  6. Metal insulation fixing R-MBA 8x250 mm - cardboard box - 125 pcs.

Metal insulation fixing R-MBA 8x250 mm - cardboard box - 125 pcs.

Universal

R-MBA-08250

5906675521985

Fire-resistant metal insulation fixing

Define product parameters:

Length
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    125.00 pcs.5.00 kg

  • Bulk pack

    125.00 pcs.5.00 kg

  • Pallet

    6750.00 pcs.270.00 kg

Features

Fire-resistant metal insulation fixing

  • Metal facade fixing, recommended for use when fire resistance (F120) is a requirement.
  • Fast and simple hammer-set installation reduces working times.
  • Accessory spreader plate, MKC-SS (85mm diameter) also available for installation of soft insulation materials such as mineral wool.
  • Extensive dimensional range allows anchorage of insulation boards up to 250mm thick.
  • Made of galvanized steel, resistant to damage and corrosion.
  • For countersunk installation, we recommend using the R-KFS-90/20 cutter and the R-TFIX-CAP90-MW mineral wool cup.

Product video

R_MBA_monta_zag__bionywwe_niemineralnej

R_MBA_monta_powierzchniowywwe_niemineralnej

Krok_po_kroku_jak_montowac_metalowe_kolki_fasadowe

Substrates

Concrete C20/25-C50/60 (A)

Concrete C20/25-C50/60 (A)

Solid brick (B)

Solid brick (B)

Solid sand-lime brick (B)

Solid sand-lime brick (B)

Ceramic hollow block

Ceramic hollow block

Hollow sand-lime brick ≥ 15MPa

Hollow sand-lime brick ≥ 15MPa

Aerated concrete

Aerated concrete

Approved surfaces

Applications

Facades - thermal insulation systems

Full list of variations

Substitutes

Expert advice

Services

Installation guide

Installation manual

Installation step by step

1

Drill hole to the required diameter and depth for rebar size being usee

2

Blow out dust at least 3 times with a hand pump.

3

Gently drive the steel dowel into the hole until the correct anchorage depth for the fastener is achieved. For soft substrates, use the MKC 85 mm steel washer.

4

Correctly installed steel facade fixing.

5

Cut the hole in insulation board.

6

Drill a hole of appropriate diameter and depth.

7

Clean drilled hole 3 times.

8

Gently drive the steel dowel into the hole until the correct anchorage depth for the fastener is achieved. For soft substrates, use the MKC 85 mm steel washer.

9

Insert cap into countersunk hole in insulation board following installation of the facade fixing.

10

Correctly installed steel facade fixing.

Installation data
Design data
Use categoryA, BCE
Hole diameter in substrated0[mm]
88-
Min. installation depth hnom[mm]
305050
Min. substrate thicknesshmin[mm]
808080
Min. hole depth in substrateh0[mm]
4060 1) / 40 2)-
Min. edge distancecmin[mm]
757575
Min. spacingsmin[mm]
757575
1) Installation in hollow clay brick
2) Installation in silicate hollow brick
SKUmaterialfixing_diameter_d_mmfixing_length_L_mmfixing_plate_diameter_D_mmfastened_element_max_thicknessZP - galvanized8903540
ZP - galvanized81103560
ZP - galvanized81403590
ZP - galvanized817035120
ZP - galvanized820035150
ZP - galvanized821035160
ZP - galvanized823035180
ZP - galvanized825035200
ZP - galvanized830035250
Fixing typeR-MBA
Embedment depthhef[mm]
30 3)/50 4)
CHARACTERISTIC LOAD
TENSION LOAD
Concrete C20/25 - C50/60 (A) 1)NRk[kN]
0,9
Solid clay bricks min. 20MPa (B) 1)NRk[kN]
0,5
Solid sand-lime bricks min. 20MPa (B) 1)NRk[kN]
0,6
Perforated clay bricks min. 15MPa (C) 2)NRk[kN]
0,25
Hollow sand-lime blocks KS 301 min. 15MPa (C) 2)NRk[kN]
0,4
Autoclaved aerated concrete AAC5 min. 6MPa (E) NRk[kN]
0,8
DESIGN LOAD
TENSION LOAD
Concrete C20/25 - C50/60 (A) 1)NRd[kN]
0,36
Solid clay bricks min. 20MPa (B) 1)NRd[kN]
0,2
Solid sand-lime bricks min. 20MPa (B) 1)NRd[kN]
0,24
Perforated clay bricks min. 15MPa (C) 2)NRd[kN]
0,1
Hollow sand-lime blocks KS 301 min. 15MPa (C) 2)NRd[kN]
0,16
Autoclaved aerated concrete AAC5 min. 6MPa (E) NRd[kN]
0,4
RECOMMENDED LOAD
TENSION LOAD
Concrete C20/25 - C50/60 (A) 1)Nrec[kN]
0,3
Solid clay bricks min. 20MPa (B) 1)Nrec[kN]
0,1
Solid sand-lime bricks min. 20MPa (B) 1)Nrec[kN]
0,2
Perforated clay bricks min. 15MPa (C) 2)Nrec[kN]
0,1
Hollow sand-lime blocks KS 301 min. 15MPa (C) 2)Nrec[kN]
0,1
Autoclaved aerated concrete AAC5 min. 6MPa (E) Nrec[kN]
0,3
1) Hammer drilling
2) Rotary drilling only
3) Use category A, B
4) Use category C, E
Fixing typeR-MBA
Embedment depthhef[mm]
30
Edge distance R30 ÷ R120 1)ccr,fi[kN]
60
Spacing R30 ÷ R120scr,fi[kN]
120
TENSION LOAD
R (for EI) = 30 min
Characteristic resistanceNRk,fi[kN]
0,23
R (for EI) = 60 min
Characteristic resistanceNRk,fi[kN]
0,23
R (for EI) = 90 min
Characteristic resistanceNRk,fi[kN]
0,23
R (for EI) = 120 min
Characteristic resistanceNRk,fi[kN]
0,18
1) In case of fire attack from more than one side, the edge distance shall be ≥ 300 mm
2) Partial safety factor γM,fi = 1,0

Approvals and publications

Technical library

(3)

Technical assessments(1)

KOT_RAWLPLUG_MBA_R_MBA

ITB-KOT-2018/0721w6

Declarations(1)

KDWU_2018_0721_6_MBA_FACADE_FIXINGS_PL_1_

KDWU-2018-0721-R-MBA

Certificates(1)

020_UWB_0702Z_PL_

020-UWB-0702/Z

Catalogues and product cards

(4)

Product cards(1)

Technical card R-MBA

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP