1. Mainpage
  2. Products
  3. Anchors
  4. Mechanical anchors
  5. Wedge anchors
  6. R-DCA Drop-In Anchor M16 x 65mm - cardboard box - 25 pcs.

R-DCA Drop-In Anchor M16 x 65mm - cardboard box - 25 pcs.

Solid walls

R-DCA-16-65

5010445771507

RawlplugRawl

Internally threaded zinc plated wedge anchor

Define product parameters:

Metric diameter
Packaging and quantity
Length
Coating
Weight and bulk packaging
  • Unit pack

    25.00 pcs.2.80 kg

  • Bulk pack

    200.00 pcs.22.40 kg

  • Pallet

    8400.00 pcs.965.80 kg

Features

Internally threaded zinc plated wedge anchor

  • Product is covered with European Technical Assessment for multi-point non-structural fixings.
  • Easy to install by hammer action and manual setting tool.
  • Product was tested for construction fixing.
  • High performance in cracked and non-cracked concrete confirmed by ETA.
  • Product recommended for applications requiring fire resistance.
  • Internally threaded to be used with threaded stud or bolt.
  • Slotted sleeve and internal wedge component together facilitate easy setting and expansion.

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Unreinforced concrete

Unreinforced concrete

Reinforced concrete

Reinforced concrete

Approved surfaces

Applications

Air conditioning / ventilation

Electrical Installations

Pipelines

Sprinkler installations

Steel structures

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill the hole and clean it up.

2

Blow out dust at least 4 times with a hand pump.

3

Insert the anchor into the hole and hammer it in until it is flush with the substrate.

4

By striking the special hammer with the hammer, expand the anchor in the hole.

5

Place the element to be fastened, insert the screw or threaded rod and tighten to the required torque.

Installation data
Design data
SizeM6/25M8/30M10/40M12/50M16/65M20/80
Thread diameterd[mm]
6810121620
Hole diameter in substrated0[mm]
81012152025
Hole diameter in fixturedf[mm]
7912141822
Max. installation torqueTinst[Nm]
4,511223898130
Internal thread lengthlg[mm]
111419252838
Min. hole depth in substrateh0[mm]
273242526782
Min. installation depthhnom[mm]
253040506580
Min. substrate thicknesshmin[mm]
808080100130160
Min. spacingsmin[mm]
200200200200260320
Min. edge distancecmin[mm]
150150150150185240
SizeM6/25M8/30M10/40M12/50M16/65M20/80
R-STUDS Metric Threaded Rods - Steel Class 4.8
Nominal ultimate tensile strengthfuk[N/mm2]
450450450450450450
Nominal yield strengthfyk[N/mm2]
360360360360360360
Cross sectional area As[mm2]
20,136,65884,3156,7244,8
Elastic section modulusWel[mm3]
21,231,262,3109,1276,6540,2
Characteristic bending resistanceM0Rk,s[Nm]
6153052133260
Design bending resistanceM[Nm]
4,8122441,6106,4208
SizeM6/25M8/30M10/40M12/50M16/65M20/80
Nominal embedment depthhnom[mm]
253040506580
CHARACTERISTIC LOAD
TENSION AND SHEAR LOAD FRk
Uncracked and cracked concrete C12/15-[kN]
1,223,551013
Uncracked and cracked concrete C20/25 - C50/60-[kN]
1,534,561317
DESIGN LOAD
TENSION AND SHEAR LOAD FRd
Uncracked and cracked concrete C12/15-[kN]
0,671,111,942,785,567,22
Uncracked and cracked concrete C20/25 - C50/60-[kN]
0,831,672,53,337,229,44
RECOMMENDED LOAD
TENSION AND SHEAR LOAD Frec
Uncracked and cracked concrete C12/15-[kN]
0,480,791,391,983,975,16
Uncracked and cracked concrete C20/25 - C50/60-[kN]
0,61,191,792,385,166,75
SizeM6/25M8/30M10/40M12/50M16/65M20/80
Effective embedment depthhef[mm]
253040506580
TENSION AND SHEAR LOAD
CRACKED AND UNCRACKED CONCRETE
Characteristic resistance - concrete C12/15F0Rk[kN]
1,223,551013
Characteristic resistance - concrete C20/25 - C50/60F0Rk[kN]
1,534,561317
Installation safety factorγinst[-]
1,21,21,21,21,21,2
Spacingscr[mm]
200200200200260320
Edge distanceccr[mm]
150150150150195240
Characteristic resistance with lever arm (Steel class 4.8)M0Rk,s[Nm]
6153052133260
Characteristic resistance with lever arm (Steel class 5.8)M0Rk,s[Nm]
8193766167325
Characteristic resistance with lever arm (Steel class 6.8)M0Rk,s[Nm]
9234579200390
Characteristic resistance with lever arm (Steel class 8.8)M0Rk,s[Nm]
123060105267520
Partial safety factorγMS[-]
1,251,251,251,251,251,25
SizeM6/25M8/30M10/40M12/50M16/65M20/80
Effective embedment depthhef[mm]
253040506580
Edge distance 1)ccr,fi[mm]
506080100130160
Spacingscr,fi[mm]
100120160200260320
TENSION AND SHEAR LOAD
R (for EI) = 30 min
Characteristic resistanceNRk,fi[kN]
-0,40,91,63,14,3
R (for EI) = 60 min
Characteristic resistanceNRk,fi[kN]
-0,30,81,32,43,7
R (for EI) = 90 min
Characteristic resistanceNRk,fi[kN]
-0,30,61,123,2
R (for EI) = 120 min
Characteristic resistanceNRk,fi[kN]
-0,20,50,81,62,5
1) In case of fire attack from more than one side, the edge distance shall be ≥ 300 mm

Approvals and publications

Technical library

(8)

Technical assessments(3)

ETA-13/0584

Fasteners for use in concrete for redundant non-structural applications

KOT-2017/0165

ITB-KOT-2017/0165w3

UKTA-22/6371

UKTA-22/6371

Declarations(3)

DoP-13/0584-R-DCA

KDWU-2017-0165-R-DCA

UKTA-DoP-22/6371-R-DCA

Certificates(2)

1488-CPR-0328/Z

CPR

020_UWB_2994_W

020-UWB-2994/W

Catalogues and product cards

(4)

Product cards(1)

Product card

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP