Zinc flake pan-head induction hardened concrete screw anchor R-HLX-P-ZF 6x60 mm - cardboard box - 100 pcs.
R-HLX-06X060-P-ZF
5906675656298
Define product parameters:
Contact with us and check out our terms of cooperation
R-HLX-06X060-P-ZF
5906675656298
Define product parameters:
Contact with us and check out our terms of cooperation
Contact with us and check out our terms of cooperation
Pan-Head Induction Hardened Concrete Screw Anchor

R-HLX High performed screwbolt
Innowacyjny_wkret_do_betonu_hartowany_indukcyjnie_RHLX_Rawlplug_KROTKI
Cracked concrete C20/25-C50/60
Non-cracked concrete C20/25-C50/60
Unreinforced concrete
Reinforced concrete
Hollow-core slab C30/37-C50/60
Approved surfaces
Balustrades
Concrete structures
Formwork
Gates
Scaffolding
Seats in public facilities
Storage racks
Temporary fixings
Drill the hole with a hammer drill (1a) ) to the required depth according to the table
Clean the hole (blow dust at least 4 times with the hand pump). When using a dust-free drill bit (1b), it is not necessary to clean the hole..
Tighten to the mounted element.
After the anchor is installed, it must not be possible to screw it in further. The screw head must be flush with the attached element and must not be damaged.
| Size | 6 | ||
Thread diameterd[mm] | 7,9 | 7,9 | 7,9 |
Hole diameter in substrated0[mm] | 6 | 6 | 6 |
Hole diameter in fixturedf[mm] | 9 | 9 | 9 |
External diameter of washerdw[mm] | 14,6 | 14,6 | 14,6 |
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
Min. hole depth in substrateh0,min[mm] | 45 | 50 | 65 |
Real hole depth in substrateh0[mm] | L+10-tfix | L+10-tfix | L+10-tfix |
Min. substrate thicknesshmin[mm] | 80 | 80 | 80 |
Min. edge distancecmin[mm] | 35 | 35 | 35 |
Min. spacingsmin[mm] | 35 | 35 | 35 |
Wrench sizeT[mm] | T30 | T30 | T30 |
Max. torque for impact screw driverTimp,max[Nm] | 250 | 250 | 250 |
| Size | 6 |
Nominal ultimate tensile strengthfuk[N/mm2] | 800 |
Nominal yield strengthfyk[N/mm2] | 640 |
Cross sectional area As[mm2] | 24,6 |
Elastic section modulusWel[mm3] | 17,24 |
Characteristic bending resistanceM0Rk,s[Nm] | 16,6 |
| Size | 6 | ||
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
| MEAN ULTIMATE RESISTANCE | |||
| TENSION LOAD | |||
| UNCRACKED CONCRETE | |||
Tension loadNRu,m[mm] | 8,32 | 11,09 | 18,99 |
| CRACKED CONCRETE | |||
Tension loadNRu,m[mm] | 4,02 | 7,11 | 10,88 |
| SHEAR LOAD | |||
| UNCRACKED CONCRETE | |||
Shear loadVRu,m[mm] | 8,95 | 10,67 | 10,67 |
| CRACKED CONCRETE | |||
Shear loadVRu,m[mm] | 6,3 | 7,81 | 10,67 |
| CHARACTERISTIC RESISTANCE | |||
| TENSION LOAD | |||
| UNCRACKED CONCRETE | |||
Tension loadNRk[mm] | 4,5 | 8 | 13,8 |
| CRACKED CONCRETE | |||
Tension loadNRk[mm] | 2 | 2 | 3,5 |
| SHEAR LOAD | |||
| UNCRACKED CONCRETE | |||
Shear loadVRk[mm] | 6,52 | 8,08 | 9,7 |
| CRACKED CONCRETE | |||
Shear loadVRk[mm] | 4,57 | 5,66 | 9,7 |
| DESIGN RESISTANCE | |||
| TENSION LOAD | |||
| UNCRACKED CONCRETE | |||
Tension loadNRd[mm] | 3 | 5,33 | 9,2 |
| CRACKED CONCRETE | |||
Tension loadNRd[mm] | 1,33 | 1,33 | 2,33 |
| SHEAR LOAD | |||
| UNCRACKED CONCRETE | |||
Shear loadVRd[mm] | 4,35 | 5,39 | 7,76 |
| CRACKED CONCRETE | |||
Shear loadVRd[mm] | 3,04 | 3,77 | 6,47 |
| RECOMMENDED LOAD | |||
| TENSION LOAD | |||
| UNCRACKED CONCRETE | |||
Tension loadNrec[mm] | 2,14 | 3,81 | 6,57 |
| CRACKED CONCRETE | |||
Tension loadNrec[mm] | 0,95 | 0,95 | 1,67 |
| SHEAR LOAD | |||
| UNCRACKED CONCRETE | |||
Shear loadVrec[mm] | 3,11 | 3,85 | 5,54 |
| CRACKED CONCRETE | |||
Shear loadVrec[mm] | 2,17 | 2,69 | 4,62 |
| Size | 6 | ||
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
Effective embedment depthhef[mm] | 26 | 30 | 43 |
| TENSION LOAD | |||
| STEEL FAILURE | |||
Characteristic resistanceNRk,s[kN] | 19,4 | 19,4 | 19,4 |
Partial safety factorγMS[-] | 1,5 | 1,5 | 1,5 |
| PULL-OUT FAILURE | |||
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN] | 4,5 | 8 | 13,8 |
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN] | 2 | 2 | 3,5 |
Increasing factors for concrete C30/37Ψc[-] | 1,17 | 1,17 | 1,17 |
Increasing factors for concrete C40/50Ψc[-] | 1,32 | 1,32 | 1,32 |
Increasing factors for concrete C50/60Ψc[-] | 1,42 | 1,42 | 1,42 |
Installation safety factorγinst[-] | 1,01) | 1,01) | 1 |
| CONCRETE CONE FAILURE | |||
Factor for cracked concretekcr,N[-] | 7,7 | 7,7 | 7,7 |
Factor for uncracked concretekucr,N[-] | 11 | 11 | 11 |
Spacingscr,N[mm] | 78 | 90 | 129 |
Edge distanceccr,N[mm] | 39 | 45 | 64,5 |
Installation safety factorγinst[-] | 1,01) | 1,01) | 1 |
| CONCRETE SPLITTING FAILURE | |||
Spacingscr,sp[mm] | 80 | 90 | 130 |
Edge distanceccr,sp[mm] | 40 | 45 | 65 |
Installation safety factorγinst[-] | 1,01) | 1,01) | 1 |
| SHEAR LOAD | |||
| STEEL FAILURE | |||
Characteristic resistance without lever armVRk,s[kN] | 9,7 | 9,7 | 9,7 |
Ductility factork7[-] | 1 | 1 | 1 |
Characteristic resistance with lever armMRk,s[Nm] | 16,1 | 16,1 | 16,1 |
Partial safety factorγMS[-] | 1,25 | 1,25 | 1,25 |
| CONCRETE PRY-OUT FAILURE | |||
Factork[-] | 1 | 1 | 1 |
Installation safety factorγinst[-] | 1 | 1 | 1 |
| CONCRETE EDGE FAILURE | |||
Effective length of anchorℓf[mm] | 35 | 40 | 55 |
Anchor diameterdnom[mm] | 6 | 6 | 6 |
Installation safety factorγinst[-] | 1 | 1 | 1 |
| 1) Holes without cleaning γinst = 1,2 | |||
| Size | 6 | ||
| R (for EI) = 30 min | |||
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
| TENSION LOAD | |||
| STEEL FAILURE | |||
Characteristic resistanceNRk,s[kN] | 1,8 | 1,8 | 1,8 |
| PULL-OUT FAILURE | |||
Characteristic resistanceNRk,p[kN] | 0,5 | 0,5 | 0,8 |
| SHEAR LOAD | |||
| STEEL FAILURE | |||
Characteristic resistance without lever armVRk,s[kN] | 1,8 | 1,8 | 1,8 |
Characteristic resistance with lever armMRk,s[Nm] | 1,5 | 1,5 | 1,5 |
| R (for EI) = 60 min | |||
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
| TENSION LOAD | |||
| STEEL FAILURE | |||
Characteristic resistanceNRk,s[kN] | 1,4 | 1,4 | 1,4 |
| PULL-OUT FAILURE | |||
Characteristic resistanceNRk,p[kN] | 0,5 | 0,5 | 0,8 |
| SHEAR LOAD | |||
| STEEL FAILURE | |||
Characteristic resistance without lever armVRk,s[kN] | 1,4 | 1,4 | 1,4 |
Characteristic resistance with lever armMRk,s[Nm] | 1,2 | 1,2 | 1,2 |
| R (for EI) = 90 min | |||
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
| TENSION LOAD | |||
| STEEL FAILURE | |||
Characteristic resistanceNRk,s[kN] | 1 | 1 | 1 |
| PULL-OUT FAILURE | |||
Characteristic resistanceNRk,p[kN] | 0,5 | 0,5 | 0,8 |
| SHEAR LOAD | |||
| STEEL FAILURE | |||
Characteristic resistance without lever armVRk,s[kN] | 1 | 1 | 1 |
Characteristic resistance with lever armMRk,s[Nm] | 0,8 | 0,8 | 0,8 |
| R (for EI) = 120 min | |||
Nominal embedment depthhnom[mm] | 35 | 40 | 55 |
| TENSION LOAD | |||
| STEEL FAILURE | |||
Characteristic resistanceNRk,s[kN] | 0,8 | 0,8 | 0,8 |
| PULL-OUT FAILURE | |||
Characteristic resistanceNRk,p[kN] | 0,4 | 0,4 | 0,7 |
| SHEAR LOAD | |||
| STEEL FAILURE | |||
Characteristic resistance without lever armVRk,s[kN] | 0,8 | 0,8 | 0,8 |
Characteristic resistance with lever armMRk,s[Nm] | 0,7 | 0,7 | 0,7 |
| Size | 6 | |
Nominal embedment depthhnom[mm] | 40 | 55 |
| SEISMIC CATEGORY C1 | ||
| TENSION LOAD, STEEL FAILURE | ||
Characteristic resistanceNRk,s,C1[kN] | 19,4 | 19,4 |
| TENSION LOAD, PULL-OUT FAILURE | ||
Characteristic resistance seismic C1NRk,p,C1[kN] | 2 | 3,5 |
| SHEAR LOAD, STEEL FAILURE | ||
Characteristic resistance without lever armVRk,s,C1[kN] | 4,7 | 4,7 |
(8)
1488-CPR-1100/W (ETA-23/0707)
CPR (ETA-23/0707 - 2025-01-24) - Concrete screw for use in cracked and uncracked concrete
1488-CPR-0745/Z (ETA-24/1104 - Non-structural systems)
CPR - ETA-24/1104 (2025-06-03) - Non-structural systems
EPD-R-HLX (2025-11-27)
Type III Environmental Declaration Certificate