  7. Zinc flake coated induction hardened pan-head magnified anchor R-HLX-PX-ZF 6x40 mm - cardboard box - 100 pcs.

Zinc flake coated induction hardened pan-head magnified anchor R-HLX-PX-ZF 6x40 mm - cardboard box - 100 pcs.

Solid walls
New

R-HLX-06X040-PX-ZF

5906675645148

Self-tapping concrete screw

Define product parameters:

Diameter
Length
Coating
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.1.32 kg

  • Bulk pack

    100.00 pcs.1.32 kg

  • Pallet

    38400.00 pcs.506.88 kg

Features

Self-tapping concrete screw

  • Non-expansion functioning ensures low risk of damage to base material and makes R-LX ideal for installation near edges and adjacent anchors.
  • Completely removable with possibility of reuse.
  • Suitable for standard and reduced embedment depth.
  • High performance in both uncracked and cracked concrete.
  • Time-efficient through-fixing installation with streamlined procedure - simply drill and drive.
  • Unique design with patented threadform ensures high performance for relatively small hole diameter.
  • Excellent product for temporary fixing.
  • Oversize head for fixtures with elongated holes.
  • Different head types for any application.

Product video

R-HLX High performed screwbolt

Innowacyjny_wkret_do_betonu_hartowany_indukcyjnie_RHLX_Rawlplug_KROTKI

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Hollow-core slab C30/37-C50/60

Hollow-core slab C30/37-C50/60

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Balustrades

Concrete structures

Formwork

Gates

Scaffolding

Seats in public facilities

Storage racks

Temporary fixings

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole with a hammer drill (1a) ) to the required depth according to the table

2

Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..

3

Tighten to the mounted element.

4

After the anchor is installed, it must not be possible to screw it in further. The screw head must be flush with the attached element and must not be damaged.

Design data
Size6
Thread diameterd[mm]
7,9
Hole diameter in substrated0[mm]
6
Hole diameter in fixturedf[mm]
9
External diameter of washerdw[mm]
17
Wrench sizeT[mm]
T30
Max. torque for impact screw driverTimp,max[Nm]
250
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
65
Real hole depth in substrateh0[mm]
L+10-tfix
Min. installation depthhnom,s[mm]
55
Min. substrate thicknesshmin,s[mm]
80
Min. edge distancecmin[mm]
35
Min. spacingsmin[mm]
35
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
50
Real hole depth in substrateh0[mm]
L+10-tfix
Min. installation depthhnom,r[mm]
40
Min. substrate thicknesshmin,r[mm]
80
Min. edge distancecmin[mm]
35
Min. spacingsmin[mm]
35
MINIMUM EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
45
Real hole depth in substrateh0[mm]
L+10-tfix
Min. installation depthhnom,r[mm]
35
Min. substrate thicknesshmin,r[mm]
80
Min. edge distancecmin[mm]
35
Min. spacingsmin[mm]
35
Size6
Nominal ultimate tensile strengthfuk[N/mm2]
800
Nominal yield strengthfyk[N/mm2]
640
Cross sectional area As[mm2]
24,6
Elastic section modulusWel[mm3]
17,24
Characteristic bending resistanceM0Rk,s[Nm]
16,6
Size6
Standard embedment depthhnom[mm]
55
Reduced embedment depthhnom[mm]
40
Minimum embedment depthhnom[mm]
35
MEAN ULTIMATE RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRu,m[kN]
18,99
Reduced embedment depthNRu,m[kN]
11,09
Minimum embedment depthNRu,m[kN]
8,32
CRACKED CONCRETE
Standard embedment depthNRu,m[kN]
10,88
Reduced embedment depthNRu,m[kN]
7,11
Minimum embedment depthNRu,m[kN]
4,02
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRu,m[kN]
10,67
Reduced embedment depthVRu,m[kN]
10,67
Minimum embedment depthVRu,m[kN]
8,95
CRACKED CONCRETE
Standard embedment depthVRu,m[kN]
10,67
Reduced embedment depthVRu,m[kN]
7,81
Minimum embedment depthVRu,m[kN]
6,3
CHARACTERISTIC RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRk[kN]
13,8
Reduced embedment depthNRk[kN]
8
Minimum embedment depthNRk[kN]
4,5
CRACKED CONCRETE
Standard embedment depthNRk[kN]
3,5
Reduced embedment depthNRk[kN]
2
Minimum embedment depthNRk[kN]
2
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRk[kN]
9,7
Reduced embedment depthVRk[kN]
8,08
Minimum embedment depthVRk[kN]
6,52
CRACKED CONCRETE
Standard embedment depthVRk[kN]
9,7
Reduced embedment depthVRk[kN]
5,66
Minimum embedment depthVRk[kN]
4,57
DESIGN RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRd[kN]
9,2
Reduced embedment depthNRd[kN]
5,33
Minimum embedment depthNRd[kN]
3
CRACKED CONCRETE
Standard embedment depthNRd[kN]
2,33
Reduced embedment depthNRd[kN]
1,33
Minimum embedment depthNRd[kN]
1,33
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRd[kN]
7,76
Reduced embedment depthVRd[kN]
5,39
Minimum embedment depthVRd[kN]
4,35
CRACKED CONCRETE
Standard embedment depthVRd[kN]
6,47
Reduced embedment depthVRd[kN]
3,77
Minimum embedment depthVRd[kN]
3,04
RECOMMENDED LOAD
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNrec[kN]
6,57
Reduced embedment depthNrec[kN]
3,81
Minimum embedment depthNrec[kN]
2,14
CRACKED CONCRETE
Standard embedment depthNrec[kN]
1,67
Reduced embedment depthNrec[kN]
0,95
Minimum embedment depthNrec[kN]
0,95
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVrec[kN]
5,54
Reduced embedment depthVrec[kN]
3,85
Minimum embedment depthVrec[kN]
3,11
CRACKED CONCRETE
Standard embedment depthVrec[kN]
4,62
Reduced embedment depthVrec[kN]
2,69
Minimum embedment depthVrec[kN]
2,17
Size6
Nominal embedment depthhnom[mm]
354055
Effective embedment depthhef[mm]
263043
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
19,419,419,4
Partial safety factorγMS[-]
1,51,51,5
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
4,5813,8
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN]
223,5
Increasing factors for concrete C30/37Ψc[-]
1,171,171,17
Increasing factors for concrete C40/50Ψc[-]
1,321,321,32
Increasing factors for concrete C50/60Ψc[-]
1,421,421,42
Installation safety factorγinst[-]
1,01)1,01)1
CONCRETE CONE FAILURE
Factor for cracked concretekcr,N[-]
7,77,77,7
Factor for uncracked concretekucr,N[-]
111111
Spacingscr,N[mm]
7890129
Edge distanceccr,N[mm]
394564,5
Installation safety factorγinst[-]
1,01)1,01)1
CONCRETE SPLITTING FAILURE
Spacingscr,sp[mm]
8090130
Edge distanceccr,sp[mm]
404565
Installation safety factorγinst[-]
1,01)1,01)1
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
9,79,79,7
Ductility factork7[-]
111
Characteristic resistance with lever armMRk,s[Nm]
16,116,116,1
Partial safety factorγMS[-]
1,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
111
Installation safety factorγinst[-]
111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
354055
Anchor diameterdnom[mm]
666
Installation safety factorγinst[-]
111
1) Holes without cleaning γinst = 1,2
Size6
R (for EI) = 30 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,81,81,8
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,8
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,81,81,8
Characteristic resistance with lever armMRk,s[Nm]
1,51,51,5
R (for EI) = 60 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
1,41,41,4
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,8
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
1,41,41,4
Characteristic resistance with lever armMRk,s[Nm]
1,21,21,2
R (for EI) = 90 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
111
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,50,50,8
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
111
Characteristic resistance with lever armMRk,s[Nm]
0,80,80,8
R (for EI) = 120 min
Nominal embedment depthhnom[mm]
354055
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,80,80,8
PULL-OUT FAILURE
Characteristic resistanceNRk,p[kN]
0,40,40,7
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,80,80,8
Characteristic resistance with lever armMRk,s[Nm]
0,70,70,7
Size6
Nominal embedment depthhnom[mm]
4055
SEISMIC CATEGORY C1
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C1[kN]
19,419,4
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistance seismic C1NRk,p,C1[kN]
23,5
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C1[kN]
4,74,7

Approvals and publications

Technical library

(8)

Technical assessments(2)

ETA-23/0707 (2025-01-24) - Cracked and uncracked concrete

R-HLX - Concrete screw for use in cracked and uncracked concrete

ETA-24/1104 (2025-06-03) - Non-structural systems

Concrete screw for use in concrete for redundant non-structural systems

Declarations(2)

DoP-23/0707 R-HLX (ETA-23/0707)

DoP-23/0707 R-HLX (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

DoP-24/1104-R-HLX (ETA-24/1104 - Non-structural systems)

R-HLX - Cpncrete screw for use in concrete for redundant non-structural systems.

Certificates(3)

1488-CPR-1100/W (ETA-23/0707)

CPR (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete

1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)

CPR - ETA-24/1104 (2025-06-03) - Non-structural systems

EPD-R-HLX (2025-11-27)

Type III Environmental Declaration Certificate

Documents(1)

VDS CEA 4001 (2025-03-05)

Pipe hanger components for automatic sprinkler systems

Catalogues and product cards

(5)

Product cards(2)

Product card

Product card R-HLX hollow-core slab

Catalogues(3)

Catalogue Offer (overview) - EN

General Catalogue EN 2026/27

Specification Design Guide

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP