1. Mainpage
  2. Products
  3. Anchors
  4. Chemical resin fixings
  5. Resin anchors for concrete
  6. Hybrid bonded anchor R-KER-II winter version - plastic cartouche - 400 ml

Hybrid bonded anchor R-KER-II winter version - plastic cartouche - 400 ml

Solid walls

R-KER-II-400-W

5906675432069

Hybrid bonded anchor for high loads based on styrene-free vinylester resin for concrete substrates

Define product parameters:

Bonded anchors version
Packaging
Packaging and quantity
Resin color
Weight and bulk packaging
  • Unit pack

    10.00 pcs.8.37 kg

  • Bulk pack

    10.00 pcs.8.37 kg

  • Pallet

    560.00 pcs.468.89 kg

Features

Hybrid bonded anchor for high loads based on styrene-free vinylester resin for concrete substrates

  • Approved for use in non-cracked concrete (EAD 330499-02-0601), working life up to 100 years.
  • High parameter stability at elevated temperatures.
  • For faster curing winter version of the resin can be used.
  • No need for hole cleaning when using Dustlessdrill bit.
  • Very high load capacity.
  • Unique soft foil pack for less waste.
  • Effortless extrusion due to the patented self-opening system with manual or battery dispenser guns.
  • The available fire testing report presents the anchor's performance in fire conditions, facilitating the project approval process by investors and building supervision.

Product video

R-KER II bonded anchor – installation and application – how to use the product – Rawlplug tutorial

Rawlplug Deep Anchorage and post-installed rebar accessories system

Jakzamontowa_konstrukcj_stalow__

Montaz_kotwy_chemicznej_obciazanie_ukladu

Rawlplug_Academy_jaki_otwor_pod_kotwe_chemiczna

Jakprawid_owowykona_g__bokiewklejaniepr_t_wzbrojeniowych_

Rawlplug_Academy_bledy_montazu_kotwy_chemicznej

Jakprawid_owou_y_kotwychemicznej_

Czymjestkotwachemicznaijakjeju_ywa__

R_KEM_II_jak_zamontowa_bojler

Rawlplug_Academy_jak_wyczyscic_otwor_pod_kotwe_chemiczna

RKEM_II_Zapowiedz_jak_zamontowac_bojler_za_pomoca_kotwy_chemicznej

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Approved surfaces

Applications

Anchoring glued in with reinforcing bars

Anchoring glued in with threaded rods

Brackets

Concrete structures

Elevators and escalators

Roads and bridges

Steel structures

Ventilated facades

Full list of variations

Substitutes

Services

Installation guide

Design data
SizeM8M10M12M16M20M24M30
Thread diameterd[mm]
8101216202430
Hole diameter in substrated0[mm]
10121418242835
Hole diameter in fixturedf[mm]
9121418222633
Min. installation depthhnom,min[mm]
606060608096120
Min. installation depthhnom,max[mm]
160200240320400480600
Min. hole depth in substrateh0[mm]
hnom + 5hnom + 5hnom + 5hnom + 5hnom + 5hnom + 5hnom + 5
Min. substrate thicknesshmin[mm]
hnom + 30 ≥
100
hnom + 30 ≥
100
hnom + 30 ≥
100
hnom + 2d0hnom + 2d0hnom + 2d0hnom + 2d0
Installation torqueTinst[Nm]
10204080120180200
Min. spacingsmin[mm]
40404050607085
Min. edge distancecmin[mm]
40404050607085
Concrete temperature [°C]-50+5+10+15+20+30
Max. processing time-[min]
403015852,52
Min. curing time [min]
14401809060604545
SizeM8M10M12M16M20M24M30
R-STUDS Metric Threaded Rods - Steel Class 5.8
Nominal ultimate tensile strengthfuk[N/mm2]
500500500500500500500
Nominal yield strengthfyk[N/mm2]
400400400400400400400
Cross sectional area As[mm2]
36,65884,3157245352,8559,8
Elastic section modulusWel[mm3]
31,262,3109,2277,55419351868
Characteristic bending resistanceM0Rk,s[Nm]
1937651663245611124
Design bending resistanceM[Nm]
153052133259449899
Allowable bending resistanceMrec[Nm]
11213795185321642
R-STUDS Metric Threaded Rods - Steel Class 8.8
Nominal ultimate tensile strengthfuk[N/mm2]
800800800800800800800
Nominal yield strengthfyk[N/mm2]
640640640640640640640
Cross sectional area As[mm2]
36,65884,3157245352,8559,8
Elastic section modulusWel[mm3]
31,262,3109,2277,55419351868
Characteristic bending resistanceM0Rk,s[Nm]
30601052665198981799
Design bending resistanceM[Nm]
2448842134167181439
Allowable bending resistanceMrec[Nm]
1734601522975131028
R-STUDS Metric Threaded Rods - Steel Grade A4
Nominal ultimate tensile strengthfuk[N/mm2]
700700700700700700700
Nominal yield strengthfyk[N/mm2]
450450450450450450450
Cross sectional area As[mm2]
36,65884,3157245352,8559,8
Elastic section modulusWel[mm3]
31,262,3109,2277,55419351868
Characteristic bending resistanceM0Rk,s[Nm]
2652922334547861574
Design bending resistanceM[Nm]
1734591492915041009
Allowable bending resistanceMrec[Nm]
122442107208360721
SizeM8M10M12M16M20M24M30
UNCRACKED CONCRETE C20/25
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
18,9030,4531,3731,3748,3063,4988,73
Maximum embedment depth-[kN]
18,9030,4544,1081,90128,10184,80294,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
30,4531,3731,3731,3748,3063,4988,73
Maximum embedment depth-[kN]
30,4548,3070,35132,30205,80296,10471,45
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
27,3031,3731,3731,3748,3063,4988,73
Maximum embedment depth-[kN]
27,3043,0561,95115,50179,55259,35412,65
SHEAR LOAD VRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
Maximum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
18,2728,9842,2162,7496,60126,98177,46
Maximum embedment depth-[kN]
18,2728,9842,2179,38123,48177,66282,87
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
16,3825,8337,1762,7496,60126,98177,46
Maximum embedment depth-[kN]
16,3825,8337,1769,30107,73155,61247,59
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
18,0022,8622,8622,8635,2046,2764,67
Maximum embedment depth-[kN]
18,0029,0042,0078,00122,00176,00280,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
22,8622,8622,8622,8635,2046,2764,67
Maximum embedment depth-[kN]
29,0046,0067,00126,00196,00282,00449,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
22,8622,8622,8622,8635,2046,2764,67
Maximum embedment depth-[kN]
26,0041,0059,00110,00171,00247,00393,00
SHEAR LOAD VRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00129,33
Maximum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00140,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,0023,0034,0045,7370,4092,54129,33
Maximum embedment depth-[kN]
15,0023,0034,0063,0098,00141,00224,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
13,0020,0029,0045,7370,4092,54129,33
Maximum embedment depth-[kN]
13,0020,0029,0055,0086,00124,00196,00
DESIGN RESISTANCE
TENSION LOAD NRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
12,0015,2415,2415,2423,4730,8543,11
Maximum embedment depth-[kN]
12,0019,3328,0052,0081,33117,33186,67
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,2415,2415,2415,2423,4730,8543,11
Maximum embedment depth-[kN]
19,3330,6744,6784,00130,67188,00299,33
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
13,9015,2415,2415,2423,4730,8543,11
Maximum embedment depth-[kN]
13,9021,9331,5558,8291,44132,09210,16
SHEAR LOAD VRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
7,2011,2016,8030,4846,9361,7086,22
Maximum embedment depth-[kN]
7,2011,2016,8031,2048,8070,40112,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
12,0018,4027,2030,4846,9361,7086,22
Maximum embedment depth-[kN]
12,0018,4027,2050,4078,40112,80179,20
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
8,3312,8218,5930,4846,9361,7086,22
Maximum embedment depth-[kN]
8,3312,8218,5935,2655,1379,49125,64
RECOMMENDED LOAD
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
8,5710,8910,8910,8916,7622,0330,79
Maximum embedment depth-[kN]
8,5713,8120,0037,1458,1083,81133,33
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
10,8910,8910,8910,8916,7622,0330,79
Maximum embedment depth-[kN]
13,8121,9031,9060,0093,33134,29213,81
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
9,9310,8910,8910,8916,7622,0330,79
Maximum embedment depth-[kN]
9,9315,6622,5442,0265,3294,35150,11
SHEAR LOAD Vrec
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
5,148,0012,0021,7733,5244,0761,59
Maximum embedment depth-[kN]
5,148,0012,0022,2934,8650,2980,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
8,5713,1419,4321,7733,5244,0761,59
Maximum embedment depth-[kN]
8,5713,1419,4336,0056,0080,57128,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
5,959,1613,2821,7733,5244,0761,59
Maximum embedment depth-[kN]
5,959,1613,2825,1839,3856,7889,74
SizeM8M10M12M16M20M24M30
CRACKED CONCRETE C20/25
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
18,9022,0822,0822,0833,9944,6862,44
Maximum embedment depth-[kN]
18,9030,4544,1081,90128,10184,80294,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
19,6022,0822,0822,0833,9944,6862,44
Maximum embedment depth-[kN]
30,4548,3070,35132,30205,80296,10367,57
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
19,6022,0822,0822,0833,9944,6862,44
Maximum embedment depth-[kN]
27,3043,0561,95115,50179,55259,35367,57
SHEAR LOAD VRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
11,3418,2726,4644,1567,9889,36124,88
Maximum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
18,2728,9842,2144,1567,9889,36124,88
Maximum embedment depth-[kN]
18,2728,9842,2179,38123,48177,66282,87
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
16,3825,8337,1744,1567,9889,36124,88
Maximum embedment depth-[kN]
16,3825,8337,1769,30107,73155,61247,59
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
15,0816,0016,0016,0024,6432,3945,27
Maximum embedment depth-[kN]
18,0029,0042,0078,00122,00176,00280,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,0816,0016,0016,0024,6432,3945,27
Maximum embedment depth-[kN]
29,0046,0067,00126,00188,50253,34282,74
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
15,0816,0016,0016,0024,6432,3945,27
Maximum embedment depth-[kN]
26,0041,0059,00110,00171,00247,00282,74
SHEAR LOAD VRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
9,0014,0021,0032,0149,2864,7890,53
Maximum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00140,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,0023,0032,0132,0149,2864,7890,53
Maximum embedment depth-[kN]
15,0023,0034,0063,0098,00141,00224,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
13,0020,0029,0032,0149,2864,7890,53
Maximum embedment depth-[kN]
13,0020,0029,0055,0086,00124,00196,00
DESIGN RESISTANCE
TENSION LOAD NRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
10,0510,6710,6710,6716,4321,5930,18
Maximum embedment depth-[kN]
12,0019,3328,0052,0081,33117,33186,67
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
10,0510,6710,6710,6716,4321,5930,18
Maximum embedment depth-[kN]
19,3330,6744,6784,00125,66168,89188,50
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
10,0510,6710,6710,6716,4321,5930,18
Maximum embedment depth-[kN]
13,9021,9331,5558,8291,44132,09188,50
SHEAR LOAD VRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
7,2011,2016,8021,3432,8543,1960,36
Maximum embedment depth-[kN]
7,2011,2016,8031,2048,8070,40112,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
12,0018,4021,3421,3432,8543,1960,36
Maximum embedment depth-[kN]
12,0018,4027,2050,4078,40112,80179,20
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
8,3312,8218,5921,3432,8543,1960,36
Maximum embedment depth-[kN]
8,3312,8218,5935,2655,1379,49125,64
RECOMMENDED LOAD
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
7,187,627,627,6211,7315,4221,56
Maximum embedment depth-[kN]
8,5713,8120,0037,1458,1083,81133,33
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
7,187,627,627,6211,7315,4221,56
Maximum embedment depth-[kN]
13,8121,9031,9060,0089,76120,64134,64
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
7,187,627,627,6211,7315,4221,56
Maximum embedment depth-[kN]
9,9315,6622,5442,0265,3294,35134,64
SHEAR LOAD Vrec
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
5,148,0012,0015,2423,4730,8543,11
Maximum embedment depth-[kN]
5,148,0012,0022,2934,8650,2980,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
8,5713,1415,2415,2423,4730,8543,11
Maximum embedment depth-[kN]
8,5713,1419,4336,0056,0080,57128,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
5,959,1613,2815,2423,4730,8543,11
Maximum embedment depth-[kN]
5,959,1613,2825,1839,3856,7889,74
SizeM8M10M12M16M20M24M30
TENSION LOAD
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistanceNRk,s[kN]
18,0029,0042,0078,00122,00176,00280,00
Partial safety factorγMS[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistanceNRk,s[kN]
29,0046,0067,00126,00196,00282,00448,00
Partial safety factorγMS[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistanceNRk,s[kN]
26,0041,0059,00110,00171,00247,00392,00
Partial safety factorγMS[-]
1,871,871,871,871,871,871,87
WORKING LIFE 50 YEARS
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; UNCRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
16,0015,0015,0013,0010,0010,008,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
16,0015,0015,0013,0010,0010,008,00
Characteristic bond resistance (120°C/80°C)τRk[N/mm2]
8,508,008,007,005,505,504,50
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; CRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
10,0011,0011,009,507,507,005,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
10,0011,0011,009,507,507,005,00
Characteristic bond resistance (120°C/80°C)τRk[N/mm2]
5,006,006,005,004,004,003,00
FACTORS
Factor of the influence of sustained load (40°C/24°C)Ψ0sus[-]
0,720,720,720,720,720,720,72
Factor of the influence of sustained load (80°C/50°C)Ψ0sus[-]
0,720,720,720,720,720,720,72
Factor of the influence of sustained load (120°C/80°C)Ψ0sus[-]
0,610,610,610,610,610,610,61
WORKING LIFE 100 YEARS
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; UNCRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
15,0015,0014,0013,0010,009,508,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
15,0015,0014,0013,0010,009,508,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; CRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
9,5010,0010,509,507,507,005,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
9,5010,0010,509,507,507,005,00
FACTORS
Factor of the influence of sustained load (40°C/24°C)Ψ0sus[-]
0,600,600,600,600,600,600,60
Factor of the influence of sustained load (80°C/50°C)Ψ0sus[-]
0,600,600,600,600,600,600,60
COMBINED PULL-OUT AND CONCRETE CONE FAILURE
Installation safety factorγ2[-]
1,001,001,001,001,001,001,00
Increasing factors for concrete C30/37Ψc[-]
1,041,041,041,041,041,041,04
Increasing factors for concrete C40/50Ψc[-]
1,071,071,071,071,071,071,07
Increasing factors for concrete C50/60Ψc[-]
1,091,091,091,091,091,091,09
CONCRETE CONE FAILURE
Installation safety factorγ2[-]
1,001,001,001,001,001,001,00
Factor for cracked concretekcr,N[-]
7,707,707,707,707,707,707,70
Factor for uncracked concretekucr,N[-]
11,0011,0011,0011,0011,0011,0011,00
Edge distanceccr,N[mm]
1,501,501,501,501,501,501,50
Spacingscr,N[mm]
3,003,003,003,003,003,003,00
CONCRETE SPLITTING FAILURE
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
SHEAR LOAD
R-STUDS Metric Threaded Rods - Steel Class 5.8
Characteristic resistance without lever armVRk,s[kN]
9,0014,0021,0039,0061,0088,00140,00
Ductility factork7[-]
1,01,01,01,01,01,01,0
Characteristic resistance with lever armMRk,s[Nm]
19,0037,0065,00166,00324,00561,001124,00
Partial safety factorγMS[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistance without lever armVRk,s[kN]
15,0023,0034,0063,0098,00141,00224,00
Ductility factork7[-]
1,01,01,01,01,01,01,0
Characteristic resistance with lever armMRk,s[Nm]
30,0060,00105,00266,00519,00898,001799,00
Partial safety factorγMS[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistance without lever armVRk,s[kN]
13,0020,0029,0055,0086,00124,00196,00
Ductility factork7[-]
1,01,01,01,01,01,01,0
Characteristic resistance with lever armMRk,s[Nm]
26,0052,0092,00233,00454,00786,001574,00
Partial safety factorγMS[-]
1,561,561,561,561,561,561,56
CONCRETE PRY-OUT FAILURE
Factork[-]
2,002,002,002,002,002,002,00
Installation safety factorγ2[-]
1,001,001,001,001,001,001,00
CONCRETE EDGE FAILURE
Anchor diameterdnom[mm]
8,0010,0012,0016,0020,0024,0030,00
Effective embedment depthhef[mm]
min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
SizeM8M10M12M16M20M24M30
TENSION LOAD FOR SEISMIC C1
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistanceNRk,s,C1[kN]
18,0029,0042,0078,00122,00176,00280,00
Partial safety factorγMsN,seisC1[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistanceNRk,s,C1[kN]
29,0046,0067,00126,00196,00282,00448,00
Partial safety factorγMsN,seisC1[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistanceNRk,s,C1[kN]
25,0040,0059,00109,00171,00247,00392,00
Partial safety factorγMsN,seisC1[-]
1,871,871,871,871,871,871,87
COMBINED PULL-OUT AND CONCRETE CONE FAILURE
WORKING LIFE 50 YEARS
Characteristic bond resistance (40°C/24°C)τRk,C1[N/mm2]
8,0010,0010,009,507,507,004,00
Characteristic bond resistance (80°C/50°C)τRk,C1[N/mm2]
8,0010,0010,009,507,507,004,00
Characteristic bond resistance (120°C/80°C)τRk,C1[N/mm2]
4,505,006,005,004,004,002,00
WORKING LIFE 100 YEARS
Characteristic bond resistance (40°C/24°C)τRk,C1[N/mm2]
8,009,0010,009,507,507,004,00
Characteristic bond resistance (80°C/50°C)τRk,C1[N/mm2]
8,009,0010,009,507,507,004,00
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
SHEAR LOAD FOR SEISMIC C1
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistance without lever armVRk,s,C1[kN]
6,3010,1014,7027,3042,7061,6098,00
Partial safety factorγMsV,seisC1[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistance without lever armVRk,s,C1[kN]
10,2016,1023,5044,1068,6098,70156,80
Partial safety factorγMsV,seisC1[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistance without lever armVRk,s,C1[kN]
9,1014,4020,7038,5059,9086,50137,40
Partial safety factorγMsV,seisC1[-]
1,561,561,561,561,561,561,56
SizeM12M16M20M24
TENSION LOAD FOR SEISMIC C2
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistanceNRk,s,C2[kN]
42,0078,00122,00176,00
Partial safety factorγMsN,seisC2[-]
1,501,501,501,50
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistanceNRk,s,C2[kN]
67,00126,00196,00282,00
Partial safety factorγMsN,seisC2[-]
1,501,501,501,50
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistanceNRk,s,C2[kN]
59,00109,00171,00247,00
Partial safety factorγMsN,seisC2[-]
1,871,871,871,87
COMBINED PULL-OUT AND CONCRETE CONE FAILURE
Characteristic bond resistance (40°C/24°C)τRk,C2[N/mm2]
5,653,935,183,65
Characteristic bond resistance (80°C/50°C)τRk,C2[N/mm2]
5,033,504,613,25
Installation safety factorγinst[-]
1,001,001,001,00
SHEAR LOAD FOR SEISMIC C2
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistance without lever armVRk,s,C2[kN]
11,6013,7026,3047,00
Partial safety factorγMsV,seisC2[-]
1,251,251,251,25
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistance without lever armVRk,s,C2[kN]
18,5022,0042,1075,10
Partial safety factorγMsV,seisC2[-]
1,251,251,251,25
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistance without lever armVRk,s,C2[kN]
15,8019,2036,9066,00
Partial safety factorγMsV,seisC2[-]
1,561,561,561,56

Approvals and publications

Technical library

(23)

Technical assessments(6)

ETA-21/0242 (2024-12-30)

R-KER-II - Bonded anchors for use in concrete

ETA-17/0874 (2018-12-28)

Post-installed rebar connections with R-KER-II-S injection mortar

UKTA-0836-22/6130 (2022-09-15)

R-KER-II - Bonded fasteners for use in concrete

UKTA-0836-22/6128 (2022-07-19)

R-KER-II-S for rebar connections

KOT_2018_0134

IBDiM-KOT-2018/0134w2

ITB_KOT_2020_1166w3_2025_08_11_COPYECOII

ITB-KOT-2020/1166

Declarations(5)

DoP-21/0242-R-KER-II - ETA-21/0242 (2024-12-30)

R-KER-II - Bonded anchor with threaded rod, rod with inner thread and rebar for use in concrete.

DoP-17/0874-R-KER-II-S - ETA-17/0874 (2018-12-28)

Post-installed rebar connections with R-KER-II-S injection mortar

UKTA-DoP-22/6130 - UKTA-0836-22/6130 (2022-09-15)

R-KER-II - Bonded fasteners for use in concrete

UKTA-DoP-22/6128-R-KER-II-S - UKTA-0836-22/6128 (2022-07-19)

R-KER-II-S for rebar connections

KDWU_2018_0134_1

KDWU-2018-0134-2-SYSTEM RAWLPLUG

Certificates(7)

1488-CPR-0945/W - ETA-21/0242 (2024-12-30)

R-KER-II - Bonded anchors for use in concrete

1488-CPR-0748/W - ETA-17/0874 (2018-12-28)

Post-installed rebar connections with R-KER-II-S injection mortar

UK 0836-CPR-23/P6730 - UKTA-0836-22/6130 (2022-09-15)

R-KER-II - Bonded fasteners for use in concrete

UK 0836-CPR-23/P6760 - UKTA-0836-22/6128 (2022-07-19)

R-KER-II-S for rebar connections

UWB_IBDiM_KOT_2018_0134w2_2018_04_18_2023_07_10_

020-UWB-3059/W

UWB_ITB_KOT_2020_1166w3_2025_08_11_COPYECOII

020-UWB-3123/W

EPD - 03-08/2026 - VINYLESTER ANCHORS (2026-08-18)

Vinylester anchors - Świadectwo deklaracji środowiskowej III typu

Documents(5)

MSDS - R-KER-II, R-KER-II-S, R-KER-II-W (2025-05-26)

R-KER-II - Bonded fasteners for use in concrete

MSDS - R-KER-II, R-KER-II-S, R-KER-II-W - FOIL SYSTEM (2025-05-26)

R-KER-II - Bonded fasteners for use in concrete

AtestHigieniczny_R_KER_II_2020

B-BK-60111-0519-2025

VOC Emission Test Report - R-KER II (2017-02-20)

R-KER-II - Bonded fasteners for use in concrete

15092025-R-KERII-S - Fire resistance

R-KERII-S – Statement of essential characteristics under fire exposure for structural anchorages with post-installed reinforcing bars.

Catalogues and product cards

(8)

Product cards(4)

Product card R-KER-II version rebar as post-installed rebar

Product card R-KER-II version rebar for concrete substrate

Product card R-KER-II version socket for concrete substrate

Product card R-KER-II version threaded rods for concrete substrate

Catalogues(4)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Leaflet R-KERII

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP