1. Mainpage
  2. R-TFIX-8S-X Setting tool TX40 for countersunk installation, black - cardboard box - 1 pc.

R-TFIX-8S-X Setting tool TX40 for countersunk installation, black - cardboard box - 1 pc.

Universal

R-TFIX-TOOL-BLACK

5906675412276

TX40 Setting tool with integrated disc for countersunk installation of screw-in fixing R-TFIX-8SX

Define product parameters:

Packaging and quantity
Weight and bulk packaging
  • Unit pack

    1.00 pcs.0.10 kg

  • Bulk pack

    16.00 pcs.

  • Pallet

    384.00 pcs.

Related products

Rawlplug SDS Plus Rebar Drill Bit 8.0 x 150 x 210mm, PGM Approved - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x335 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x235 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x355 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x195 mm - cardboard box - 200 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, white - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x295 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

R-TFIX CAP For Mineral Wool, 63/10 Brown - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x255 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x275 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x155 mm - cardboard box - 200 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x215 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Features

TX40 Setting tool with integrated disc for countersunk installation of screw-in fixing R-TFIX-8SX

  • Ideal design of TX40 bit perfect suited to the screw-in R-TFIX-8S-X allows easy and stable installation.
  • Torx-40 bit type.
  • User-friendly - enables fast installation.
  • Integrated disc facilitates optimum R-TFIX-8S-X countersunk installation, for the perfect flush with the surface of the insulation it is necessery to use additional insulation cap R-TFIX-CAP63.

Product video

R-TFIX-8S-X: montaż zagłębiony w wełnie mineralnej

Substrates

Mineral wool boards

Mineral wool boards

Polystyrene (EPS) boards

Polystyrene (EPS) boards

Approved surfaces

Applications

Facades - thermal insulation systems

Full list of variations

Type of package
Piece. per pack.
Index
EAN

Cardboard box

1R-TFIX-TOOL-BLACK5906675412276

Contact with us and check out our terms of cooperation

Substitutes

Services

Design Consulting

Design Consulting

Training at the Rawlplug Academy center

Training at the Rawlplug Academy center

Technical Support 2

Technical Support 2

Rawlplug Academy

Rawlplug Academy

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Clean drilled hole 3 times.

3

Insert the R-TFIX-TOOL-BLACK into the head of the R-TFIX-8S-X screw with plate R-KWX.

4

When tightening, press the tip, keeping it precisely perpendicular to the elevation.

5

Tighten the plug screw until the appropriate embedment depth is reached (the plate should be on one surface with the thermal insulation layer).

6

After fixing the connector, close the hole with a mineral wool plug.

7

Properly installed R-TFIX-8SX with KCX Clamping Collar.

Installation data

Approvals and publications

Catalogues and product cards

(1)

Product cards(1)

Product cart

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2025 Koelner Rawlplug IP