| Type of fixing | R-WO-T | R-WX-T 4.8 | R-WX-T 6.0 |
| TENSION LOAD |
| R-POK-040 / R-POK-041 + SCREW |
| CHARACTERISTIC RESISTANCE - STEEL DECK S280GD |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,61 | - | - |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,83 | 0,74 | 1,21 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,19 | 1,00 | 1,34 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,22 | 1,08 | 1,45 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,59 | 1,50 | 2,35 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | - | 1,86 | 2,92 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | - | 2,60 | 3,74 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - STEEL DECK S320GD |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,66 | - | - |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,90 | 0,80 | 1,31 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,29 | 1,08 | 1,45 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,32 | 1,17 | 1,57 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,73 | 1,62 | 2,11 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | - | 2,01 | 2,69 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | - | 2,82 | 3,36 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - STEEL DECK S350GD |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,71 | - | - |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,97 | 0,87 | 1,41 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,38 | 1,16 | 1,56 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,41 | 1,26 | 1,69 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,85 | 1,74 | 2,27 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | - | 2,17 | 2,89 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | - | 3,04 | 3,62 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 |
| R-POK-06 + SCREW |
| CHARACTERISTIC RESISTANCE - STEEL DECK S280GD |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,61 | - | - |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,83 | 0,74 | 1,21 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,19 | 1,00 | 1,34 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,22 | 1,08 | 1,45 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,59 | 1,50 | 2,35 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | - | 1,86 | 2,54 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | - | 2,54 | 2,54 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - STEEL DECK S320GD |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,66 | - | - |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,90 | 0,8 | 1,31 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,29 | 1,08 | 1,45 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,32 | 1,17 | 1,57 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,73 | 1,62 | 2,11 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | - | 2,01 | 2,54 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | - | 2,54 | 2,54 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 |
| CHARACTERISTIC RESISTANCE - STEEL DECK S350GD |
Thickness of steel substructure tII = 0,50mmNRk[kN] | 0,71 | - | - |
Thickness of steel substructure tII = 0,63mmNRk[kN] | 0,97 | 0,87 | 1,41 |
Thickness of steel substructure tII = 0,75mmNRk[kN] | 1,38 | 1,16 | 1,56 |
Thickness of steel substructure tII = 0,88mmNRk[kN] | 1,41 | 1,26 | 1,69 |
Thickness of steel substructure tII = 1,00mmNRk[kN] | 1,85 | 1,74 | 2,27 |
Thickness of steel substructure tII = 1,25mmNRk[kN] | - | 2,17 | 2,54 |
Thickness of steel substructure tII = 1,50mmNRk[kN] | - | 2,54 | 2,54 |
Partial safety factorγM[-] | 1,33 | 1,33 | 1,33 |