1. Mainpage
  2. R-TFIX-8S-X Setting tool TX40 for countersunk installation, plastic - cardboard box - 1 pc.

R-TFIX-8S-X Setting tool TX40 for countersunk installation, plastic - cardboard box - 1 pc.

Universal

R-TFIX-TOOL-CS

5906675421636

Rawlplug

TX40 Setting tool with integrated disc and perforator for countersunk installation of screw-in fixing R-TFIX-8SX

Define product parameters:

Packaging and quantity
Weight and bulk packaging
  • Unit pack

    1.00 pcs.0.20 kg

  • Bulk pack

    12.00 pcs.2.83 kg

  • Pallet

    288.00 pcs.67.92 kg

Related products

Insulation retaining plate R-KWL 140 mm, polyamide - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

Rawlplug SDS Plus Rebar Drill Bit 8.0 x 150 x 210mm, PGM Approved - plastic hanger - 1 pc.

High-quality SDS plus drill bits for drilling in reinforced concrete

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x235 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x195 mm - cardboard box - 200 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

R-TFIX-CAP Polystyrene cap EPS 63x10 mm, white - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

R-TFIX CAP For Mineral Wool, 63/10 Brown - cardboard box - 100 pcs.

Post-installed cap reduces heat transmission and results in a homogenous insulation surface

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x255 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Insulation retaining plate R-KWL 90 mm, polyamide - cardboard box - 200 pcs.

Insulation retaining plate for use in combination with facade fixings from TFIX and KI ranges

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x215 mm - cardboard box - 100 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Universal screw-in facade fixings without plastic overmoulded screw R-TFIX-8S-X 8x175 mm - cardboard box - 200 pcs.

The most effective screw-in facade fixing for countersunk installation with the possibility of surface mounting

Brickdrill SDS PLUS non-impact drill bits 8.0x260 m - plastic hanger - 1 pc.

Drill bits for non-impact drilling in ceramic materials

Aggressor SDS Plus drill bits 8x150x210 mm - plastic hanger - 1 pc.

Drill bits SDS plus for fast drilling in concrete

Features

TX40 Setting tool with integrated disc and perforator for countersunk installation of screw-in fixing R-TFIX-8SX

  • Ideal design of TX40 bit perfect suited to the screw-in R-TFIX-8S-X allows easy and stable installation.
  • Torx-40 bit type.
  • Countersunk installation (with post-installed insulation cap) reduces heat transmission and results in a homogenous insulation surface.
  • Integrated disc and perforator facilitates optimum R-TFIX-8SX countersunk installation, for the perfect flush with the surface of the insulation it is necessery to use additional insulation cap R-TFIX-CAP63.
  • User-friendly - enables fast installation.

Substrates

Mineral wool boards

Mineral wool boards

Polystyrene (EPS) boards

Polystyrene (EPS) boards

Approved surfaces

Applications

Facades - thermal insulation systems

Full list of variations

Type of package
Piece. per pack.
Index
EAN

Cardboard box

1R-TFIX-TOOL-CS5906675421636

Contact with us and check out our terms of cooperation

Substitutes

Services

Design Consulting

Design Consulting

Training at the Rawlplug Academy center

Training at the Rawlplug Academy center

Technical Support 2

Technical Support 2

Rawlplug Academy

Rawlplug Academy

Installation guide

Installation manual

Installation step by step

1

Drill a hole to the required diameter and depth for rebar size being used.

2

Clean drilled hole 3 times.

3

Insert R-TFIX-TOOL-CS into recess in head moulding of R-TFIX-8S-X screw.

4

Tighten the plug screw until the appropriate embedding depth is reached (the plate should be on the surface with a thermal insulation layer).

5

After setting the pin in the hole, the plate should be pressed against the thermal insulation surface.

6

After fixing the connector, close the hole with a mineral wool plug.

7

R-TFIX-8SX pin is properly installed.

Installation data

Approvals and publications

Catalogues and product cards

(1)

Product cards(1)

Product cart

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2025 Koelner Rawlplug IP