area As[mm2]
24,6
Elastic section modulusWel[mm3]
17,24
Characteristic bending resistanceM0Rk,s[Nm]
16,6
Size6
Nominal embedment depthhnom[mm]
354055
MEAN ULTIMATE RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Tension loadNRu,m[mm]
8,3211,0918,99
CRACKED CONCRETE
Tension loadNRu,m[mm]
4,027,1110,88
SHEAR LOAD
UNCRACKED CONCRETE
Shear loadVRu,m[mm]
8,9510,6710,67
CRACKED CONCRETE
Shear loadVRu,m[mm]
6,37,8110,67
CHARACTERISTIC RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Tension loadNRk[mm]
4,5813,8
CRACKED CONCRETE
Tension loadNRk[mm]
223,5
SHEAR LOAD
UNCRACKED CONCRETE
Shear loadVRk[mm]
6,528,089,7
CRACKED CONCRETE
Shear loadVRk[mm]
4,575,669,7
DESIGN RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Tension loadNRd[mm]
35,339,2
CRACKED CONCRETE
Tension loadNRd[mm]
1,331,332,33
SHEAR LOAD
UNCRACKED CONCRETE
Shear loadVRd[mm]
4,355,397,76
CRACKED CONCRETE
Shear loadVRd[mm]
3,043,776,47
RECOMMENDED LOAD
TENSION LOAD
UNCRACKED CONCRETE
Tension loadNrec[mm]
2,143,816,57
CRACKED CONCRETE
Tension loadNrec[mm]
0,950,951,67
SHEAR LOAD
UNCRACKED CONCRETE
Shear loadVrec[mm]
3,113,855,54
CRACKED CONCRETE
Shear loadVrec[mm]
2,172,694,62
Size6
Nominal embedment depthhnom[mm]
354055
Effective embedment depthhef[mm]
263043
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
19,419,419,4
Partial safety factorγMS[-]
1,51,51,5
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
4,5813,8
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN]
223,5
Increasing factors for concrete C30/37Ψc[-]
1,171,171,17
Increasing factors for concrete C40/50Ψc[-]
1,321,321,32
Increasing factors for concrete C50/60Ψc[-]
1,421,421,42
Installation safety factorγinst[-]
1,01)1,01)1
CONCRETE CONE FAILURE
Factor for cracked concretekcr,N[-]
7,77,77,7
Factor for uncracked concretekucr,N[-]
111111
Spacingscr,N[mm]
7890129
Edge distanceccr,N[mm]
394564,5
Installation safety factorγinst[-]
1,01)1,01)1
CONCRETE SPLITTING FAILURE
Spacingscr,sp[mm]
8090130
Edge distanceccr,sp[mm]
404565
Installation safety factorγinst[-]
1,01)1,01)1
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
9,79,79,7
Ductility factork7[-]
111
Characteristic resistance with lever armMRk,s[Nm]
16,116,116,1
Partial safety factorγMS[-]
1,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
111
Installation safety factorγinst[-]
111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
354055
Anchor diameterdnom[mm]
666
Installation safety factorγinst[-]
111
1) Holes without cleaning γinst = 1,2
Size6
R (for EI) = 30 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,81,81,8
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,8
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,81,81,8
Characteristic resistance with lever armMRk,s[Nm]
1,51,51,5
R (for EI) = 60 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,41,41,4
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,8
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,41,41,4
Characteristic resistance with lever armMRk,s[Nm]
1,21,21,2
R (for EI) = 90 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
111
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,8
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
111
Characteristic resistance with lever armMRk,s[Nm]
0,80,80,8
R (for EI) = 120 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,80,80,8
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,40,40,7
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,80,80,8
Characteristic resistance with lever armMRk,s[Nm]
0,70,70,7
Size6
Nominal embedment depthhnom[mm]
4055
SEISMIC CATEGORY C1
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C1[kN]
19,419,4
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistance seismic C1NRk,p,C1[kN]
23,5
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C1[kN]
4,74,7

Approvals and publications

Technical library

(8)

Technical assessments(2)

ETA-24/1104 (2025-06-03) - Non-structural systems

Concrete screw for use in concrete for redundant non-structural systems

ETA-23/0707 (2025-01-24) - Cracked and uncracked concrete

R-HLX - Concrete screw for use in cracked and uncracked concrete

Declarations(2)

DoP_23_0707_R_HLX_PL

DoP-23-0707-R-HLX

DoP-24/1104-R-HLX (ETA-24/1104 - Non-structural systems)

R-HLX - Cpncrete screw for use in concrete for redundant non-structural systems.

Certificates(3)

1488-CPR-1100/W (ETA-23/0707)

CPR (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)

CPR - ETA-24/1104 (2025-06-03) - Non-structural systems

EPD-R-HLX (2025-11-27)

Type III Environmental Declaration Certificate

Documents(1)

VDS CEA 4001 (2025-03-05)

Pipe hanger components for automatic sprinkler systems

Catalogues and product cards

(5)

Product cards(2)

Product card

Product card R-HLX hollow-core slab

Catalogues(3)

Catalogue Offer (overview) - EN

General Catalogue EN 2026/27

Specification Design Guide

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP