1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Througbolts
  6. Throughbolts HPT
  7. Stainless steel A4 throughbolt R-HPTIIA4 8x85 mm - cardboard box - 100 pcs.

Stainless steel A4 throughbolt R-HPTIIA4 8x85 mm - cardboard box - 100 pcs.

Solid walls

R-HPTIIA4-08085/20

5906675046433

Stainless steel throughbolt anchor for cracked and non-cracked concrete

Define product parameters:

Diameter
Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    100.00 pcs.3.38 kg

  • Bulk pack

    100.00 pcs.3.38 kg

  • Pallet

    16000.00 pcs.541.44 kg

This product has been withdrawn from sale.

Features

Stainless steel throughbolt anchor for cracked and non-cracked concrete

  • Stainless steel anchor for the highest corrosion resistance.
  • High performance in cracked and non-cracked concrete confirmed by ETA Option 1.
  • Highest quality ensures maximum load capability.
  • For applications requiring fire resistance up to 120 minutes.
  • Suitable for reduced embedment to avoid contact with reinforcement.
  • Embedment depth markings help to ensure precise installation of the anchor.
  • Design of R-HPTII allows drilling and installing directly through the fixture and helps to reduce installation time.
  • Suitable for installation in corrosive environments category C1, C2, C3,C4 and C5.
  • Anchors can be used in earthquake risk zones - seismic category C1 and C2.

Product video

rawlplug_rhptiia4_stai

mechanical_anchoring_i

Rawlplug Academy: czym jest i jak działa kotwa mechaniczna?

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Reinforced concrete

Reinforced concrete

Unreinforced concrete

Unreinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Elevators and escalators

Gates

Handrails

Seats in public facilities

Steel structures

Storage racks

Ventilated facades

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Blow out the dust at least 4 times with the hand pump.

3

Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached.

4

Using a torque wrench, tighten the nut to the required torque.

5

The anchor is correctly fixed.

Installation data
Design data
SizeM8M10M12M16
Thread diameterd[mm]
8101216
Hole diameter in substrated0[mm]
8101216
Hole diameter in fixturedf[mm]
9121418
Installation torqueTinst[Nm]
103050100
Wrench sizeSw[mm]
13171924
STANDARD EMBEDMENT DEPTH
Min. hole depth in substrateh0,s[mm]
657990110
Min. installation depthhnom,s[mm]
55697090
Min. substrate thicknesshmin,s[mm]
100120140170
Min. spacing (Uncracked concrete)smin,s[mm]
557090135
Min. spacing (Cracked concrete)smin,s[mm]
557090135
Min. edge distance (Uncracked concrete)cmin,s[mm]
40505580
Min. edge distance (Cracked concrete)cmin,s[mm]
40455570
REDUCED EMBEDMENT DEPTH
Min. hole depth in substrateh0,r[mm]
50597090
Min. installation depthhnom,r[mm]
401)491)6080
Min. substrate thicknesshmin,r[mm]
100100100130
Min. spacing (Uncracked concrete)smin,r[mm]
5070120150
Min. spacing (Cracked concrete)smin,r[mm]
5070120150
Min. edge distance (Uncracked concrete)cmin,r[mm]
50607090
Min. edge distance (Cracked concrete)cmin,r[mm]
40507085
1) Use restricted to anchoring statically indeterminate structural components
SizeM8M10M12M16
Nominal ultimate tensile strengthfuk[N/mm2]
700700650650
Nominal yield strengthfyk[N/mm2]
560560520520
Cross sectional area As[mm2]
25,540,760,1106,6
Elastic section modulusWel[mm3]
34,368,3119,6229,5
Characteristic bending resistanceM0Rk,s[Nm]
224572180
Design bending resistanceM[Nm]
173657144
SizeM8M10M12M16
Standard embedment depthhef[mm]
47596885
Reduced embedment depthhef[mm]
321)391)4865
MEAN ULTIMATE RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRu,m[kN]
15,422,829,255,8
Reduced embedment depthNRu,m[kN]
10,41622,137,9
CRACKED CONCRETE
Standard embedment depthNRu,m[kN]
9,711,518,630,4
Reduced embedment depthNRu,m[kN]
5,69,813,422,2
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRu,m[kN]
1422,229,654,5
Reduced embedment depthVRu,m[kN]
12,2219,7322,4554,5
CRACKED CONCRETE
Standard embedment depthVRu,m[kN]
12,8721,229,654,5
Reduced embedment depthVRu,m[kN]
8,613,8815,849,78
CHARACTERISTIC RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRk[kN]
9162538,55
Reduced embedment depthNRk[kN]
7,511,9816,3625,78
CRACKED CONCRETE
Standard embedment depthNRk[kN]
691225
Reduced embedment depthNRk[kN]
37,5916
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRk[kN]
11,718,524,645,4
Reduced embedment depthVRk[kN]
8,914,3816,3645,4
CRACKED CONCRETE
Standard embedment depthVRk[kN]
11,115,6124,645,4
Reduced embedment depthVRk[kN]
6,2310,0611,4536,09
DESIGN RESISTANCE
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNRd[kN]
510,6716,6725,7
Reduced embedment depthNRd[kN]
4,176,6610,9117,19
CRACKED CONCRETE
Standard embedment depthNRd[kN]
3,336816,67
Reduced embedment depthNRd[kN]
1,674,17610,67
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVRd[kN]
9,3614,819,6836,32
Reduced embedment depthVRd[kN]
5,949,5910,9134,37
CRACKED CONCRETE
Standard embedment depthVRd[kN]
7,410,419,6835,98
Reduced embedment depthVRd[kN]
4,166,717,6324,06
RECOMMENDED LOAD
TENSION LOAD
UNCRACKED CONCRETE
Standard embedment depthNrec[kN]
3,577,6211,918,36
Reduced embedment depthNrec[kN]
2,984,757,7912,28
CRACKED CONCRETE
Standard embedment depthNrec[kN]
2,384,295,7111,9
Reduced embedment depthNrec[kN]
1,192,984,297,62
SHEAR LOAD
UNCRACKED CONCRETE
Standard embedment depthVrec[kN]
6,6910,5714,0625,94
Reduced embedment depthVrec[kN]
4,246,857,7924,55
CRACKED CONCRETE
Standard embedment depthVrec[kN]
5,297,4314,0625,7
Reduced embedment depthVrec[kN]
2,974,795,4517,19
1) Use restricted to anchoring statically indeterminate structural components
SizeM8M10M12M16
Nominal embedment depthhnom[mm]
401)55491)6960708090
Effective embedment depthhef[mm]
321)47391)5948686585
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
21,221,233,633,644,844,882,682,6
Partial safety factorγMS[-]
1,51,51,51,51,51,51,51,5
PULL-OUT FAILURE
Characteristic resistance in uncracked concrete C20/25NRk,p,ucr[kN]
7,591216-25--
Characteristic resistance in cracked concrete C20/25NRk,p,cr[kN]
367,599121625
Installation safety factorγinst[-]
1,21,21,211111
Increasing factors for concrete C30/37Ψc[-]
1,071,161,071,261,161,231,181,18
Increasing factors for concrete C40/50Ψc[-]
1,131,331,131,521,321,451,371,37
Increasing factors for concrete C50/60Ψc[-]
1,21,51,21,781,491,671,551,55
CONCRETE CONE FAILURE
Installation safety factorγinst[-]
1,21,21,211111
Factor for uncracked concretekucr,N[-]
1111111111111111
Factor for cracked concretekcr,N[-]
7,77,77,77,77,77,77,77,7
Spacingscr,N[mm]
96141117177144204195255
Edge distanceccr,N[mm]
487159897210298128
CONCRETE SPLITTING FAILURE
Spacingscr,sp[mm]
160240200300250340320430
Edge distanceccr,sp[mm]
80120100150125170160215
Installation safety factorγinst[-]
1,21,21,211111
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armV0Rk,s[kN]
11,711,718,518,524,624,645,445,4
Ductility factork7[-]
0,80,80,80,80,80,80,80,8
Characteristic resistance with lever armMRk,s[Nm]
222245457272180180
Partial safety factorγMS[-]
1,251,251,251,251,251,251,251,25
CONCRETE PRY-OUT FAILURE
Factork[-]
111,211222
Installation safety factorγinst[-]
11111111
CONCRETE EDGE FAILURE
Effective length of anchorℓf[mm]
3247395948686585
Anchor diameterdnom[mm]
88101012121616
Installation safety factorγinst[-]
11111111
1) Use restricted to anchoring statically indeterminate structural components
(-) failure is not decisive
SizeM8M10M12M16
R (for EI) = 30 min
Effective embedment depthhef[mm]
321)47391)5948686585
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,70,71,51,52,52,54,74,7
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,81,51,92,32,3346,3
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,70,71,51,52,52,54,74,7
Characteristic resistance with lever armMRk,s[Nm]
0,70,71,91,93,93,91010
R (for EI) = 60 min
Effective embedment depthhef[mm]
321)47391)5948686585
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,60,61,21,22,12,13,93,9
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,81,51,92,32,3346,3
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,60,61,21,22,12,13,93,9
Characteristic resistance with lever armMRk,s[Nm]
0,60,61,51,53,33,38,38,3
R (for EI) = 90 min
Effective embedment depthhef[mm]
321)47391)5948686585
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,40,40,90,91,71,73,13,1
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,81,51,92,32,3346,3
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,40,40,90,91,71,73,13,1
Characteristic resistance with lever armMRk,s[Nm]
0,40,41,21,22,62,66,76,7
R (for EI) = 120 min
Effective embedment depthhef[mm]
321)47391)5948686585
TENSION LOAD
STEEL FAILURE
Characteristic resistanceNRk,s[kN]
0,40,40,80,81,31,32,52,5
PULL-OUT FAILURE
Characteristic resistanceNRk,s[kN]
0,61,21,51,81,82,43,25
SHEAR LOAD
STEEL FAILURE
Characteristic resistance without lever armVRk,s[kN]
0,40,40,80,81,31,32,52,5
Characteristic resistance with lever armMRk,s[Nm]
0,40,4112,12,15,35,3
1) Use restricted to anchoring statically indeterminate structural components
* In absence of other national regulations the partial safety factor for resistance under fire exposure. γM,fi = 1,0 is recommended
SizeM8M10M12M16
Effective embedment depthhef[mm]
321)47391)59481)68651)85
SEISMIC CATEGORY C1
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C1[kN]
21,221,233,633,644,844,882,682,6
Partial safety factorγMsN,seisC1[-]
1,51,51,51,51,51,51,51,5
TENSION LOAD, PULL-OUT FAILURE
Characteristic resistanceNRk,p,C1[kN]
367,599121625
Installation safety factorγinst[-]
1,21,21,211111
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C1[kN]
-6,7-12,518,418,43939
Partial safety factorγMsV,seisC1[-]
1,251,251,251,251,251,251,251,25
SEISMIC CATEGORY C2
TENSION LOAD, STEEL FAILURE
Characteristic resistanceNRk,s,C2[kN]
--33,633,644,844,8--
Partial safety factorγMsN,seisC2[-]
--1,51,51,51,5--
Characteristic resistanceNRk,p,C2[kN]
Characteristic resistanceNRk,p,C2[kN]
--2,6334,2--
Installation safety factorγinst[-]
--1,2111--
SHEAR LOAD, STEEL FAILURE
Characteristic resistance without lever armVRk,s,C2[kN]
---8,3-11,1--
Partial safety factorγMsV,seisC2[-]
--1,251,251,251,25--
1) Use restricted to anchoring statically indeterminate structural components
RozmiarS1
M8M10M12M16
diameter = 8diameter = 10diameter = 12diameter = 16
code:thread_diameter
code:hole_diameter_in_the_substrate
installation_torque
code: wrench_size
code:washer_external_diameter
STANDARDOWA GŁĘBOKOŚĆ ZAKOTWIENIAS2
minimum_depth_of_the_hole_in_the_substrate_standard
minimum_depth_of_the_connector_standard
[minimal_thickness_of_the_substrate_standard]
minimal_spacing_standard_noncracked_conrete
minimal_distance_from_the_edge_standard_noncracked_concrete
minimal_distance_from_the_edge_standard_cracked_concrete
ZREDUKOWANA GŁĘBOKOŚĆ ZAKOTWIENIAS2
minimum_depth_of_the_hole_in_the_substrate_reduced
minimum_depth_of_the_connector_reduced
minimal_thickness_of_the_substrate_reduced
minimal_spacing_reduced_noncracedcracked_conrete
minimal_spacing_reduced_cracked_conrete
minimal_distance_from_the_edge_reduced_cracked_concrete
minimal_distance_from_the_edge_reduced_noncracked_concrete
SizeProductKotwa / ŚrednicaKotwa / DługośćKotwa Element mocowany / Max grubość tfix dla
diameterlengthFIXTURE_MAX_THICKNESS_standard_embedment_depth
M8R-HPTIIA4-08060/10 | sku: PIM-R-HPTII-A4-8-60
M8R-HPTIIA4-08075/10 | sku: PIM-R-HPTII-A4-8-75
M8R-HPTIIA4-08085/20 | sku: PIM-R-HPTII-A4-8-85
M8R-HPTIIA4-08095/30 | sku: PIM-R-HPTII-A4-8-95
M8R-HPTIIA4-08105/40 | sku: PIM-R-HPTII-A4-8-105
M8R-HPTIIA4-08115/50 | sku: PIM-R-HPTII-A4-8-115
M10R-HPTIIA4-10065/5 | sku: PIM-R-HPTII-A4-10-65
M10R-HPTIIA4-10080/20 | sku: PIM-R-HPTII-A4-10-85
M10R-HPTIIA4-10095/15 | sku: PIM-R-HPTII-A4-10-95
M10R-HPTIIA4-10115/35 | sku: PIM-R-HPTII-A4-10-115
M10R-HPTIIA4-10130/50 | sku: PIM-R-HPTII-A4-10-130
M10R-HPTIIA4-10140/60 | sku: PIM-R-HPTII-A4-10-140
M12R-HPTIIA4-12080/5 | sku: PIM-R-HPTII-A4-12-80
M12R-HPTIIA4-12100/5 | sku: PIM-R-HPTII-A4-12-100
M12R-HPTIIA4-12115/20 | sku: PIM-R-HPTII-A4-12-115
M12R-HPTIIA4-12125/30 | sku: PIM-R-HPTII-A4-12-125
M12R-HPTIIA4-12150/55 | sku: PIM-R-HPTII-A4-12-150
M12R-HPTIIA4-12180/85 | sku: PIM-R-HPTII-A4-12-180
M16R-HPTIIA4-16125/5 | sku: PIM-R-HPTII-A4-16-125
M16R-HPTIIA4-16140/20 | sku: PIM-R-HPTII-A4-16-140
M16R-HPTIIA4-16150/30 | sku: PIM-R-HPTII-A4-16-150

Approvals and publications

Technical library

(6)

Technical assessments(2)

ETA-17/0185 (2021-12-16)

R-HPTII-A4 - Torque controlled expansion anchor for use in cracked and uncracked concrete.

UKTA-0836-22/6203 (2022-11-22)

R-HPTII-A4 - Torque controlled expansion anchor for use in cracked and uncracked concrete.

Declarations(2)

DoP-17/0185-R-HPTII-A4 - ETA 17/0185 (2021-12-16)

R-HPTII-A4 - Torque controlled expansion anchor for use in cracked and uncracked concrete.

UKTA-DoP-22/6203-R-HPTII-A4 - UKTA-0836-22/6203 (2022-11-22)

R-HPTII-A4 - Torque controlled expansion anchor for use in cracked and uncracked concrete.

Certificates(2)

1488-CPR-0628/W - ETA 17/0185 (2021-12-16)

R-HPTII-A4 - Torque controlled expansion anchor for use in cracked and uncracked concrete.

UK-0836-CPR-23/P6742 - UKTA-0836-22/6203 (2022-11-22)

R-HPTII-A4 - Torque controlled expansion anchor for use in cracked and uncracked concrete.

Catalogues and product cards

(4)

Product cards(1)

Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP