1. Mainpage
  2. Products
  3. Anchors
  4. Chemical resin fixings
  5. Resin anchors for concrete
  6. Epoxy bonded anchor R-KEX-II 3:1 - plastic cartouche - 385 ml

Epoxy bonded anchor R-KEX-II 3:1 - plastic cartouche - 385 ml

Solid walls

R-KEX-II-385

5906675028538

High-quality bonded anchor based on epoxy resin, approved for cracked concrete, as well as reinforced and unreinforced concrete

Define product parameters:

Bonded anchors version
Packaging and quantity
Weight and bulk packaging
  • Unit pack

    10.00 pcs.6.71 kg

  • Bulk pack

    10.00 pcs.6.71 kg

  • Pallet

    560.00 pcs.389.00 kg

Features

High-quality bonded anchor based on epoxy resin, approved for cracked concrete, as well as reinforced and unreinforced concrete

  • Approved for use with post-installed rebars concrete (EAD 330087-01-0601).
  • Approved for use in non-cracked concrete (EAD 330499-02-0601), working life up to 100 years.
  • Seismic approval for categories C1 and C2.
  • The extended open time allows bar insertion to the required depth even at high temperatures. The short curing time enables continuation of work on the same day.
  • Extended working time ensures easy installation.
  • Suitable for use in dry and wet substrates including under water.
  • High parameter stability at elevated temperatures.

Product video

rawlplug_rkexii_pure_e

Montaz_kotwy_chemicznej_obciazanie_ukladu

Czymjestkotwachemicznaijakjeju_ywa__

Rawlplug_Academy_jaki_otwor_pod_kotwe_chemiczna

Rawlplug_Academy_jak_wyczyscic_otwor_pod_kotwe_chemiczna

RKEM_II_Zapowiedz_jak_zamontowac_bojler_za_pomoca_kotwy_chemicznej

Rawlplug_Academy_bledy_montazu_kotwy_chemicznej

R_KEM_II_jak_zamontowa_bojler

Jak_kotw_chemiczn_wybra__

Jakprawid_owou_y_kotwychemicznej_

Substrates

Cracked concrete C20/25-C50/60

Cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Non-cracked concrete C20/25-C50/60

Reinforced concrete

Reinforced concrete

Unreinforced concrete

Unreinforced concrete

High-density natural stone

High-density natural stone

Approved surfaces

Applications

Anchoring glued in with reinforcing bars

Anchoring glued in with threaded rods

Concrete structures

Elevators and escalators

Roads and bridges

Steel structures

Full list of variations

Substitutes

Services

Installation guide

Installation manual

Installation step by step

1

Drill a hole of appropriate diameter and depth.

2

Blow out the dust at least 4 times with the hand pump.

3

Remove drill cuttings in the hole using the brush four times.

4

Blow out the dust at least 4 times with the hand pump.

5

Insert cartridge into the gun and attach the nozzle.

6

​When beginning dispensing from a new cartouche, discard approximately 10 cm of resin to ensure thorough mixing of the components.

7

Fill the hole 70% with resin (follow the assembly instructions specific to the type of resin).

8

Immediately insert the rebar, slowly and with slight twisting motion. Remove any excess resin around the hole before it sets and leave it undisturbed until the curing time elapses.

9

Leave the anchor undisturbed unitl the curing time elapses.

10

Tighten to the recommended torque.

Design data
SizeM8M10M12M16M20M24M30
Thread diameterd[mm]
8101216202430
Hole diameter in substrated0[mm]
10121418242835
Hole diameter in fixturedf[mm]
9121418222633
Min. installation depthhnom,min[mm]
607080100120140165
Min. installation depthhnom,max[mm]
160200240320400480600
Min. hole depth in substrateh0[mm]
hnom + 5hnom + 5hnom + 5hnom + 5hnom + 5hnom + 5hnom + 5
Min. substrate thicknesshmin[mm]
hnom + 30 ≥
100
hnom + 30 ≥
100
hnom + 30 ≥
100
hnom + 2d0hnom + 2d0hnom + 2d0hnom + 2d0
Installation torqueTinst[Nm]
10204080120180200
Min. spacingsmin[mm]
40404050607085
Min. edge distancecmin[mm]
40404050607085
Concrete temperature [°C]+5+10+20+30
Max. processing time-[min]
1501203512
Min. curing time [min]
28801080480300
SizeM8M10M12M16M20M24M30
R-STUDS Metric Threaded Rods - Steel Class 5.8
Nominal ultimate tensile strengthfuk[N/mm2]
500500500500500500500
Nominal yield strengthfyk[N/mm2]
400400400400400400400
Cross sectional area As[mm2]
36,65884,3157245352,8559,8
Elastic section modulusWel[mm3]
31,262,3109,2277,55419351868
Characteristic bending resistanceM0Rk,s[Nm]
1937651663245611124
Design bending resistanceM[Nm]
153052133259449899
Allowable bending resistanceMrec[Nm]
11213795185321642
R-STUDS Metric Threaded Rods - Steel Class 8.8
Nominal ultimate tensile strengthfuk[N/mm2]
800800800800800800800
Nominal yield strengthfyk[N/mm2]
640640640640640640640
Cross sectional area As[mm2]
36,65884,3157245352,8559,8
Elastic section modulusWel[mm3]
31,262,3109,2277,55419351868
Characteristic bending resistanceM0Rk,s[Nm]
30601052665198981799
Design bending resistanceM[Nm]
2448842134167181439
Allowable bending resistanceMrec[Nm]
1734601522975131028
R-STUDS Metric Threaded Rods - Steel Grade A4
Nominal ultimate tensile strengthfuk[N/mm2]
700700700700700700700
Nominal yield strengthfyk[N/mm2]
450450450450450450450
Cross sectional area As[mm2]
36,65884,3157245352,8559,8
Elastic section modulusWel[mm3]
31,262,3109,2277,55419351868
Characteristic bending resistanceM0Rk,s[Nm]
2652922334547861574
Design bending resistanceM[Nm]
1734591492915041009
Allowable bending resistanceMrec[Nm]
122442107208360721
SizeM8M10M12M16M20M24M30
UNCRACKED CONCRETE C20/25
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
18,9030,4544,1067,5088,73111,81143,06
Maximum embedment depth-[kN]
18,9030,4544,1081,90128,10184,80294,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
28,6539,5348,3367,5088,73111,81143,06
Maximum embedment depth-[kN]
30,4548,3070,35132,30205,80296,10471,05
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
27,3039,5348,3067,0588,73111,81143,06
Maximum embedment depth-[kN]
27,3043,0561,95115,50179,55259,35412,65
SHEAR LOAD VRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
Maximum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
18,2728,9842,2179,38123,48177,66282,87
Maximum embedment depth-[kN]
18,2728,9842,2179,38123,48177,66282,87
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
16,3816,3837,1769,30107,73155,61247,59
Maximum embedment depth-[kN]
16,3816,3837,1769,30107,73155,61247,59
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
18,0028,8135,2049,1964,6781,49104,26
Maximum embedment depth-[kN]
18,0029,0042,0078,00122,00176,00280,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
22,8628,8135,2049,1964,6781,49104,26
Maximum embedment depth-[kN]
29,0046,0067,00126,00196,00282,00449,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
22,8628,8135,2049,1964,6781,49104,26
Maximum embedment depth-[kN]
26,0041,0059,00110,00171,00247,00393,00
SHEAR LOAD VRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00140,00
Maximum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00140,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,0023,0034,0063,0098,00141,00208,53
Maximum embedment depth-[kN]
15,0023,0034,0063,0098,00141,00224,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
13,0020,0029,0055,0086,00124,00196,00
Maximum embedment depth-[kN]
13,0020,0029,0055,0086,00124,00196,00
DESIGN RESISTANCE
TENSION LOAD NRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
12,0019,2123,4732,8043,1154,3369,51
Maximum embedment depth-[kN]
12,0019,3328,0052,0081,33117,33186,67
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,2419,2123,4732,8043,1154,3369,51
Maximum embedment depth-[kN]
19,3330,6744,6784,00130,67188,00299,33
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
13,9019,2123,4732,8043,1154,3369,51
Maximum embedment depth-[kN]
13,9021,9331,5558,8291,44132,09210,16
SHEAR LOAD VRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
7,2011,2016,8031,2048,8070,40112,00
Maximum embedment depth-[kN]
7,2011,2016,8031,2048,8070,40112,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
12,0018,4027,2050,4078,40108,65139,02
Maximum embedment depth-[kN]
12,0018,4027,2050,4078,40112,80179,20
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
8,3312,8218,5935,2655,1379,49125,64
Maximum embedment depth-[kN]
8,3312,8218,5935,2655,1379,49125,64
RECOMMENDED LOAD
TENSION LOAD Nrec
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
8,5713,7216,6723,4330,7938,8049,65
Maximum embedment depth-[kN]
8,5713,8120,0037,1458,1083,81133,33
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
8,5713,7216,6723,4330,7938,8049,65
Maximum embedment depth-[kN]
13,8121,9031,9060,0093,33134,29213,81
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
9,9313,7216,7623,4330,7938,8049,65
Maximum embedment depth-[kN]
9,9315,6622,5442,0265,3294,35150,11
SHEAR LOAD Vrec
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
5,148,0012,0022,2934,8650,2980,00
Maximum embedment depth-[kN]
5,148,0012,0022,2934,8650,2980,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
8,5713,1419,4336,0056,0077,6199,30
Maximum embedment depth-[kN]
8,5713,1419,4336,0056,0080,57128,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
5,959,1613,2825,1839,3856,7889,74
Maximum embedment depth-[kN]
5,959,1613,2825,1839,3856,7889,74
SizeM8M10M12M16M20M24M30
CRACKED CONCRETE C20/25
MEAN ULTIMATE RESISTANCE
TENSION LOAD NRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
18,9027,8233,9947,5062,4476,68100,67
Maximum embedment depth-[kN]
18,9030,4544,1081,90128,10184,80294,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
22,0827,8233,9947,5062,4476,68100,67
Maximum embedment depth-[kN]
30,4548,3070,35132,30205,80196,10471,45
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
22,0827,8233,9947,5062,4476,68100,67
Maximum embedment depth-[kN]
27,3043,0561,95115,50179,55259,35412,65
SHEAR LOAD VRu,m
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
Maximum embedment depth-[kN]
11,3418,2726,4649,1476,86110,88176,40
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
18,2728,9842,2179,38123,48153,37201,35
Maximum embedment depth-[kN]
18,2728,9842,2179,38123,48177,66282,87
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
16,3825,8331,1769,30107,73155,61201,35
Maximum embedment depth-[kN]
16,3825,8331,1769,30107,73155,6147,59
CHARACTERISTIC RESISTANCE
TENSION LOAD NRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
12,0617,5921,1134,4445,2757,0472,98
Maximum embedment depth-[kN]
18,0029,0042,0078,00122,00176,00280,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
12,0617,5921,1134,4445,2757,0472,98
Maximum embedment depth-[kN]
29,0046,0063,33112,59175,93217,15282,74
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
12,0617,5921,1134,4445,2757,0472,98
Maximum embedment depth-[kN]
26,0041,0059,00110,00171,00217,15282,74
SHEAR LOAD VRk
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00140,00
Maximum embedment depth-[kN]
9,0014,0021,0039,0061,0088,00140,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
15,0023,0034,0063,0090,53114,08145,98
Maximum embedment depth-[kN]
15,0023,0034,0063,0090,53114,08224,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
13,0020,0029,0055,0086,00114,08145,98
Maximum embedment depth-[kN]
13,0020,0029,0055,0086,00124,0196,0
DESIGN RESISTANCE
TENSION LOAD NRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
8,0411,7314,0722,9630,1838,0348,66
Maximum embedment depth-[kN]
12,0019,3328,0052,0081,33117,33186,67
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
8,0411,7314,0722,9630,1838,0348,66
Maximum embedment depth-[kN]
19,3330,6742,2275,06117,29144,76188,50
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
8,0411,73,14,0722,9630,1838,0348,66
Maximum embedment depth-[kN]
13,9021,9331,5558,8291,44132,09188,50
SHEAR LOAD VRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
7,2011,2016,8031,2048,8070,4097,31
Maximum embedment depth-[kN]
7,2011,2016,8031,2048,8070,40112,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
12,0018,4027,2045,9160,3676,0697,31
Maximum embedment depth-[kN]
12,0018,4027,2050,4078,40112,80179,20
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
8,3312,8218,5935,2655,1376,0697,31
Maximum embedment depth-[kN]
8,3312,8218,5935,2655,1379,49125,64
RECOMMENDED LOAD
TENSION LOAD NRd
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
5,748,3810,0516,4021,5627,1634,75
Maximum embedment depth-[kN]
8,5713,8120,0037,1458,1083,81133,33
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
5,748,3810,0516,4021,5627,1634,75
Maximum embedment depth-[kN]
13,8121,9030,1655,6283,78103,40134,64
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
5,748,3810,0516,4021,5627,1634,75
Maximum embedment depth-[kN]
9,9315,6622,5442,0265,3294,35134,64
SHEAR LOAD Vrec
R-STUDS Metric Threaded Rods - Steel Class 5.8
Minimum embedment depth-[kN]
5,148,0012,0022,2934,8650,2969,51
Maximum embedment depth-[kN]
5,148,0012,0022,2934,8650,2980,00
R-STUDS Metric Threaded Rods - Steel Class 8.8
Minimum embedment depth-[kN]
8,5713,1419,4332,8043,1154,3369,51
Maximum embedment depth-[kN]
8,5713,1419,4336,0056,0080,57128,00
R-STUDS Metric Threaded Rods - Steel Grade A4
Minimum embedment depth-[kN]
5,959,1613,2825,1839,3854,3369,51
Maximum embedment depth-[kN]
5,959,1613,2825,1839,3854,3389,74
SizeM8M10M12M16M20M24M30
TENSION LOAD
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistanceNRk,s[kN]
18,0029,0042,0078,00122,00176,00280,00
Partial safety factorγMS[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistanceNRk,s[kN]
29,0046,0067,00126,00196,00282,00448,00
Partial safety factorγMS[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistanceNRk,s[kN]
26,0041,0059,00110,00171,00247,00392,00
Partial safety factorγMS[-]
1,871,871,871,871,871,871,87
WORKING LIFE 50 YEARS
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; UNCRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
17,0016,0017,0015,0015,0013,0012,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
15,0014,0015,0013,0013,0012,0010,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; UNCRACKED CONCRETE C20/25 - DIAMOND DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
14,0015,0016,0014,0014,0012,0011,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
12,0014,0014,0013,0013,0011,0010,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; CRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
8,008,007,007,007,006,005,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
7,007,006,006,006,005,004,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; CRACKED CONCRETE C20/25 - DIAMOND DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
5,507,008,007,008,007,004,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
5,006,507,506,507,006,503,50
FACTORS
Factor of the influence of sustained load (40°C/24°C)Ψ0sus[-]
0,750,750,750,750,750,750,75
Factor of the influence of sustained load (80°C/50°C)Ψ0sus[-]
0,720,720,720,720,720,720,72
WORKING LIFE 100 YEARS
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; UNCRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
17,0016,0017,0015,0015,0013,0012,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
15,0014,0015,0013,0013,0012,0010,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; UNCRACKED CONCRETE C20/25 - DIAMOND DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
14,0015,0016,0014,0014,0012,0011,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
12,0014,0014,0013,0013,0011,0010,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; CRACKED CONCRETE C20/25 - HAMMER DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
8,008,006,507,007,006,005,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
6,507,006,006,006,005,004,00
COMBINED PULL-OUT AND CONCRETE CONE FAILURE; CRACKED CONCRETE C20/25 - DIAMOND DRILLING
Characteristic bond resistance (40°C/24°C)τRk[N/mm2]
5,507,008,007,007,006,004,00
Characteristic bond resistance (80°C/50°C)τRk[N/mm2]
5,006,507,006,006,505,003,50
FACTORS
Factor of the influence of sustained load (40°C/24°C)Ψ0sus[-]
0,600,600,600,600,600,600,60
Factor of the influence of sustained load (80°C/50°C)Ψ0sus[-]
0,600,600,600,600,600,600,60
COMBINED PULL-OUT AND CONCRETE CONE FAILURE
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
Increasing factors for concrete C30/37Ψc[-]
1,041,041,041,041,041,041,04
Increasing factors for concrete C40/50Ψc[-]
1,071,071,071,071,071,071,07
Increasing factors for concrete C50/60Ψc[-]
1,091,091,091,091,091,091,09
CONCRETE CONE FAILURE
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
Factor for cracked concretekcr,N[-]
7,707,707,707,707,707,707,70
Factor for uncracked concretekucr,N[-]
11,0011,0011,0011,0011,0011,0011,00
Edge distanceccr,N[mm]
1,501,501,501,501,501,501,50
Spacingscr,N[mm]
3,003,003,003,003,003,003,00
CONCRETE SPLITTING FAILURE
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
SHEAR LOAD
R-STUDS Metric Threaded Rods - Steel Class 5.8
Characteristic resistance without lever armVRk,s[kN]
9,0014,0021,0039,0061,0088,00140,00
Ductility factork7[-]
1,01,01,01,01,01,01,0
Characteristic resistance with lever armMRk,s[Nm]
19,0037,0065,00166,00324,00561,001124,00
Partial safety factorγMS[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistance without lever armVRk,s[kN]
15,0023,0034,0063,0098,00141,00224,00
Ductility factork7[-]
1,01,01,01,01,01,01,0
Characteristic resistance with lever armMRk,s[Nm]
30,0060,00105,00266,00519,00898,001799,00
Partial safety factorγMS[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistance without lever armVRk,s[kN]
13,0020,0029,0055,0086,00124,00196,00
Ductility factork7[-]
1,01,01,01,01,01,01,0
Characteristic resistance with lever armMRk,s[Nm]
26,0052,0092,00233,00454,00786,001574,00
Partial safety factorγMS[-]
1,561,561,561,561,561,561,56
CONCRETE PRY-OUT FAILURE
Factork[-]
2,002,002,002,002,002,002,00
Installation safety factorγ2[-]
1,001,001,001,001,001,001,00
CONCRETE EDGE FAILURE
Anchor diameterdnom[mm]
8,0010,0012,0016,0020,0024,0030,00
Effective embedment depthhef[mm]
min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)min(300; hef;12dnom)
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
SizeM8M10M12M16M20M24M30
TENSION LOAD FOR SEISMIC C1
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistanceNRk,s,C1[kN]
18,0029,0042,0078,00122,00176,00280,00
Partial safety factorγMsN,seisC1[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistanceNRk,s,C1[kN]
29,0046,0067,00126,00196,00282,00448,00
Partial safety factorγMsN,seisC1[-]
1,501,501,501,501,501,501,50
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistanceNRk,s,C1[kN]
25,0040,0059,00109,00171,00247,00392,00
Partial safety factorγMsN,seisC1[-]
1,871,871,871,871,871,871,87
COMBINED PULL-OUT AND CONCRETE CONE FAILURE
WORKING LIFE 50 YEARS
Characteristic bond resistance (40°C/24°C)τRk,C1[N/mm2]
6,007,006,507,006,005,505,00
Characteristic bond resistance (80°C/50°C)τRk,C1[N/mm2]
5,006,505,506,005,505,003,50
WORKING LIFE 100 YEARS
Characteristic bond resistance (40°C/24°C)τRk,C1[N/mm2]
6,007,006,006,506,005,504,00
Characteristic bond resistance (80°C/50°C)τRk,C1[N/mm2]
5,006,505,506,005,505,003,50
Installation safety factorγinst[-]
1,001,001,001,001,001,001,00
SHEAR LOAD FOR SEISMIC C1
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistance without lever armVRk,s,C1[kN]
6,3010,1014,7027,3042,7061,6098,00
Partial safety factorγMsV,seisC1[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistance without lever armVRk,s,C1[kN]
10,2016,1023,5044,1068,6098,70156,80
Partial safety factorγMsV,seisC1[-]
1,251,251,251,251,251,251,25
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistance without lever armVRk,s,C1[kN]
9,1014,4020,7038,5059,9086,50137,40
Partial safety factorγMsV,seisC1[-]
1,561,561,561,561,561,561,56
SizeM12M16M20M24
TENSION LOAD FOR SEISMIC C2
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistanceNRk,s,C2[kN]
42,0078,00122,00176,00
Partial safety factorγMsN,seisC2[-]
1,501,501,501,50
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistanceNRk,s,C2[kN]
67,00126,00196,00282,00
Partial safety factorγMsN,seisC2[-]
1,501,501,501,50
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistanceNRk,s,C2[kN]
59,00109,00171,00247,00
Partial safety factorγMsN,seisC2[-]
1,871,871,871,87
COMBINED PULL-OUT AND CONCRETE CONE FAILURE
Characteristic bond resistance (40°C/24°C)τRk,C2[N/mm2]
5,653,935,183,65
Characteristic bond resistance (80°C/50°C)τRk,C2[N/mm2]
5,033,504,613,25
Installation safety factorγinst[-]
1,001,001,001,00
SHEAR LOAD FOR SEISMIC C2
STEEL FAILURE; STEEL CLASS 5.8
Characteristic resistance without lever armVRk,s,C2[kN]
11,6013,7026,3047,00
Partial safety factorγMsV,seisC2[-]
1,251,251,251,25
STEEL FAILURE; STEEL CLASS 8.8
Characteristic resistance without lever armVRk,s,C2[kN]
18,5022,0042,1075,10
Partial safety factorγMsV,seisC2[-]
1,251,251,251,25
STEEL FAILURE; STEEL GRADE A4-70
Characteristic resistance without lever armVRk,s,C2[kN]
15,8019,2036,9066,00
Partial safety factorγMsV,seisC2[-]
1,561,561,561,56

Approvals and publications

Technical library

(20)

Technical assessments(5)

ETA-21/0244 (2023-09-27)

R-KEX-II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

ETA-13/0585 (2023-09-25)

R-KEX-II - Post-installed rebar connections with mortar

UKTA-0836-22/6132 (2022-09-26)

R-KEX-II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

UKTA-0836-22/6109 (2022-05-31)

R-KEX-II - Post-installed rebar connections with injection mortar

KOT_2018_0134

IBDiM-KOT-2018/0134w2

Declarations(5)

DoP-21/0244 R-KEX-II - ETA-21/0244 (2023-09-27)

R-KEX-II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

DoP-13/0585 R-KEX-II - ETA-13/0585 (2023-09-25)

R-KEX-II - Post-installed rebar connections with mortar

UKTA-DoP-22/6132-R-KEXII - UKTA-0836-22/6132 (2022-09-26)

R-KEX-II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

UKTA-DoP-22/6109-R-KEXII - UKTA-0836-22/6109 (2022-05-31)

R-KEX-II - Post-installed rebar connections with injection mortar

KDWU_2018_0134_1

KDWU-2018-0134-2-SYSTEM RAWLPLUG

Certificates(6)

1488-CPR-0944/W - ETA-21/0244 (2023-09-27)

R-KEX-II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

1488-CPR-0737/W - ETA-13/0585 (2023-09-25)

R-KEX-II - Post-installed rebar connections with mortar

UK 0836-CPR-23/P6744 - UKTA-0836-22/6132 (2022-09-26)

R-KEX-II - Bonded fasteners with threaded rod, rod with inner thread and rebar for use in concrete.

UK 0836-CPR-23/P6743 - UKTA-0836-22/6109 (2022-05-31)

R-KEX-II - Post-installed rebar connections with injection mortar

UWB_IBDiM_KOT_2018_0134w2_2018_04_18_2023_07_10_

020-UWB-3059/W

EPD - 01-07/2025 - R-KEX-II (2025-07-23)

R-KEX-II - Type III environmental declaration certificate

Documents(4)

MSDS R-KEX-II (2023-03-01)

R-KEX-II - Bonded fasteners for use in concrete

Hygienic Certificate - R-KEX-II (2023-09-25)

Pure epoxy bonded anchor for professional use with threaded rods and rebar connections.

VOC Emission Test Report - R-KEX-II (2023-09-27)

R-KEX-II - Bonded fasteners for use in concrete

09092025-R-KEXII - Fire resistance

R-KEXII – Statement of essential characteristics under fire exposure for structural anchorages with post-installed reinforcing bars.

Catalogues and product cards

(7)

Product cards(4)

Product card

Product card

Product card

Product card R-KEX-II

Catalogues(3)

Catalogue Offer (overview) - EN

Specification Design Guide

General Catalogue EN 2026/27

Stay up to date

Sign up for our newsletter and don't miss:

Information

on our products and services

News

on the offering and latest promotions

Reports

on events, trade shows and industry conferences

© 2026 Koelner Rawlplug IP