| R-OCF d x L | |
Thickness of metal member or sheetingtI[mm] | 0,40 | 0,50 | 0,63 | 0,75 | 0,88 | 1,00 |
| TENSION LOAD |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 4,8 without washer) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,61 | 0,61 | 0,61 | 0,61 | 0,61 | 0,61 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,62 | 0,62 | 0,62 | 0,62 | 0,62 | 0,62 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,81 | 0,81 | 0,81 | 0,81 | 0,81 | 0,81 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,20 | 1,23 | 1,23 | 1,23 | 1,23 | 1,23 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,202) | 1,232) | 1,232) | 1,232) | 1,232) | 1,232) |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,20 | 1,37 | 1,67 | 1,71 | 1,71 | 1,71 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 4,8 with washer ≥ Ø14) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,61 | 0,61 | 0,61 | 0,61 | 0,61 | 0,61 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,62 | 0,62 | 0,62 | 0,62 | 0,62 | 0,62 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,81 | 0,81 | 0,81 | 0,81 | 0,81 | 0,81 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,23 | 1,23 | 1,23 | 1,23 | 1,23 | 1,23 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,232) | 1,232) | 1,232) | 1,232) | 1,232) | 1,232) |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,57 | 1,71 | 1,71 | 1,71 | 1,71 | 1,71 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 6,0 without washer) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 6,0 with washer ≥ Ø14) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,70 | 0,70 | 0,70 | 0,70 | 0,70 | 0,70 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,82 | 0,82 | 0,82 | 0,82 | 0,82 | 0,82 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,98 | 1,12 | 1,12 | 1,12 | 1,12 | 1,12 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 0,98 | 1,53 | 1,53 | 1,53 | 1,53 | 1,53 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 0,98 | 1,55 | 1,55 | 1,55 | 1,55 | 1,55 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 0,98 | 1,66 | 2,05 | 2,05 | 2,05 | 2,05 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 6,0 with washer ≥ Ø16) 1) |
Thickness of steel substructure tII = 0,40mmNRk[kN] | 0,70 | 0,70 | 0,70 | 0,70 | 0,70 | 0,70 |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,82 | 0,82 | 0,82 | 0,82 | 0,82 | 0,82 |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 1,12 | 1,12 | 1,12 | 1,12 | 1,12 | 1,12 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,20 | 1,53 | 1,53 | 1,53 | 1,53 | 1,53 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,20 | 1,55 | 1,55 | 1,55 | 1,55 | 1,55 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,20 | 1,83 | 2,05 | 2,05 | 2,05 | 2,05 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCF 4,8 without washer) |
Characteristic resistanceNRk,I,k[kN] | 1,20 | 1,37 | 1,67 | 1,95 | 1,952) | 3,18 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCF 4,8 with washer ≥ Ø14) |
Characteristic resistanceNRk,I,k[kN] | 1,57 | 2,08 | 2,67 | 2,94 | 2,942) | 2,94 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCF 6,0 without washer) |
Characteristic resistanceNRk,I,k[kN] | 0,21 | 0,24 | 0,28 | 0,46 | 0,46 | 0,57 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCF 6,0 with washer ≥ Ø14) |
Characteristic resistanceNRk,I,k[kN] | 0,98 | 1,66 | 2,31 | 2,87 | 2,87 | 3,26 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| PULL-THROUGH FAILURE (screw R-OCF 6,0 with washer ≥ Ø16) |
Characteristic resistanceNRk,I,k[kN] | 1,20 | 1,83 | 2,51 | 3,20 | 3,20 | 3,64 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - PULL-OUT FAILURE (screw R-OCF 4,8 without or with washer ≥ Ø14) |
Thickness of steel substructure tII = 0,40mmNRk,II,k[kN] | 0,61 | 0,61 | 0,61 | 0,61 | 0,61 | 0,61 |
Thickness of steel substructure tII = 0,50mmNRk,II,k[kN] | 0,62 | 0,62 | 0,62 | 0,62 | 0,62 | 0,62 |
Thickness of steel substructure tII = 0,63mmNRk,II,k[kN] | 0,81 | 0,81 | 0,81 | 0,81 | 0,81 | 0,81 |
Thickness of steel substructure tII = 0,75mmNRk,II,k[kN] | 1,23 | 1,23 | 1,23 | 1,23 | 1,23 | 1,23 |
Thickness of steel substructure tII = 0,88mmNRk,II,k[kN] | 1,232) | 1,232) | 1,232) | 1,232) | 1,232) | 1,232) |
Thickness of steel substructure tII = 1,00mmNRk,II,k[kN] | 1,20 | 1,37 | 1,67 | 1,71 | 1,71 | 1,71 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - PULL-OUT FAILURE (screw R-OCF 6,0 without or with washer ≥ Ø14 or Ø16) |
Thickness of steel substructure tII = 0,40mmNRk,II,k[kN] | 0,70 | 0,70 | 0,70 | 0,70 | 0,70 | 0,70 |
Thickness of steel substructure tII = 0,50mmNRk,II,k[kN] | 0,82 | 0,82 | 0,82 | 0,82 | 0,82 | 0,82 |
Thickness of steel substructure tII = 0,63mmNRk,II,k[kN] | 1,12 | 1,12 | 1,12 | 1,12 | 1,12 | 1,12 |
Thickness of steel substructure tII = 0,75mmNRk,II,k[kN] | 1,53 | 1,53 | 1,53 | 1,53 | 1,53 | 1,53 |
Thickness of steel substructure tII = 0,88mmNRk,II,k[kN] | 1,55 | 1,55 | 1,55 | 1,55 | 1,55 | 1,55 |
Thickness of steel substructure tII = 1,00mmNRk,II,k[kN] | 2,05 | 2,05 | 2,05 | 2,05 | 2,05 | 2,05 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| SHEAR LOAD |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 4,8 without or with washer ≥ Ø14) |
Thickness of steel substructure tII = 0,40mmVRk[kN] | 0,58 | 0,58 | 0,58 | 0,58 | 0,58 | 0,58 |
Thickness of steel substructure tII = 0,50mmVRk[kN] | 0,58 | 0,66 | 0,66 | 0,66 | 0,66 | 0,66 |
Thickness of steel substructure tII = 0,63mmVRk[kN] | 0,58 | 0,66 | 1,00 | 1,00 | 1,00 | 1,00 |
Thickness of steel substructure tII = 0,75mmVRk[kN] | 0,58 | 0,66 | 1,00 | 1,55 | 1,55 | 1,55 |
Thickness of steel substructure tII = 0,88mmVRk[kN] | 0,582) | 0,662) | 1,002) | 1,552) | 1,552) | 1,552) |
Thickness of steel substructure tII = 1,00mmVRk[kN] | 0,58 | 0,66 | 1,00 | 1,55 | 2,16 | 2,16 |
| CHARACTERISTIC RESISTANCE - CONNECTION FAILURE (screw R-OCF 6,0 without or with washer ≥ Ø14 or Ø16) |
Thickness of steel substructure tII = 0,40mmVRk[kN] | 0,87 | 0,87 | 0,87 | 0,87 | 0,87 | 0,87 |
Thickness of steel substructure tII = 0,50mmVRk[kN] | 0,87 | 1,51 | 1,51 | 1,51 | 1,51 | 1,51 |
Thickness of steel substructure tII = 0,63mmVRk[kN] | 0,87 | 1,51 | 1,69 | 1,69 | 1,69 | 1,69 |
Thickness of steel substructure tII = 0,75mmVRk[kN] | 0,87 | 1,51 | 1,69 | 2,17 | 2,17 | 2,17 |
Thickness of steel substructure tII = 0,88mmVRk[kN] | 0,87 | 1,51 | 1,69 | 2,17 | 2,17 | 2,17 |
Thickness of steel substructure tII = 1,00mmVRk[kN] | 0,87 | 1,51 | 1,69 | 2,17 | 2,17 | 2,3 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 | 1,33 |
| 1) min (NRk,I,k ; NRk,II,k) | | | | | | |
| 2) Not assessed | | | | | | |