  7. Galvanized sleeve anchor for low loads KT M10x50 mm - cardboard box - 50 pcs.

Galvanized sleeve anchor for low loads KT M10x50 mm - cardboard box - 50 pcs.

Solid walls

KT-10050

5906675021225

Koelner

Universal anchor for medium loads in non-cracked concrete

Define product parameters:

Metric diameter
Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    50.00 pcs.1.64 kg

  • Bulk pack

    50.00 pcs.1.64 kg

  • Pallet

    9600.00 pcs.256.50 kg

Features

Universal anchor for medium loads in non-cracked concrete

  • Suitable for temporary fixings.
  • Low weight mechanical sleeve anchor.
  • Product approved AT option 7.

Substrates

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Reinforced concrete

Reinforced concrete

Unreinforced concrete

Unreinforced concrete

Approved surfaces

Applications

Doors and windows

Radiators

Satellite dishes

Poles and road signs

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Place the drill bit in the hole.

2

Blow out the dust at least 4 times with the hand pump.

3

Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached.

4

Tighten to the recommended torque.

5

The anchor is correctly fixed.

Design data
SizeM6M8M10M12M16
Thread diameterd[mm]
68101216
Hole diameter in substrated0[mm]
810121620
Installation torqueTinst[Nm]
123570120200
Min. hole depth in substrateh0[mm]
4050606070
Min. installation depthhnom[mm]
3540505560
Min. substrate thicknesshmin[mm]
7080100110120
Min. spacingsmin[mm]
105120150165180
Edge distanceccr,N[mm]
5560758590
SizeM6M8M10M12M16
Nominal ultimate tensile strengthfuk[N/mm2]
500500500500500
Nominal yield strengthfyk[N/mm2]
400400400400400
Cross sectional area As[mm2]
20.136.65884.3157
Elastic section modulusWel[mm3]
21.2150.2798.17169.56402.12
Characteristic bending resistanceM0Rk,s[Nm]
12.7230.1658.9101.79241.27
Design bending resistanceM[Nm]
10.1824.1347.1281.43193.02
SizeM6M8M10M12M16
Effective embedment depthhef[mm]
35.0040.0050.0055.0060.00
CHARACTERISTIC LOAD
Tension loadNRk[kN]
6.006.0019.0027.0031.00
Shear loadVRk[kN]
6.006.0019.0027.0031.00
DESIGN LOAD
Tension loadNRd[kN]
2.852.859.0412.8514.76
Shear loadVRd[kN]
4.804.8015.2021.6024.80
SizeM6M8M10M12M16
Effective embedment depthhef[mm]
35.0040.0050.0055.0060.00
TENSION LOAD
NON-CRACKED CONCRETE C20/25
Characteristic loadNRk[kN]
6.006.0019.0027.0031.00
Installation safety factorγinst[-]
1.401.401.401.401.40
Increasing factors for concrete C30/37Ψc[-]
1.221.221.221.221.22
Increasing factors for concrete C40/50Ψc[-]
1.411.411.411.411.41
Increasing factors for concrete C50/60Ψc[-]
1.551.551.551.551.55
Characteristic loadNRk[kN]
5.005.50---
Installation safety factorγinst[-]
1.661.66---
SHEAR LOAD
NON-CRACKED CONCRETE C20/25
Characteristic loadVRk[kN]
6.006.0019.0027.0031.00
Installation safety factorγinst[-]
1.251.251.251.251.25
Characteristic loadVRk[kN]
5.005.50---
Installation safety factorγinst[-]
1.251.25---

Approvals and publications

Technical library

(3)

Technical assessments(1)

ITB_KOT_2018_0161_wyd2_1_

Declarations(1)

KDWU_2018_0161_2_KT

Certificates(1)

020_UWB_3033_W_KT

Catalogues and product cards

(2)

Product cards(1)

Product cart

Catalogues(1)

Catalogue

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP