1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Througbolts
  6. Throughbolts XPT
  7. R-XPT Throughbolt M10 x 95mm, Zinc Plated - cardboard box - 50 pcs.

R-XPT Throughbolt M10 x 95mm, Zinc Plated - cardboard box - 50 pcs.

Solid walls
Outlet

R-XPT-10095/25

5906675233598

Throughbolt for non-cracked concrete

Define product parameters:

Diameter
Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    50.00 pcs.3.11 kg

  • Bulk pack

    50.00 pcs.3.11 kg

  • Pallet

    8000.00 pcs.497.60 kg

Features

Throughbolt for non-cracked concrete

  • Optimized expander design with six grip features allows for a high load-bearing capacity.
  • High quality with cost effectiveness.
  • Design allows drilling and installing directly through the fixture and helps to reduce installation effort.
  • Embedment depth markings help to ensure precise installation of the anchor.
  • Cold formed body ensures consistent dimensional accuracy.
  • Simple through-installation (drilling and installation through fixed material).
  • Suitable for reduced embedment to avoid contact with reinforcement.

Product video

rawlplug_rxpt_throughb

Rawlplug Academy: czym jest i jak działa kotwa mechaniczna?

Substrates

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Concrete

Concrete

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Balustrades

Handrails

Poles and road signs

Profiled and cover sheets

Steel structures

Storage racks

Ventilated facades

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Blow out the dust at least 4 times with the hand pump.

3

Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached.

4

Tighten to the recommended torque.

5

The anchor is properly fixed in the concrete base.

Installation data
Design data
SizeM8M10M12M16M20
Thread diameterd[mm]
810121620
Hole diameter in substrated0[mm]
810121620
Hole diameter in fixturedf[mm]
912141822
Installation torqueTinst[Nm]
153050100200
Wrench sizeSw[mm]
1317192430
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
656990110135
Min. installation depthhnom,s[mm]
555980100119
Min. substrate thicknesshmin,s[mm]
100100136170198
Min. edge distancecmin[mm]
40506580100
For spacing distancess ≥[mm]
10090100150200
Min. spacingsmin[mm]
50557590140
For edge distancesc ≥[mm]
556590105160
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
50597090115
Min. installation depthhnom,r[mm]
4049608099
Min. substrate thicknesshmin,r[mm]
100100100130158
Min. edge distancecmin[mm]
4065100100125
For spacing distancess ≥[mm]
10055100100125
Min. spacingsmin[mm]
4555100100125
For edge distancesc ≥[mm]
5065100100125
SizeM8M10M12M16M20
Nominal ultimate tensile strengthfuk[N/mm2]
650650650650650
Nominal yield strengthfyk[N/mm2]
520520520520520
Cross sectional area As[mm2]
26,942,461,5109,3166,8
Elastic section modulusWel[mm3]
31,2462,32109,2277,54544,4
Characteristic bending resistanceM0Rk,s[Nm]
22,544,978,6199,8392
Design bending resistanceM[Nm]
1835,962,8159,8313,6
SizeM8M10M12M16M20
Standard embedment depthhnom[mm]
555980100119
Reduced embedment depthhnom[mm]
4049608099
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD VRu,m
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD VRk
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
DESIGN RESISTANCE
TENSION LOAD NRd
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD VRd
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
RECOMMENDED LOAD
TENSION LOAD Nrec
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SHEAR LOAD Vrec
UNCRACKED CONCRETE
STANDARD EMBEDMENT DEPTH
REDUCED EMBEDMENT DEPTH
SizeM8M10M12M16M20
Effective embedment depthhef[mm]
32473949486865857999
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
17,517,527,627,640407171108,4108,4
Partial safety factorγMS[-]
1,51,51,51,51,51,51,51,51,51,5
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
912915162428403644
Installation safety factorγinst[-]
1111111111
Increasing factors for concrete C30/37Ψc[-]
1,231,161,231,231,211,231,231,231,231,23
Increasing factors for concrete C40/50Ψc[-]
1,431,281,431,431,391,431,431,431,431,43
Increasing factors for concrete C50/60Ψc[-]
1,581,41,581,581,521,581,581,581,581,58
CONCRETE CONE FAILURE
Factor for uncracked concretekucr,N[-]
11111111111111111111
Installation safety factorγinst[-]
1111111111
Spacingscr,N[mm]
96141117147144204195255237297
Edge distanceccr,N[mm]
487159747210298149119149
CONCRETE SPLITTING FAILURE
Spacingscr,N[mm]
160240200260250370360430410530
Edge distanceccr,N[mm]
80120100130125185180215205265
Installation safety factorγinst[-]
1111111111
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armV0Rk,s[kN]
111117,417,425,325,347,147,173,573,5
Ductility factork7[-]
1111111111
Characteristic resistance with lever armMRk,s[Nm]
222245457979200200392392
Partial safety factorγMS[-]
1,251,251,251,251,251,251,251,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
1111122222
Installation safety factorγinst[-]
1111111111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
32473949486865857999
Anchor diameterdnom[mm]
881010121216162020
Installation safety factorγinst[-]
1111111111

Approvals and publications

Technical library

(5)

Technical assessments(2)

ETA-17/0183 (2023-04-27)

R-XPT - Torque controlled expansion anchor for use in uncracked concrete.

UKTA-0836-22/6201 (2022-11-22)

R-XPT - Torque controlled expansion anchor for use in uncracked concrete.

Declarations(2)

DoP-17/0183-R-XPT - ETA-17/0183 (2023-04-27)

R-XPT - Torque controlled expansion anchor for use in uncracked concrete.

UKTA-DoP-22/6201-R-XPT - UKTA-22/6201 (2022-11-22)

R-XPT - Torque controlled expansion anchor for use in uncracked concrete.

Certificates(1)

1488-CPR-0632/W - ETA-17/0183 (2023-04-27)

R-XPT - Torque controlled expansion anchor for use in uncracked concrete.

Catalogues and product cards

(4)

Product cards(1)

Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP