  6. Stainless wedge anchor with internal thread R-DCA-A4 M8 mm - cardboard box - 100 pcs.

Stainless wedge anchor with internal thread R-DCA-A4 M8 mm - cardboard box - 100 pcs.

Solid walls

R-DCA-08-30-A4

5010445776205

RawlplugRawl

Internally threaded stainless steel wedge anchor

Define product parameters:

Length
Metric diameter
Coating
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.1.22 kg

  • Bulk pack

    1600.00 pcs.19.52 kg

  • Pallet

    72000.00 pcs.903.40 kg

Features

Internally threaded stainless steel wedge anchor

  • Product is covered with European Technical Assessment for multi-point non-structural fixings.
  • Stainless steel material for high resistance to corrosion.
  • Easy to install by hammer action and manual setting tool.
  • Product was tested for construction fixing.
  • High performance in cracked and non-cracked concrete confirmed by ETA.
  • Product recommended for applications requiring fire resistance.
  • Slotted sleeve and internal wedge component together facilitate easy setting and expansion.

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Approved surfaces

Applications

Air conditioning / ventilation

Electrical Installations

Pipelines

Sprinkler installations

Steel structures

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole and clean it up.

2

Blow out dust at least 4 times with a hand pump.

3

Insert the anchor into the hole and hammer it in until it is flush with the substrate.

4

By striking the special hammer with the hammer, expand the anchor in the hole.

5

Place the element to be fastened, insert the screw or threaded rod and tighten to the required torque.

Installation data
Design data
SizeM6/25M8/30M10/40M12/50M16/65
Thread diameterd[mm]
68101216
Hole diameter in substrated0[mm]
810121520
Hole diameter in fixturedf[mm]
79121418
Max. installation torqueTinst[Nm]
4,511223898
Internal thread lengthlg[mm]
1114192528
Min. hole depth in substrateh0[mm]
2732425267
Min. installation depthhnom[mm]
2530405065
Min. substrate thicknesshmin[mm]
808080100130
Min. spacingsmin[mm]
200200200200260
Min. edge distancecmin[mm]
150150150150195
SizeM6/25M8/30M10/40M12/50M16/65
R-STUDS Metric Threaded Rods - Steel Class A4-70
Nominal ultimate tensile strengthfuk[N/mm2]
500500500500500
Nominal yield strengthfyk[N/mm2]
210210210210210
Cross sectional area As[mm2]
20,136,65884,3156,7
Elastic section modulusWel[mm3]
21,231,262,3109,1276,6
Characteristic bending resistanceM0Rk,s[Nm]
11265292233
Design bending resistanceM[Nm]
8,820,841,673,6186,4
SizeM6/25M8/30M10/40M12/50M16/65
Nominal embedment depthhnom[mm]
2530405065
CHARACTERISTIC LOAD
TENSION AND SHEAR LOAD FRk
Uncracked and cracked concrete C12/15-[kN]
0,751,52,53,56,5
Uncracked and cracked concrete C20/25 - C50/60-[kN]
1234,58
DESIGN LOAD
TENSION AND SHEAR LOAD FRd
Uncracked and cracked concrete C12/15-[kN]
0,420,831,391,943,61
Uncracked and cracked concrete C20/25 - C50/60-[kN]
0,561,111,672,54,44
RECOMMENDED LOAD
TENSION AND SHEAR LOAD Frec
Uncracked and cracked concrete C12/15-[kN]
0,30,60,991,392,58
Uncracked and cracked concrete C20/25 - C50/60-[kN]
0,40,791,191,793,17
SizeM6/25M8/30M10/40M12/50M16/65
Effective embedment depthhef[mm]
2530405065
TENSION AND SHEAR LOAD
CRACKED AND UNCRACKED CONCRETE
Characteristic resistance - concrete C12/15F0Rk[kN]
0,81,52,53,56,5
Characteristic resistance - concrete C20/25 - C50/60F0Rk[kN]
1234,58
Installation safety factorγinst[-]
1,21,21,21,21,2
Spacingscr[mm]
200200200200260
Edge distanceccr[mm]
150150150150195
Characteristic resistance with lever arm (Steel class A4-70)M0Rk,s[Nm]
11265292233
Partial safety factorγMS[-]
1,251,251,251,251,25
SizeM6/25M8/30M10/40M12/50M16/65
Effective embedment depthhef[mm]
2530405065
Edge distance 1)ccr,fi[mm]
506080100130
Spacingscr,fi[mm]
100120160200260
TENSION AND SHEAR LOAD
R (for EI) = 30 min
Characteristic resistanceNRk,fi[kN]
-0,50,81,12,1
R (for EI) = 60 min
Characteristic resistanceNRk,fi[kN]
-0,50,81,12,1
R (for EI) = 90 min
Characteristic resistanceNRk,fi[kN]
-0,50,81,12,1
R (for EI) = 120 min
Characteristic resistanceNRk,fi[kN]
-0,40,60,91,6
1) In case of fire attack from more than one side, the edge distance shall be ≥ 300 mm

Approvals and publications

Technical library

(8)

Technical assessments(3)

ETA-13/0584

Fasteners for use in concrete for redundant non-structural applications

KOT-2017/0165

ITB-KOT-2017/0165w3

UKTA-22/6371

UKTA-22/6371

Declarations(3)

DoP-13/0584 R-DCA-A4

KDWU-2017-0165-R-DCA

UKTA-DoP-22/6371-R-DCA-A4

Certificates(2)

1488-CPR-0328/Z

CPR

020_UWB_2994_W

020-UWB-2994/W

Catalogues and product cards

(4)

Product cards(1)

Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP